ترغب بنشر مسار تعليمي؟ اضغط هنا

Radiation hardness study for the COMET Phase-I electronics

350   0   0.0 ( 0 )
 نشر من قبل Yu Nakazawa
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Radiation damage on front-end readout and trigger electronics is an important issue in the COMET Phase-I experiment at J-PARC, which plans to search for the neutrinoless transition of a muon to an electron. To produce an intense muon beam, a high-power proton beam impinges on a graphite target, resulting in a high-radiation environment. We require radiation tolerance to a total dose of $1.0,mathrm{kGy}$ and $1,mathrm{MeV}$ equivalent neutron fluence of $1.0times10^{12},mathrm{n_{eq},cm^{-2}}$ including a safety factor of 5 over the duration of the physics measurement. The use of commercially-available electronics components which have high radiation tolerance, if such components can be secured, is desirable in such an environment. The radiation hardness of commercial electronic components has been evaluated in gamma-ray and neutron irradiation tests. As results of these tests, voltage regulators, ADCs, DACs, and several other components were found to have enough tolerance to both gamma-ray and neutron irradiation at the level we require.

قيم البحث

اقرأ أيضاً

An experiment to search for mu-e conversion named COMET is being constructed at J-PARC. The experiment will be carried out using a two-stage approach of Phase-I and Phase-II. The data taking system of Phase-I is developed based on common network tech nology. The data taking system consists of two kinds of networks. One is a front-end network. Its network bundles around twenty front-end devices that have a 1-Gb optical network port. And a front-end computer accepts data from the devices via its network. The other is a back-end network that collects all event fragments from the front-end computers using a 10-Gb network. We used a low price 1Gb/10Gb optical network switch for the front-end network. And direct connection between the front-end PC and an event building PC using 10-Gb optical network devices was used for the back-end network. The event building PC has ten 10-Gb network ports. And each network port of the event building PC is connected to the front-end PCs port without using a network switch. We evaluated data taking performance with an event building on these two kinds of networks. The event building throughput of the front-end network achieved 337 MiB/s. And the event building throughput of the back-end networks achieved 1.2 GiB/s. It means that we could reduce the construction cost of the data taking network using this structure without deteriorating performance. Moreover, we evaluated the writing speed of the local storage RAID disk system connected to a back-end PC by a SAS interface, and a long-distance network copy from the experiment location to the lasting storage.
This paper is devoted to the study of a degradation of CsI(Tl)crystals scintillation characteristics under irradiation with gamma-quanta at the uniformly distributed absorbed dose up to 3700 rad. The sample set consisted of 25 crystals of 30 cm long having a truncated pyramid shape and 30 rectangular crystals of the same length. A large difference in the light output deterioration caused by the radiation was observed for the samples of the same shape. A substantial dependence of the average light output loss from the sample shape is seen as well. On the other hand, the crystals from the same ingot behave very similarly under irradiation.
The Technical Design for the COMET Phase-I experiment is presented in this paper. COMET is an experiment at J-PARC, Japan, which will search for neutrinoless conversion of muons into electrons in the field of an aluminium nucleus ($mu-e$ conversion, $mu^- N to e^- N$); a lepton flavor violating process. The experimental sensitivity goal for this process in the Phase-I experiment is $3.1times10^{-15}$, or 90 % upper limit of branching ratio of $7times 10^{-15}$, which is a factor of 100 improvement over the existing limit. The expected number of background events is 0.032. To achieve the target sensitivity and background level, the 3.2 kW 8 GeV proton beam from J-PARC will be used. Two types of detectors, CyDet and StrECAL, will be used for detecting the mue conversion events, and for measuring the beam-related background events in view of the Phase-II experiment, respectively. Results from simulation on signal and background estimations are also described.
This paper discusses a parallelized event reconstruction of the COMET Phase-I experiment. The experiment aims to discover charged lepton flavor violation by observing 104.97 MeV electrons from neutrinoless muon-to-electron conversion in muonic atoms. The event reconstruction of electrons with multiple helix turns is a challenging problem because hit-to-turn classification requires a high computation cost. The introduced algorithm finds an optimal seed of position and momentum for each turn partition by investigating the residual sum of squares based on distance-of-closest-approach (DCA) between hits and a track extrapolated from the seed. Hits with DCA less than a cutoff value are classified for the turn represented by the seed. The classification performance was optimized by tuning the cutoff value and refining the set of classified hits. The workload was parallelized over the seeds and the hits by defining two GPU kernels, which record track parameters extrapolated from the seeds and finds the DCAs of hits, respectively. A reasonable efficiency and momentum resolution was obtained for a wide momentum region which covers both signal and background electrons. The event reconstruction results from the CPU and GPU were identical to each other. The benchmarked GPUs had an order of magnitude of speedup over a CPU with 16 cores while the exact speed gains varied depending on their architectures.
In this work we study the performance of silicon photomultiplier (SiPM) light sensors after exposure to the JULIC cyclotron proton beam, of energy $sim$ 39 MeV, relative to their performance before exposure. The SiPM devices used in this study show a significant change in their behavior and downward shift of their breakdown voltage by as much as $sim$ 0.4$pm$0.1 V. Single photon measurements appear to be no longer possible for the SiPMs under study after exposure to a dose of $sim$ 0.2 Gy (corresponding to an integrated proton flux of $sim$$phi_{p}$=1.06x10$^{8}$ p/cm$^{2}$). No visible damage to the surface of the devices was caused by the exposure.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا