ترغب بنشر مسار تعليمي؟ اضغط هنا

Differences in 1D electron plasma wake field acceleration in MeV versus GeV and linear versus blowout regimes

125   0   0.0 ( 0 )
 نشر من قبل David Tsiklauri
 تاريخ النشر 2017
  مجال البحث فيزياء
والبحث باللغة English
 تأليف David Tsiklauri




اسأل ChatGPT حول البحث

In some laboratory and most astrophysical situations plasma wake-field acceleration of electrons is one dimensional, i.e. variation transverse to the beams motion can be ignored. Thus, one dimensional (1D), particle-in-cell (PIC), fully electromagnetic simulations of electron plasma wake field acceleration are conducted in order to study the differences in electron plasma wake field acceleration in MeV versus GeV and linear versus blowout regimes. First, we show that caution needs to be taken when using fluid simulations, as PIC simulations prove that an approximation for an electron bunch not to evolve in time for few hundred plasma periods only applies when it is sufficiently relativistic. This conclusion is true irrespective of the plasma temperature. We find that in the linear regime and GeV energies, the accelerating electric field generated by the plasma wake is similar to the linear and MeV regime. However, because GeV energy driving bunch stays intact for much longer time, the final acceleration energies are much larger in the GeV energies case. In the GeV energy range and blowout regime the wakes accelerating electric field is much larger in amplitude compared to the linear case and also plasma wake geometrical size is much larger. Thus, the correct positioning of the trailing bunch is needed to achieve the efficient acceleration. For the considered case, optimally there should be approximately $(90-100) c/omega_{pe}$ distance between trailing and driving electron bunches in the GeV blowout regime.

قيم البحث

اقرأ أيضاً

64 - David Tsiklauri 2018
Three dimensional particle in cell simulations are used for studying proton driven plasma wake-field acceleration that uses a high-energy proton bunch to drive a plasma wake-field for electron beam acceleration. A new parameter regime was found which generates essentially constant electric field that is three orders magnitudes larger than that of AWAKE design, i.e. of the order of $2 times 10^{3}$ GV/m. This is achieved in the the extreme blowout regime, when number density of the driving proton bunch exceeds plasma electron number density 100 times.
167 - J. Vieira , R.A. Fonseca , 2016
Plasma accelerators can sustain very high acceleration gradients. They are promising candidates for future generations of particle accelerators for several scientific, medical and technological applications. Current plasma based acceleration experime nts operate in the relativistic regime, where the plasma response is strongly non-linear. We outline some of the key properties of wakefield excitation in these regimes. We outline a multidimensional theory for the excitation of plasma wakefields in connection with current experiments. We then use these results and provide design guidelines for the choice of laser and plasma parameters ensuring a stable laser wakefield accelerator that maximizes the quality of the accelerated electrons. We also mention some of the future challenges associated with this technology.
154 - N. Dyakonova , M. Dyakonov , 2020
We study the effect of magnetic field on the properties of a high mobility gated two-dimensional electron gas in a field effect transistor with the Hall bar geometry. When approaching the current saturation when the drain side of the channel becomes strongly depleted, we see a number of unusual effects related to the magnetic field induced re-distribution of the electron density in the conducting channel. The experimental results obtained in the non-linear regime have been interpreted based on the results obtained in the linear regime by a simple theoretical model, which describes quite well our observations.
65 - David Tsiklauri 2016
Three dimensional, particle-in-cell, fully electromagnetic simulations of electron plasma wake field acceleration in the blow out regime are presented. Earlier results are extended by (i) studying the effect of longitudinal density gradient; (ii) avo iding use of co-moving simulation box; (iii) inclusion of ion motion; and (iv) studying fully electromagnetic plasma wake fields. It is established that injecting driving and trailing electron bunches into a positive density gradient of ten-fold increasing density over 10 cm long Lithium vapor plasma, results in spatially more compact and three times larger, compared to the uniform density case, electric fields ($-6.4 times 10^{10}$ V/m), leading to acceleration of the trailing bunch up to 24.4 GeV (starting from initial 20.4 GeV), with an energy transfer efficiencies from leading to trailing bunch of 75 percent. In the uniform density case $-2.5 times 10^{10}$ V/m wake is created leading to acceleration of the trailing bunch up to 22.4 GeV, with an energy transfer efficiencies of 65 percent. It is also established that injecting the electron bunches into a negative density gradient of ten-fold decreasing density over 10 cm long plasma, results in spatially more spread and two-and-half smaller electric fields ($-1.0 times 10^{10}$ V/m), leading to a weaker acceleration of the trailing bunch up to 21.4 GeV, with an energy transfer efficiencies of 45 percent. Inclusion of ion motions into consideration shows that in the plasma wake ion number density can increase over few times the background value. It is also shown that transverse electromagnetic fields in plasma wake are of the same order as the longitudinal (electrostatic) ones.
Different electron acceleration regimes in the evanescent field of a surface plasma wave are studied by considering the interaction of a test electron with the high-frequency electromagnetic field of a surface wave. The non-relativistic and relativis tic limits are investigated. Simple scalings are found demonstrating the possibility to achieve an efficient conversion of the surface wave field energy into electron kinetic energy. This mechanism of electron acceleration can provide a high-frequency pulsed source of relativistic electrons with a well defined energy. In the relativistic limit, the most energetic electrons are obtained in the so-called electromagnetic regime for surface waves. In this regime the particles are accelerated to velocities larger than the wave phase velocity, mainly in the direction parallel to the plasma-vacuum interface.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا