ترغب بنشر مسار تعليمي؟ اضغط هنا

Dosimetry and calorimetry performance of a scientific CMOS camera for environmental monitoring

107   0   0.0 ( 0 )
 نشر من قبل Alexander Deisting Dr
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

This paper explores the prospect of CMOS devices to assay lead in drinking water, using calorimetry. Lead occurs together with traces of radioisotopes, e.g. Lead-210, producing $gamma$-emissions with energies ranging from 10 keV to several 100 keV when they decay; this range is detectable in silicon sensors. In this paper we test a CMOS camera (Oxford Instruments Neo 5.5) for its general performance as a detector of x-rays and low energy $gamma$-rays and assess its sensitivity relative to the World Health Organization upper limit on lead in drinking water. Energies from 6 keV to 60 keV are examined. The CMOS camera has a linear energy response over this range and its energy resolution is for the most part slightly better than 2 %. The Neo sCMOS is not sensitive to x-rays with energies below $sim!!10 keV$. The smallest detectable rate is 40$pm$3 mHz, corresponding to an incident activity on the chip of 7$pm$4 Bq. The estimation of the incident activity sensitivity from the detected activity relies on geometric acceptance and the measured efficiency vs. energy. We report the efficiency measurement, which is 0.08$pm$0.02 % (0.0011$pm$0.0002 %) at 26.3 keV (59.5 keV). Taking calorimetric information into account we measure a minimal detectable rate of 4$pm$1 mHz (1.5$pm$0.1 mHz) for 26.3 keV (59.5 keV) $gamma$-rays, which corresponds to an incident activity of 1.0$pm$0.6 Bq (57$pm$33 Bq). Toy Monte Carlo and Geant4 simulations agree with these results. These results show this CMOS sensor is well-suited as a $gamma$- and x-ray detector with sensitivity at the few to 100 ppb level for Lead-210 in a sample.

قيم البحث

اقرأ أيضاً

Artificially-grown diamond crystals have unique properties that make them suitable as solid-state particle detectors and dosimeters in high-radiation environments. We have been using sensors based on single-crystal diamond grown by chemical vapour de position for dosimetry and beam-loss monitoring at the SuperKEKB collider. Here we describe the assembly and the suite of test and calibration procedures adopted to characterise the diamond-based detectors of this monitoring system. We report the results obtained on 28 detectors and assess the stability and uniformity of response of these devices.
97 - SeokHee Park 2018
The Belle II experiment has just started, searching for physics beyond the Standard Model in $B$, charm and $tau$ decays using data with the integrated luminosity goal of $50 ~mathrm{ab}^{-1}$. Before the physics run with full detector system being i nstalled, Belle II Phase 2 run is on-going at the time of the conference, until July 2018. In this presentation, we describe the environmental monitoring system with an emphasis on the software tools to help the experts and the non-expert shifters who operate the experiment. The monitoring tools are prepared on the control room especially for the shift-takers. It consists of thre components: the monitoring GUI, the alarm system, and the archiver. The monitoring GUI shows the current state of the detector and the alarm system generate warning states from monitored variables with sound and email notification. The archiver is collecting data on single server and provide collected data to the experimental collaborators.
Charged particle therapy (CPT) is an advanced modality of radiation therapy which has grown rapidly worldwide, driven by recent developments in technology and methods of delivery. To ensure safe and high quality treatments, various instruments are us ed for a range of different measurements such as for quality assurance, monitoring and dosimetry purposes. With the emergence of new and enhanced delivery techniques, systems with improved capabilities are needed to exceed existing performance limitations of conventional tools. The Medipix3 is a hybrid pixel detector able to count individual protons with millisecond time resolution at clinical flux with near instant readout and count rate linearity. The system has previously demonstrated use in medical and other applications, showing wide versatility and potential for particle therapy. In this work we present measurements of the Medipix3 detector in the 60 MeV ocular proton therapy beamline at the Clatterbridge Cancer Centre, UK. The beam current and lateral beam profiles were evaluated at multiple positions in the treatment line and compared with EBT3 Gafchromic film. The recorded count rate linearity and temporal analysis of the beam structure was measured with Medipix3 across the full range of available beam intensities, up to $3.12 times 10^{10}$ protons/s. We explore the capacity of Medipix3 to provide non-reference measurements and its applicability as a tool for dosimetry and beam monitoring for CPT. This is the first known time the performance of the Medipix3 detector technology has been tested within a clinical, high proton flux environment.
An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$;$sr and that the detection efficiency and angular resolution for 662$;$keV gamma rays from the center of the FoV is $(9.31 pm 0.95) times 10^{^-5}$ and $5.9^{circ} pm 0.6^{circ}$, respectively. Furthermore, the ETCC can detect 0.15$;murm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$sigma$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.
We present a study of a CMOS test sensor which has been designed, fabricated and characterised to investigate the parameters required for a binary readout electromagnetic calorimeter. The sensors were fabricated with several enhancements in addition to standard CMOS processing. Detailed simulations and experimental results of the performance of the sensor are presented. The sensor and pixels are shown to behave in accordance with expectations and the processing enhancements are found to be essential to achieve the performance required.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا