ترغب بنشر مسار تعليمي؟ اضغط هنا

Microwave cavity tuned with liquid metal and its application to Electron Paramagnetic Resonance

81   0   0.0 ( 0 )
 نشر من قبل Nicol\\`o Crescini
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

This note presents a method to tune the resonant frequency $f_{0}$ of a rectangular microwave cavity. This is achieved using a liquid metal, GaInSn, to decrease the volume of the cavity. It is possible to shift $f_{0}$ by filling the cavity with this alloy, in order to reduce the relative distance between the internal walls. The resulting modes have resonant frequencies in the range $7div8,$GHz. The capability of the system of producing an Electron Paramagnetic Resonance (EPR) measurement has been tested by placing a 1 mm diameter Yttrium Iron Garnet (YIG) sphere inside the cavity, and producing a strong coupling between the cavity resonance and Kittel mode. This work shows the possibility to tune a resonant system in the GHz range, which can be useful for several applications.



قيم البحث

اقرأ أيضاً

109 - Mikhail Y. Ivanov 2019
The microwave resonator is one of the key components in the modern Electron Paramagnetic Resonance (EPR) spectroscopy setup, as it largely determines the performance characteristics and limitations of the entire spectrometer. In this research note th e possible way of resonator optimization is described. A detailed computer model describing the distribution of the electromagnetic field for Bruker 4118X-MD-5W1 design resonator has been developed. All details including a dielectric insert, conductive screen, coupling antenna and PTFE supports were included in the model. All dissipation processes were considered in the calculation. The influence of the resonator geometry on the Q-factor, filling factor and operating frequency of the resonant mode has been investigated. The resonator geometric parameters are optimized to achieve maximum sensitivity. According to the calculations, the optimized resonator structure has in 10 times greater sensitivity than the original MD-5 design.
We present a method of broadening the dynamic range of optical interferometric detection of cantilever displacement. The key idea of this system is to use a wavelength-tunable laser source. The wavelength is subject to proportional-integral control, which is used to keep the cavity detuning constant during a measurement. Under this control, the change in wavelength is proportional to the cantilever displacement. Using this technique, we can measure large displacements ($>1 mathrm{mu m}$) without degradation of sensitivity. We apply this technique to high-frequency electron spin resonance spectroscopy and succeed in removing an irregular background signal that arises from the constantly varying sensitivity of the interferometer.
Microwave cavities oscillating in the TM$_{110}$ mode can be used as dynamic electron-optical elements inside an electron microscope. By filling the cavity with a dielectric material it becomes more compact and power efficient, facilitating the imple mentation in an electron microscope. However, the incorporation of the dielectric material makes the manufacturing process more difficult. Presented here are the steps taken to characterize the dielectric material, and to reproducibly fabricate dielectric filled cavities. Also presented are t
100 - D. Lang , J. Doring , T. Norenberg 2017
We introduce a scattering-type scanning near-field infrared microscope (s-SNIM) for the local scale near- field sample analysis and spectroscopy from room (RT) down to liquid helium (LHe) temperatures. The extension of s-SNIM down to T = 5K is in par ticular crucial for low-temperature phase transitions, e.g. for the examination of superconductors, as well as low energy excitations. The LT s-SNIM performance is tested with CO2-IR excitation at T = 7K using a bare Au reference and a structured Si/SiO$_2$-sample. Furthermore, we quantify the impact of local laser heating under the s-SNIM tip apex by monitoring the light-induced ferroelectric-to-paraelectric phase transition of the skyrmion-hosting multiferroic material GaV4S8 at T$_c$ = 42K. We apply LT s-SNIM to study the spectral response of GaV$_4$S$_8$ and its lateral domain structure in the ferroelectric phase by the mid-IR to THz free-electron laser-light source FELBE at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. Notably, our s-SNIM is based on a non-contact atomic force microscope(AFM), and thus can be complemented in-situ by various other AFM techniques, such as topography profiling, piezo-response force microscopy (PFM) and/or Kelvin-probe force microscopy (KPFM). The combination of these methods support the comprehensive study of the mutual interplay in the topographic, electronic and optical properties of surfaces from room temperature down to 5K.
207 - S. Bruenner , D. Cichon , G. Eurin 2020
Long-lived radon daughters are a critical background source in experiments searching for low-energy rare events. Originating from radon in ambient air, radioactive polonium, bismuth and lead isotopes plate-out on materials that are later employed in the experiment. In this paper, we examine cleaning procedures for their capability to remove radon daughters from PTFE surfaces, a material often used in liquid xenon TPCs. We found a large difference between the removal efficiency obtained for the decay chains of $^{222}$Rn and $^{220}$Rn, respectively. This indicates that the plate-out mechanism has an effect on the cleaning success. While the long-lived $^{222}$Rn daughters could be reduced by a factor of ~2, the removal of $^{220}$Rn daughters was up to 10 times more efficient depending on the treatment. Furthermore, the impact of a nitric acid based PTFE cleaning on the liquid xenon purity is investigated in a small-scale liquid xenon TPC.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا