ترغب بنشر مسار تعليمي؟ اضغط هنا

Optical properties of YAG:Ce and GGG:Ce scintillation crystals irradiated with a high fluence proton beam

96   0   0.0 ( 0 )
 نشر من قبل Yuri Davydov
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English
 تأليف V. Baranov




اسأل ChatGPT حول البحث

In this paper, we report on the study of the optical properties of YAG:Ce and GGG:Ce garnet crystals after irradiation in a 660~MeV proton beam with a fluence up to 8.9$times$10$^{14}$ protons/cm$^2$. We found that the transparency of both crystals fell by no more than 7% in the region of their own luminescence. The light yield of a YAG:Ce sample, measured one year after irradiation, dropped by about 35%.



قيم البحث

اقرأ أيضاً

The barrel region of the CMS pixel detector will be equipped with ``n-in-n type silicon sensors. They are processed on DOFZ material, use the moderated p-spray technique and feature a bias grid. The latter leads to a small fraction of the pixel area to be less sensitive to particles. In order to quantify this inefficiency prototype pixel sensors irradiated to particle fluences between $4.7times 10^{13}$ and $2.6times 10^{15} Neq$ have been bump bonded to un-irradiated readout chips and tested using high energy pions at the H2 beam line of the CERN SPS. The readout chip allows a non zero suppressed analogue readout and is therefore well suited to measure the charge collection properties of the sensors. In this paper we discuss the fluence dependence of the collected signal and the particle detection efficiency. Further the position dependence of the efficiency is investigated.
93 - A. Baldini , C. Bemporad , F. Cei 2004
The optical properties of LXe in the vacuum ultra violet (VUV), determining the performance of a scintillation calorimeter, are discussed in detail. The available data, measured in a wider spectral region from visible to UV light, and in a large rang e of Xe densities, from gas to liquid, are examined. It is shown that this information can be used for deriving the LXe optical properties in the VUV. A comparison is made with the few direct measurements in LXe for VUV light resulting from the LXe excitation by ionizing particles. A useful relation is obtained which connects the Rayleigh scattering length to the refractive index in LXe.
This paper presents the results of measurements of fluorescing cerium-doped yttrium aluminum garnet crystals after being irradiated by an accelerated electron beam with energy of around 4 MeV. The measurements were performed using the PHIL linear acc elerator at LAL (France). We observe linear dependence of the crystal emission to the electron beam charge and the isotropy of the photon emission. We provide the calibration coefficients of the photon emission depending on the charge of the accelerated electron beam for two crystals originating from two different manufacturers.
We studied electron amplification and light emission from avalanches in oxygen-containing gas mixtures. The mixtures investigated in this work included, among others, CO2 and N2O mixed with Triethylamine (TEA) or N2. Double-Step Parallel Gap (DSPG) m ultipliers and THick Gas Electron Multipliers (THGEM) were investigated. High light yields were measured from CO2+N2 and CO2+TEA, though with different emission spectra. We observed the characteristic wave-length emission of N2 and of TEA and used a polymer wave-length shifter to convert TEA UV-light into the visible spectrum. The results of these measurements indicate the applicability of optical recording of ionizing tracks in a TPC target-detector designed to study the cross section of the 16O(g,a)12C reaction, a central problem in nuclear astrophysics.
55 - M. Calvi , P. Carniti , C. Gotti 2018
Silicon photomultipliers (SiPM) are solid state light detectors with sensitivity to single photons. Their use in high energy physics experiments, and in particular in ring imaging Cherenkov (RICH) detectors, is hindered by their poor tolerance to rad iation. At room temperature the large increase in dark count rate makes single photon detection practically impossible already at 10$^{11}$ cm$^{-2}$ 1-MeV-equivalent neutron fluence. The neutron fluences foreseen by many subdetectors to be operated at the high luminosity LHC range up to 10$^{14}$ cm$^{-2}$ 1-MeV-equivalent. In this paper we present the effects of such high neutron fluences on Hamamatsu and SensL SiPMs of different cell size. The advantage of annealing at high temperature (up to 175 $^{circ}$C) is discussed. We demonstrate that, after annealing, operation at the single photon level with a SiPM irradiated up to 10$^{14}$ cm$^{-2}$ 1-MeV-equivalent neutron fluence is possible at cryogenic temperature (77 K) with a dark count rate below 1~kHz.