ترغب بنشر مسار تعليمي؟ اضغط هنا

Subwavelength Interferometric Control of Absorption in Three-port Acoustic Network

64   0   0.0 ( 0 )
 نشر من قبل Vassos Achilleos A
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Utilizing the effect of losses, we show that symmetric 3-port devices exhibit coherent perfect absorption of waves and we provide the corresponding conditions on the reflection and transmission coefficients. Infinite combinations of asymmetric inputs with different amplitudes and phase at each port as well as a completely symmetric input, are found to be perfectly absorbed. To illustrate the above we study an acoustic 3-port network operating in a subwavelength frequency both theoretically and experimentally. In addition we show how the output from a 3-port network is altered, when conditions of perfect absorption are met but the input waves phase and amplitude vary. In that regard, we propose optimized structures which feature both perfect absorption and perfect transmission at the same frequency by tuning the amplitudes and phases of the input waves.

قيم البحث

اقرأ أيضاً

We demonstrate that the acoustic spin of a first-order Bessel beam can be transferred to a subwavelength (prolate) spheroidal particle at the beam axis in a viscous fluid. The induced radiation torque is proportional to the acoustic spin, which scale s with the beam energy density. The analysis of the particle rotational dynamics in a Stokes flow regime reveals that its angular velocity varies linearly with the acoustic spin. Asymptotic expressions of the radiation torque and angular velocity are obtained for a quasispherical and infinitely thin particle. Excellent agreement is found between the theoretical results of radiation torque and finite element simulations. The induced particle spin is predicted and analyzed using the typical parameter values of the acoustical vortex tweezer and levitation devices. We discuss how the beam energy density and fluid viscosity can be assessed by measuring the induced spin of the particle.
Since S-parameter measurements without uncertainty cannot claim any credibility, the uncertainties in full two-port Vector Network Analyser (VNA) measurements were estimated using total complex differentials (Total Differential Errors). To express pr ecisely a comparison relation between complex differential errors, their differential error regions (DERs) were used. To demonstrate the method in the most accurate case of a direct zero-length thru, practical results are presented for commonly used Z-parameters of a simple, two-port, DC resistive T-network, which was built and tested against frequency with a VNA measurement system extended by two lengthy transmission lines.
336 - Min Yang , Chong Meng , Caixing Fu 2015
We report the experimental realization of perfect sound absorption by sub-wavelength monopole and dipole resonators that exhibit degenerate resonant frequencies. This is achieved through the destructive interference of two resonators transmission res ponses, while the matching of their averaged impedances to that of air implies no backscattering, thereby leading to total absorption. Two examples, both using decorated membrane resonators (DMRs) as the basic units, are presented. The first is a flat panel comprising a DMR and a pair of coupled DMRs, while the second one is a ventilated short tube containing a DMR in conjunction with a sidewall DMR backed by a cavity. In both examples, near perfect absorption, up to 99.7%, has been observed with the airborne wavelength up to 1.2 m, which is at least an order of magnitude larger than the composite absorber. Excellent agreement between theory and experiment is obtained.
The objective was to study uncertainty in antenna input impedance resulting from full one-port Vector Network Analyzer (VNA) measurements. The VNA process equation in the reflection coefficient p of a load, its measurement m and three errors Es -dete rminable from three standard loads and their measurements- was considered. Differentials were selected to represent measurement inaccuracies and load uncertainties (Differential Errors). The differential operator was applied on the process equation and the total differential error dp for any unknown load (Device Under Test DUT) was expressed in terms of dEs and dm, without any simplification. Consequently, the differential error of input impedance Z -or any other physical quantity differentiably dependent on p- is expressible. Furthermore, to express precisely a comparison relation between complex differential errors, the geometric Differential Error Region and its Differential Error Intervals were defined. Practical results are presented for an indoor UHF ground-plane antenna in contrast with a common 50 Ohm DC resistor inside an aluminum box. These two built, unshielded and shielded, DUTs were tested against frequency under different system configurations and measurement considerations. Intermediate results for Es and dEs characterize the measurement system itself. A number of calculations and illustrations demonstrate the application of the method.
An analytical method was developed to estimate errors in quantities depended on full one-port vector network analyser (VNA) measurements using differentials and a complex differential error region (DER) was defined. To evaluate the method, difference s instead of differentials were placed over a DER which was then analysed and compared with another commonly used estimated error. Two real differential error intervals (DEIs) were defined by the greatest lower and least upper bounds of DER projections. To demonstrate the method, a typical device under test (DUT) was built and tested against frequency. Practically, a DER and its DEIs are solely based on manufacturers data for standard loads and their uncertainties, measured values and their inaccuracies.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا