ترغب بنشر مسار تعليمي؟ اضغط هنا

Time-Resolved Measurements of Electron Density in Nanosecond Pulsed Plasmas Using Microwave Scattering

118   0   0.0 ( 0 )
 نشر من قبل Xingxing Wang
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

In this work, Rayleigh microwave scattering was utilized to measure the electron number density produced by nanosecond high voltage breakdown in air between two electrodes in a pin-to-pin configuration (peak voltage 26 kV and pulse duration 55 ns). The peak electron density decreased from 1*10^17 cm^-3 down to 7*10^14 cm^-3 when increasing the gap distance from 2 to 8 mm (total electron number decreased from 2*10^13 down to 5*10^11 respectively). Electron number density decayed on the timescale of about several microseconds due to dissociative recombination.



قيم البحث

اقرأ أيضاً

108 - T. Yong , A.I. Abdalla , 2021
We report on time-resolved measurements of electron number density by continuous-wave laser absorption in a low-energy nanosecond-scale laser-produced spark in atmospheric pressure air. Laser absorption is a result of free-free and bound-free electro n excitation, with the absorption coefficient modeled and evaluated using estimates of the time-variation in electron temperature and probe laser absorption path length. Plasma electron number densities are determined to be as high as $n_text{e}=7times10^{19}$ cm$^{-3}$, and decay to $1/e$ of their peak values over a period of about 50 ns following plasma formation using a 20 mJ, 10 ns pulse width frequency-doubled Nd:YAG laser. The measured plasma densities at later times are shown to be in reasonable agreement with Stark broadening measurements of the 3s[$^5S{^o}$]-3p[$^5P$] electronic transition in atomic oxygen at 777 nm. This study provides support for the use of such continuous wave laser absorption for time resolved electron density measurements in low energy spark discharges in air, provided that an estimate of the electron temperature and laser path length can be made by accompanying diagnostics.
This work proposes a novel method of Thomson microwave scattering for electron number density measurements of miniature plasmas at pressures < 10 Torr. This method is applied to determine electron number density in a positive column of glow discharge initiated at 5 Torr in air with a plasma column diameter of 3.4 mm. The Thomson Microwave Scattering(TMS) system measured the electron number density to be 3.36*10^10 cm^-3. The result obtained using the TMS system was validated against the measurements made using the well-known technique of microwave quarter-wave hairpin resonator. Measurements with the hairpin resonator yielded an electron number density of 2.07*10^10 cm^-3 providing adequate agreement with the TMS system.
72 - A. Hoell , et al 2006
We propose a collective Thomson scattering experiment at the VUV free electron laser facility at DESY (FLASH) which aims to diagnose warm dense matter at near-solid density. The plasma region of interest marks the transition from an ideal plasma to a correlated and degenerate many-particle system and is of current interest, e.g. in ICF experiments or laboratory astrophysics. Plasma diagnostic of such plasmas is a longstanding issue. The collective electron plasma mode (plasmon) is revealed in a pump-probe scattering experiment using the high-brilliant radiation to probe the plasma. The distinctive scattering features allow to infer basic plasma properties. For plasmas in thermal equilibrium the electron density and temperature is determined from scattering off the plasmon mode.
Charge-state-resolved ion energy-time-distributions of pulsed Cu arc plasma were obtained by using direct (time dependent) acquisition of the ion detection signal from a commercial ion mass-per-charge and energy-per-charge analyzer. We find a shift o f energies of Cu2+, Cu3+ and Cu4+ ions to lower values during the first few hundred microseconds after arc ignition, which is evidence for particle collisions in the plasma. The generation of Cu1+ ions in the later part of the pulse, measured by the increase of Cu1+ signal intensity and an associated slight reduction of the mean charge state point to charge exchange reactions between ions and neutrals. At the very beginning of the pulse, when the plasma expands into vacuum and the plasma potential strongly fluctuates, ions with much higher energy (over 200 eV) were observed. Early in the pulse, the ion energies observed are approximately proportional to the ion charge state, and we conclude that the acceleration mechanism is primarily based on acceleration in an electric field. This field is directed away from the cathode, indicative for a potential hump. Measurements by a floating probe suggest that potential structures travel and ions moving in the traveling field can gain high energies up to a few hundred electron-volt. Later in the pulse, the approximate proportionality is lost, which is either related to increased smearing out of different energies due to collisions with neutrals, and/or a change of the acceleration character from electrostatic to gas-dynamic, i.e., dominated by pressure gradient.
In this work, the temporal decay of electrons produced by an atmospheric pin-to-pin nanosecond discharge operating in the spark regime was measured via a combination of microwave Rayleigh scattering (MRS) and laser Rayleigh scattering (LRS). Due to t he initial energy deposition of the nanosecond pulse, a variance in local gas density occurs on the timescale of electron decay. Thus, the assumption of a constant collisional frequency is no longer applicable when electron number data is extracted from the MRS measurements. To recalibrate the MRS measurements throughout the electron decay period, temporally-resolved LRS measurements of the local gas density were performed over the event duration. Local gas density was measured to be 30% of the ambient level during the later stages of electron decay and recovers at about 1 ms after the discharge. A shock front traveling approximately 500 m/s was additionally observed. Coupled with plasma volume calibration via temporally-resolved ICCD imaging, the corrected decay curves of the electron number and electron number density are presented with a measured peak electron number density of 4.5*10^15 cm^-3 and decay rate of ~ 0.1-0.35*10^7 s^-1. A hybrid MRS and LRS diagnostic technique can be applied for a broad spectrum of atmospheric-pressure microplasmas where a variation in number gas density is expected due to an energy deposition in the discharge.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا