ترغب بنشر مسار تعليمي؟ اضغط هنا

A Coincidence Velocity Map Imaging Spectrometer for Ions and High-Energy Electrons to Study Inner-Shell Photoionization of Gas-Phase Molecules

140   0   0.0 ( 0 )
 نشر من قبل Utuq Ablikim
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We report on the design and performance of a double-sided coincidence velocity map imaging spectrometer optimized for electron-ion and ion-ion coincidence experiments studying inner-shell photoionization of gas-phase molecules with soft X-ray synchrotron radiation. The apparatus employs two microchannel plate detectors equipped with delay-line anodes for coincident, time- and position-resolved detection of photo- and Auger electrons with kinetic energies up to 300,eV on one side of the spectrometer and photoions up to 25,eV per unit charge on the opposite side. We demonstrate its capabilities by measuring valence photoelectron and ion spectra of neon and nitrogen, and by studying channel-resolved photoelectron and Auger spectra along with fragment-ion momentum correlations for chlorine $2p$ inner-shell ionization of textit{cis}- and textit{trans}-1,2-dichloroethene.



قيم البحث

اقرأ أيضاً

We present a compact design for a velocity-map imaging spectrometer for energetic electrons and ions. The standard geometry by Eppink and Parker [A. T. J. B. Eppink and D. H. Parker, Rev. Sci. Instrum. 68, 3477 (1997)] is augmented by just two extend ed electrodes so as to realize an additional einzel lens. In this way, for a maximum electrode voltage of 7 kV we experimentally demonstrate imaging of electrons with energies up to 65 eV. Simulations show that energy acceptances of <270 and <1,200 eV with an energy resolution of dE / E <5% are achievable for electrode voltages of <20 kV when using diameters of the position-sensitive detector of 42 and 78 mm, respectively.
We report on the design, commissioning, and initial measurements of a Transition-edge Sensor (TES) x-ray spectrometer for the Electron Beam Ion Trap (EBIT) at the National Institute of Standards and Technology (NIST). Over the past few decades, the N IST EBIT has produced numerous studies of highly charged ions in diverse fields such as atomic physics, plasma spectroscopy, and laboratory astrophysics. The newly commissioned NIST EBIT TES Spectrometer (NETS) improves the measurement capabilities of the EBIT through a combination of high x-ray collection efficiency and resolving power. NETS utilizes 192 individual TES x-ray microcalorimeters (166/192 yield) to improve upon the collection area by a factor of ~30 over the 4-pixel neutron transmutation doped germanium-based microcalorimeter spectrometer previously used at the NIST EBIT. The NETS microcalorimeters are optimized for the x-ray energies from roughly 500 eV to 8,000 eV and achieve an energy resolution of 3.7 eV to 5.0 eV over this range, a more modest (<2X) improvement over the previous microcalorimeters. Beyond this energy range NETS can operate with various trade-offs, the most significant of which are reduced efficiency at lower energies and being limited to a subset of the pixels at higher energies. As an initial demonstration of the capabilities of NETS, we measured transitions in He-like and H-like O, Ne, and Ar as well as Ni-like W. We detail the energy calibration and data analysis techniques used to transform detector counts into x-ray spectra, a process that will be the basis for analyzing future data.
We present R-matrix calculations of photoabsorption and photoionization cross sections across the K edge of the Li-like to Ca-like ions stages of Ni. Level-resolved, Breit-Pauli calculations were performed for the Li-like to Na-like stages. Term-reso lved calculations, which include the mass-velocity and Darwin relativistic corrections, were performed for the Mg-like to Ca-like ion stages. This data set is extended up to Fe-like Ni using the distorted wave approximation as implemented by AUTOSTRUCTURE. The R-matrix calculations include the effects of radiative and Auger dampings by means of an optical potential. The damping processes affect the absorption resonances converging to the K thresholds causing them to display symmetric profiles of constant width that smear the otherwise sharp edge at the K-shell photoionization threshold. These data are important for the modeling of features found in photoionized plasmas.
A compact liquid organic neutron spectrometer (CLONS) based on a single NE213 liquid scintillator (5 cm diam. x 5 cm) is described. The spectrometer is designed to measure neutron fluence spectra over the energy range 2-200 MeV and is suitable for us e in neutron fields having any type of time structure. Neutron fluence spectra are obtained from measurements of two-parameter distributions (counts versus pulse height and pulse shape) using the Bayesian unfolding code MAXED. Calibration and test measurements made using a pulsed neutron beam with a continuous energy spectrum are described and the application of the spectrometer to radiation dose measurements is discussed.
90 - A. Hans 2019
The coincident detection of particles is a powerful method in experimental physics, enabling the investigation of a variety of projectile-target interactions. The vast majority of coincidence experiments is performed with charged particles, as they c an be guided by electric or magnetic fields to yield large detection probabilities. When a neutral species or a photon is one of the particles recorded in coincidence, its detection probability typically suffers from small solid angles. Here, we present two optical assemblies considerably enhancing the solid angle for EUV to VIS photon detection. The efficiency and versatility of these assemblies is demonstrated for electron-photon coincidence detection, where electrons and photons emerge from fundamental processes after photoexcitation of gaseous samples by synchrotron radiation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا