ترغب بنشر مسار تعليمي؟ اضغط هنا

Stimulated X-ray Raman scattering in Free Electron Lasers with incoherent spectrum

83   0   0.0 ( 0 )
 نشر من قبل Gennady Stupakov
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The single-pulse spectrum of self-amplified spontaneous emission (SASE) free electron lasers (FELs) is characterized by random fluctuations in frequency. The typical spectrum bandwidth for a hard x-ray FEL is in the range of 10-20 eV and is comparable with the distance between energy levels of valence electrons in atoms an molecules. We calculate the rate of transitions in a quantum three-level system with the energy difference of several eV caused by such radiation and show that for x-ray intensities in the range of $10^{20}$ W/cm$^2$ the probability of the transition over the duration of the x-ray pulse is large. We argue that this effect can be used to modify the spectrum of a SASE FEL potentially making it more narrow.


قيم البحث

اقرأ أيضاً

We discuss the physics of a microbunched electron beam kicked by the dipole field of a corrector magnet by describing the kinematics of coherent undulator radiation after the kick. Particle tracking shows that the electron beam direction changes afte r the kick, while the orientation of the microbunching wavefront stays unvaried. Therefore, electrons motion and wavefront normal have different directions. Coherent radiation emission in a downstream undulator is expected to be dramatically suppressed as soon as the kick angle becomes larger than the divergence of the output radiation. In fact, according to conventional treatments, coherent radiation is emitted along the normal to the microbunching wavefront. Here we show that kinematics predicts a surprising effect. Namely, a description of coherent undulator radiation in the laboratory frame yields the radical notion that, due light aberration, strong coherent radiation is produced along the direction of the kick. We hold a recent FEL study made at the LCLS as a direct experimental evidence that coherent undulator radiation can be kicked by an angle of about five times the rms radiation divergence without suppression. We put forward our kinematical description of this experiment.
A superconducting linear accelerator operating in continuous-wave mode could produce X-ray free electron lasers (XFEL) at megahertz repetition rate, with the capability that delivering wide spectral range coherent radiation to multi end stations. In this Letter, the energy recovery Linac (ERL) mode is proposed to flexibly control the electron beam energy for a continuous-wave superconducting Linac. Theoretical investigations and multi-dimensional numerical simulations are applied to the Linac case of Shanghai high-repetition-rate XFEL and extreme light facility. The results show that, with ERL operation in the last 25 cryo-modules, the strict requirements on RF power system could be significantly relaxed. And if one exhaust the RF power, the maximum electron beam energy can be enhanced from 8.74 GeV to 11.41GeV in ERL mode. The optimization of the ERL operation, the multi-energy electron beam transport and the XFEL performance improvements are presented.
We study the perspectives of measuring the phenomenon of vacuum birefringence predicted by quantum electrodynamics using an x-ray free-electron laser (XFEL) alone. We devise an experimental scheme allowing the XFEL beam to collide with itself under a finite angle, and thus act as both pump and probe field for the effect. The signature of vacuum birefringence is encoded in polarization-flipped signal photons to be detected with high-purity x-ray polarimetry. Our findings for idealized scenarios underline that the discovery potential of solely XFEL-based setups can be comparable to those involving optical high-intensity lasers. For currently achievable scenarios, we identify several key details of the x-ray optical ingredients that exert a strong influence on the magnitude of the desired signatures.
120 - I. Gadjev , N. Sudar , M. Babzien 2017
The generation of X-rays and {gamma}-rays based on synchrotron radiation from free electrons, emitted in magnet arrays such as undulators, forms the basis of much of modern X-ray science. This approach has the drawback of requiring very high energy, up to the multi-GeV-scale, electron beams, to obtain the required photon energy. Due to the limit in accelerating gradients in conventional particle accelerators, reaching high energy typically demands use of instruments exceeding 100s of meters in length. Compact, less costly, monochromatic X-ray sources based on very high field acceleration and very short period undulators, however, may revolutionize diverse advanced X-ray applications ranging from novel X-ray therapy techniques to active interrogation of sensitive materials, by making them accessible in cost and size. Such compactness may be obtained by an all-optical approach, which employs a laser-driven high gradient accelerator based on inverse free electron laser (IFEL), followed by a collision point for inverse Compton scattering (ICS), a scheme where a laser is used to provide undulator fields. We present an experimental proof-of-principle of this approach, where a TW-class CO2 laser pulse is split in two, with half used to accelerate a high quality electron beam up to 84 MeV through the IFEL interaction, and the other half acts as an electromagnetic undulator to generate up to 13 keV X-rays via ICS. These results demonstrate the feasibility of this scheme, which can be joined with other techniques such as laser recirculation to yield very compact, high brilliance photon sources, extending from the keV to MeV scale. Furthermore, use of the IFEL acceleration with the ICS interaction produces a train of very high intensity X-ray pulses, thus also permitting a unique tool that can be phase-locked to a laser pulse in frontier pump-probe experimental scenarios.
A model of a Free Electron Laser operating with an elliptically polarised undulator is presented. The equations describing the FEL interaction, including resonant harmonic radiation fields, are averaged over an undulator period and generate a general ised Bessel function scaling factor, similar to that of planar undulator FEL theory. Comparison between simulations of the averaged model with those of an unaveraged model show very good agreement in the linear regime. Two unexpected results were found. Firstly, an increased coupling to harmonics for elliptical rather than planar polarisarised undulators. Secondly, and thought to be unrelated to the undulator polarisation, a signficantly different evolution between the averaged and unaveraged simulations of the harmonic radiation evolution approaching FEL saturation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا