ترغب بنشر مسار تعليمي؟ اضغط هنا

Optimization of neutron diffraction from phase-gratings

98   0   0.0 ( 0 )
 نشر من قبل Benjamin Heacock
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The recent development of phase-grating moire neutron interferometry promises a wide range of impactful experiments from dark-field imaging of material microstructure to precise measurements of fundamental constants. However, the contrast of 3 % obtained using this moire interferometer was well below the theoretical prediction of 30 % using ideal gratings. It is suspected that non-ideal aspects of the phase-gratings was a leading contributor to this deficiency and that phase-gratings needed to be quantitatively assessed and optimized. Here we characterize neutron diffraction from phase-gratings using Bragg diffraction crystals to determine the optimal phase-grating orientations. We show well-defined diffraction peaks and explore perturbations to the diffraction peaks and the effects on interferometer contrast as a function of grating alignment. This technique promises to improve the contrast of the grating interferometers by providing in-situ aides to grating alignment.

قيم البحث

اقرأ أيضاً

The preparation of neutron-optical phase gratings with light-optical holography is reviewed. We compare the relevant concepts of i) Kogelniks theory for Bragg diffraction of light by thick volume gratings, which can be used to analyze holographic gra tings with both light and neutrons, and ii) the dynamical theory of neutron diffraction. Without going into mathematical detail, we intend to illuminate their correspondence. The findings are illustrated by analyzing data obtained from reconstruction of nanoparticle holographic gratings with both light and neutrons.
We introduce a method for using Fizeau interferometry to measure the intrinsic resolving power of a diffraction grating. This method is more accurate than traditional techniques based on a long-trace profiler (LTP), since it is sensitive to long-dist ance phase errors not revealed by a d-spacing map. We demonstrate 50,400 resolving power for a mechanically ruled XUV grating from Inprentus, Inc.
The use of strongly bent crystals in spectrometers for pulses of a hard x-ray free-electron laser is explored theoretically. Diffraction is calculated in both dynamical and kinematical theories. It is shown that diffraction can be treated kinematical ly when the bending radius is small compared to the critical radius given by the ratio of the Bragg-case extinction length for the actual reflection to the Darwin width of this reflection. As a result, the spectral resolution is limited by the crystal thickness, rather than the extinction length, and can become better than the resolution of a planar dynamically diffracting crystal. As an example, we demonstrate that spectra of the 12 keV pulses can be resolved in 440 reflection from a 20 micron thick diamond crystal bent to a radius of 10 cm.
For holographic gratings recorded in superparamagnetic nanoparticle-polymer composites the diffraction efficiency should -- next to grating spacing, nanoparticle concentration and grating thickness -- depend on the strength of an external magnetic fi eld and the incident neutron spin state. As a consequence, diffraction gratings should be tunable to act as mirrors for one spin state, while being essentially transparent for the other. Thus, polarizing beam splitters for cold neutrons become feasible.
In this paper, we propose the SPR (sparse phase retrieval) method, which is a new phase retrieval method for coherent x-ray diffraction imaging (CXDI). Conventional phase retrieval methods effectively solve the problem for high signal-to-noise ratio measurements, but would not be sufficient for single biomolecular imaging which is expected to be realized with femto-second x-ray free electron laser pulses. The SPR method is based on the Bayesian statistics. It does not need to set the object boundary constraint that is required by the commonly used hybrid input-output (HIO) method, instead a prior distribution is defined with an exponential distribution and used for the estimation. Simulation results demonstrate that the proposed method reconstructs the electron density under a noisy condition even some central pixels are masked.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا