ترغب بنشر مسار تعليمي؟ اضغط هنا

Infrared nanoscopy down to liquid helium temperatures

101   0   0.0 ( 0 )
 نشر من قبل Denny Lang
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We introduce a scattering-type scanning near-field infrared microscope (s-SNIM) for the local scale near- field sample analysis and spectroscopy from room (RT) down to liquid helium (LHe) temperatures. The extension of s-SNIM down to T = 5K is in particular crucial for low-temperature phase transitions, e.g. for the examination of superconductors, as well as low energy excitations. The LT s-SNIM performance is tested with CO2-IR excitation at T = 7K using a bare Au reference and a structured Si/SiO$_2$-sample. Furthermore, we quantify the impact of local laser heating under the s-SNIM tip apex by monitoring the light-induced ferroelectric-to-paraelectric phase transition of the skyrmion-hosting multiferroic material GaV4S8 at T$_c$ = 42K. We apply LT s-SNIM to study the spectral response of GaV$_4$S$_8$ and its lateral domain structure in the ferroelectric phase by the mid-IR to THz free-electron laser-light source FELBE at the Helmholtz-Zentrum Dresden-Rossendorf, Germany. Notably, our s-SNIM is based on a non-contact atomic force microscope(AFM), and thus can be complemented in-situ by various other AFM techniques, such as topography profiling, piezo-response force microscopy (PFM) and/or Kelvin-probe force microscopy (KPFM). The combination of these methods support the comprehensive study of the mutual interplay in the topographic, electronic and optical properties of surfaces from room temperature down to 5K.



قيم البحث

اقرأ أيضاً

Liquid Helium is used widely, from hospitals to characterization of materials at low temperatures. Many experiments at low temperatures require liquid Helium, particularly when vibration isolation precludes the use of cryocoolers and when one needs t o cool heavy equipment such as superconducting coils. Here we describe methods to simplify the operations required to use liquid Helium by eliminating the use of high pressure bottles, avoiding blockage and improving heating and cooling rates. First we show a simple and very low cost method to transfer liquid Helium from a transport container into a cryostat that uses a manual pump having pumping and pressurizing ports, giving a liquid Helium transfer rate of about 100 liters an hour. Second, we describe a closed cycle circuit of Helium gas cooled in an external liquid nitrogen bath that allows precooling a cryogenic experiment without inserting liquid nitrogen into the cryostat, eliminating problems associated to the presence of nitrogen around superconducting magnets. And third, we show a sliding seal assembly and an inner vacuum chamber design that allows inserting large experiments into liquid Helium.
This note presents a method to tune the resonant frequency $f_{0}$ of a rectangular microwave cavity. This is achieved using a liquid metal, GaInSn, to decrease the volume of the cavity. It is possible to shift $f_{0}$ by filling the cavity with this alloy, in order to reduce the relative distance between the internal walls. The resulting modes have resonant frequencies in the range $7div8,$GHz. The capability of the system of producing an Electron Paramagnetic Resonance (EPR) measurement has been tested by placing a 1 mm diameter Yttrium Iron Garnet (YIG) sphere inside the cavity, and producing a strong coupling between the cavity resonance and Kittel mode. This work shows the possibility to tune a resonant system in the GHz range, which can be useful for several applications.
385 - Xavier Audier 2019
We revisit laser intensity noise in the context of stimulated Raman scattering (SRS), which has recently proved to be a key technique to provide label free images of chemical bonds in biological and medical samples. Contrary to most microscopy techni ques, which detect a weak photon flux resulting from light matter interactions, SRS is a pump-probe scheme that works in the high flux regime and happens as a weak modulation ($10^{-4}-10^{-6}$) in a strong laser field. As a result, laser noise is a key issue in SRS detection. This practical tutorial provides the experimentalists with the tools required to assess the amount of noise and the ultimate SRS detection limit in a conventional lock-in-based SRS system. We first define the quantities that are relevant when discussing intensity noise, and illustrate them through a conventional model of light detection by a photodiode. Stimulated Raman Scattering is then introduced in its lock-in-based implementation, and the model presented is adapted in this particular case. The power spectral density (PSD), relative intensity noise (RIN), signal to noise ratio (SNR), and sensitivity of the system are derived and discussed. Two complementary methods are presented that allow measurement of the RIN and assessment of the performance of a SRS system. Such measurements are illustrated on two commercial laser systems. Finally, the consequences of noise in SRS are discussed, and future developments are suggested. The presentation is made simple enough for under-graduated, graduated students, and newcomers in the field of stimulated Raman, and more generally in pump-probe based schemes.
Helium has the lowest boiling point of any element in nature at normal atmospheric pressure. Therefore, any unwanted substance like impurities present in liquid helium will be frozen and will be in solid form. Even if these solid impurities can be ea sily eliminated by filtering, liquid helium may contain a non-negligible quantity of molecular hydrogen. These traces of molecular hydrogen are the causes of a known problem worldwide: the blocking of fine-capillary tubes used as flow impedances in helium evaporation cryostats to achieve temperatures below 4,2K. This problem seriously affects a wide range of cryogenic equipment used in low-temperature physics research and leads to a dramatic loss of time and costs due to the high price of helium. Here, we present first the measurement of molecular hydrogen content in helium gas. Three measures to decrease this molecular hydrogen are afterward proposed; (i) improving the helium quality, (ii) release of helium gas in the atmosphere during purge time for the regeneration cycle of the helium liquefiers internal purifier, and (iii) installation of two catalytic converters in a closed helium circuit. These actions have eliminated our low-temperature impedance blockage occurrences now for more than two years.
204 - G.J. Verbiest , H. Janssen , D. Xu 2019
We developed an impedance bridge that operates at cryogenic temperatures (down to 60 mK) and in perpendicular magnetic fields up to at least 12 T. This is achieved by mounting a GaAs HEMT amplifier perpendicular to a printed circuit board containing the device under test and thereby parallel to the magnetic field. The measured amplitude and phase of the output signal allows for the separation of the total impedance into an absolute capacitance and a resistance. Through a detailed noise characterization, we find that the best resolution is obtained when operating the HEMT amplifier at the highest gain. We obtained a resolution in the absolute capacitance of 6.4~aF$/sqrt{textrm{Hz}}$ at 77 K on a comb-drive actuator, while maintaining a small excitation amplitude of 15~$k_text{B} T/e$. We show the magnetic field functionality of our impedance bridge by measuring the quantum Hall plateaus of a top-gated hBN/graphene/hBN heterostructure at 60~mK with a probe signal of 12.8~$k_text{B} T/e$.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا