Spectrum-free integrated photonic remote molecular identification and sensing

224   0   0.0 ( 0 )
 نشر من قبل Ross Cheriton
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Absorption spectroscopy is widely used in sensing and astronomy to understand molecular compositions on microscopic to cosmological scales. However, typical dispersive spectroscopic techniques require multichannel detection, fundamentally limiting the ability to detect extremely weak signals when compared to direct photometric methods. We report the realization of direct spectral molecular detection using a silicon nanophotonic waveguide resonator, obviating dispersive spectral acquisition. We use a thermally tunable silicon ring resonator with a transmission spectrum matched and cross-correlated to the quasi-periodic vibronic absorption lines of hydrogen cyanide. We show that the correlation peak amplitude is proportional to the number of overlapping ring resonances and gas lines, and that molecular specificity is obtained from the phase of the correlation signal in a single detection channel. Our results demonstrate on-chip correlation spectroscopy that is less restricted by the signal-to-noise penalty of other spectroscopic approaches, enabling the detection of faint spectral signatures.

قيم البحث

اقرأ أيضاً

A photonic integrated circuit comprised of an 11 cm multimode speckle waveguide, a 1x32 splitter, and a linear grating coupler array is fabricated and utilized to receive 2 GHz of RF signal bandwidth from 2.5 to 4.5 GHz using a 35 MHz mode locked laser.
We present a modified commercial L-4C geophone with interferometric readout that demonstrated a resolution 60 times lower than the included coil-magnet readout at low frequencies. The intended application for the modified sensor is in vibration isola tion platforms that require improved performance at frequencies lower than 1 Hz. A controls and noise-model of an Advanced LIGO HAM-ISI vibration isolation system was developed, and it shows that our sensor can reduce the residual vibration by a factor of 70 at 0.1 Hz
Triple junction (InGaP/GaAs/Ge) and single junction (SJ) solar cells were irradiated with electrons, protons and neutrons. The degradation of remaining factors was analyzed as function of the induced Displacement Damage Dose (DDD) calculated by means of the SR-NIEL (Screened Relativistic Non Ionizing Energy Loss) approach. In particular, the aim of this work is to analyze the variation of the solar cells remaining factors due to neutron irradiation with respect to those previously obtained with electrons and protons. The current analysis confirms that the degradation of the $P_{max}$ electrical parameter is related by means of the usual semi-empirical expression to the displacement dose, independently of type of the incoming particle. $I_{sc}$ and $V_{oc}$ parameters were also measured as a function of the displacement damage dose. Furthermore, a DLTS analysis was carried out on diodes - with the same epitaxial structure as the middle sub-cell - irradiated with neutrons.
At CEILAP (CITEDEF-CONICET), a multiangle LIDAR is under development to monitor aerosol extinction coefficients in the frame of the CTA (Cherenkov Telescope Array) Project. This is an initiative to build the next generation of ground-based instrument s to collect very high energy gamma-ray radiation (>10 GeV). The atmospheric conditions are very important for CTA observations, and LIDARs play an important role in the measurement of the aerosol optical depth at any direction. The LIDAR being developed at CEILAP was conceived to operate in harsh environmental conditions during the shifts, and these working conditions may produce misalignments. To minimize these effects, the telescopes comprising the reception unit are controlled by a self-alignment system. This paper describes the self-alignment method and hardware automation.
A spectral decomposition method has been adapted to identify and quantify isotopic source terms in high resolution gamma-ray spectroscopy in scenarios with static geometry and shielding. Monte-Carlo simulations were used to build the response matrix of a shielded high purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared to decay corrected values from the calibration certificate. For most nuclei in the standard ($^{241}$Am, $^{109}$Cd, $^{137}$Cs, and $^{60}$Co) the deviations from the certificate values were generally no more than $6$% with a few outliers as high as $12$%. For $^{57}$Co the deviations from the standard reached as high as $25$%, driven by the very low statistics of the sources presence in the calibration spectra. Additionally, a full treatment of error propagation for the technique is presented.