In this white paper, we present the scientific cases for adding narrowband optical filters to the Large Synoptic Survey Telescope (LSST). LSST is currently planning to observe the southern sky in 6 broadband optical filters. Three of the four LSST science themes would benefit from adding narrowband filter observations. We discuss the technical considerations of using narrowband filters with the LSST and lay out the scientific impact that would result on the study of AGB stars, emission line nebula (e.g., supernova remnants and planetary nebulae), photometric redshifts of galaxies, and the determination of stellar parameters.

قيم البحث

اقرأ أيضاً

High redshift star-forming galaxies are discovered routinely through a flux excess in narrowband filters (NB) caused by an emission line. In most cases, the width of such filters is broad compared to typical line widths, and the throughput of the fil ters varies substantially within the bandpass. This leads to substantial uncertainties in redshifts and fluxes that are derived from the observations with one specific NB. In this work we demonstrate that the uncertainty in measured line parameters can be sharply reduced by using repeated observations of the same target field with filters that have slightly different transmittance curves. Such data are routinely collected with some large field imaging cameras that use multiple detectors and a separate filter for each of the detectors. An example is the NB118 data from ESOs VISTA InfraRed CAMera (VIRCAM). We carefully developed and characterized this method to determine more accurate redshift and line flux estimates from the ratio of apparent fluxes measured from observations in different narrowband filters and several matching broadband filters. Then, we tested the obtainable quality of parameter estimation both on simulated and actual observations for the example of Ha in the VIRCAM NB118 filters combined with broadband data in Y, J, H. We find that by using this method, the errors in the measured lines fluxes can be reduced up to almost an order of magnitude and that an accuracy in wavelength of better than 1nm can be achieved with the ~13nm wide NB118 filters.
The Wide-Field Infrared Survey Telescope (WFIRST) is expected to launch in the mid-2020s. With its wide-field near-infrared (NIR) camera, it will survey the sky to unprecedented detail. As part of normal operations and as the result of multiple expec ted dedicated surveys, WFIRST will produce several relatively wide-field (tens of square degrees) deep (limiting magnitude of 28 or fainter) fields. In particular, a planned supernova survey is expected to image 3 deep fields in the LSST footprint roughly every 5 days over 2 years. Stacking all data, this survey will produce, over all WFIRST supernova fields in the LSST footprint, ~12-25 deg^2 and ~5-15 deg^2 regions to depths of ~28 mag and ~29 mag, respectively. We suggest LSST undertake mini-surveys that will match the WFIRST cadence and simultaneously observe the supernova survey fields during the 2-year WFIRST supernova survey, achieving a stacked depth similar to that of the WFIRST data. We also suggest additional observations of these same regions throughout the LSST survey to get deep images earlier, have long-term monitoring in the fields, and produce deeper images overall. These fields will provide a legacy for cosmology, extragalactic, and transient/variable science.
The interaction of non-monochromatic radiation with two types of arrays comprising both plasmonic and dielectric nanoparticles has been studied in detail. We have shown that dielectric nanoparticle arrays provide a complete selective reflection of an incident plane wave within a narrow spectral line of collective lattice resonance with a Q-factor of $10^3$ or larger, whereas plasmonic refractory TiN and chemically stable Au nanoparticle arrays demonstrated high-Q resonances with moderate reflectivity. The spectral position of these resonance lines is determined by the lattice period, as well as the size, shape and material composition of the particles. Moreover, the arrays, with fixed dimensional parameters make it possible to fine-tune the position of a selected resonant spectral line by tilting the array relative to the direction of the incident radiation. These effects provide possibilities for engineering of novel selective tunable optical high-Q filters in a wide range of wavelengths: from visible to middle IR. Several highly refractive dielectric nanoparticle materials with low absorption are proposed for various spectral ranges, such as LiNbO$_3$, TiO$_2$, GaAs, Si, and Ge.
The Large Synoptic Survey Telescope (LSST) can advance scientific frontiers beyond its groundbreaking 10-year survey. Here we explore opportunities for extended operations with proposal-based observing strategies, new filters, or transformed instrume ntation. We recommend the development of a mid-decade community- and science-driven process to define next-generation LSST capabilities.
We describe a camera beam simulator for the LSST which is capable of illuminating a 60mm field at f/1.2 with realistic astronomical scenes, enabling studies of CCD astrometric and photometric performance. The goal is to fully simulate LSST observing, in order to characterize charge transport and other features in the thick fully depleted CCDs and to probe low level systematics under realistic conditions. The automated system simulates the centrally obscured LSST beam and sky scenes, including the spectral shape of the night sky. The doubly telecentric design uses a nearly unit magnification design consisting of a spherical mirror, three BK7 lenses, and one beam-splitter window. To achieve the relatively large field the beam-splitter window is used twice. The motivation for this LSST beam test facility was driven by the need to fully characterize a new generation of thick fully-depleted CCDs, and assess their suitability for the broad range of science which is planned for LSST. Due to the fast beam illumination and the thick silicon design [each pixel is 10 microns wide and over 100 microns deep] at long wavelengths there can be effects of photon transport and charge transport in the high purity silicon. The focal surface covers a field more than sufficient for a 40x40 mm LSST CCD. Delivered optical quality meets design goals, with 50% energy within a 5 micron circle. The tests of CCD performance are briefly described.