ﻻ يوجد ملخص باللغة العربية
Physical head phantoms allow assessing source reconstruction procedures in electroencephalography and electrical stimulation profiles during transcranial electric stimulation. Volume conduction in the head is strongly influenced by the skull representing the main conductivity barrier. Realistic modeling of its characteristics is thus important for phantom development. In the present study, we proposed plastic clay as a material for modeling the skull in phantoms. We analyzed five clay types varying in granularity and fractions of fireclay, each with firing temperatures from 550 {deg}C to 950 {deg}C. We investigated the conductivity of standardized clay samples when immersed in a 0.9% sodium chloride solution with time-resolved four-point impedance measurements. To test the reusability of the clay model, these measurements were repeated after cleaning the samples by rinsing in deionized water for 5 h. We found time-dependent impedance changes for approximately 5 min after immersion in the solution. Thereafter, the conductivities stabilized between 0.0716 S/m and 0.0224 S/m depending on clay type and firing temperatures. The reproducibility of the measurement results proved the effectiveness of the rinsing procedure. Clay provides formability, is permeable for ions, can be adjusted in conductivity value and is thus suitable for the skull modeling in phantoms.
Whether transcranial direct current stimulation (tDCS) benefits stroke rehabilitation remains unclear. To investigate how tDCS reorganizes brain circuitry, nineteen post-stroke patients underwent rehabilitation sessions with bi-hemispheric real vs sh
Purpose: To develop bone material analogues that can be used in construction of phantoms for simultaneous PET/MRI systems. Methods: Plaster was used as the basis for the bone material analogues tested in this study. It was mixed with varying concen
Transcranial static magnetic stimulation is a novel noninvasive method of reduction of the cortical excitability in certain neurological diseases that, unlike ordinary transcranial magnetic stimulation, makes use of static magnetic fields generated b
Objective: Accurate estimation of SAR is critical to safeguarding vulnerable patients who require an MRI procedure. The increased static field strength and RF duty cycle capabilities in modern MRI scanners mean that systems can easily exceed safe SAR
In several diagnosis and therapy procedures based on electrostimulation effect, the internal physical quantity related to the stimulation is the induced electric field. To estimate the induced electric field in an individual human model, the segmenta