ترغب بنشر مسار تعليمي؟ اضغط هنا

KWISP: an ultra-sensitive force sensor for the Dark Energy sector

70   0   0.0 ( 0 )
 نشر من قبل Giovanni Cantatore
 تاريخ النشر 2015
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

An ultra-sensitive opto-mechanical force sensor has been built and tested in the optics laboratory at INFN Trieste. Its application to experiments in the Dark Energy sector, such as those for Chameleon-type WISPs, is particularly attractive, as it enables a search for their direct coupling to matter. We present here the main characteristics and the absolute force calibration of the KWISP (Kinetic WISP detection) sensor. It is based on a thin Si3N4 micro-membrane placed inside a Fabry-Perot optical cavity. By monitoring the cavity characteristic frequencies it is possible to detect the tiny membrane displacements caused by an applied force. Far from the mechanical resonant frequency of the membrane, the measured force sensitivity is 5.0e-14 N/sqrt(Hz), corresponding to a displacement sensitivity of 2.5e-15 m/sqrt(Hz), while near resonance the sensitivity is 1.5e-14 N/sqrt(Hz), reaching the estimated thermal limit, or, in terms of displacement, 7.5e-16 N/sqrt(Hz). These displacement sensitivities are comparable to those that can be achieved by large interferometric gravitational wave detectors.



قيم البحث

اقرأ أيضاً

We present the technical design for the SuperCDMS high-voltage, low-mass dark matter detectors, designed to be sensitive to dark matter down to 300 MeV/$c^2$ in mass and resolve individual electron-hole pairs from low-energy scattering events in high -purity Ge and Si crystals. In this paper we discuss some of the studies and technological improvements which have allowed us to design such a sensitive detector, including advances in phonon sensor design and detector simulation. With this design we expect to achieve better than 10 eV (5 eV) phonon energy resolution in our Ge (Si) detectors, and recoil energy resolution below 1eV by exploiting Luke-Neganov phonon generation of charges accelerated in high fields.
Material screening for identifying low-energy electron emitters and alpha-decaying isotopes is now a prerequisite for rare-event searches (e.g., dark-matter direct detection and neutrinoless double-beta decay) for which surface radiocontamination has become an increasingly important background. The BetaCage, a gaseous neon time-projection chamber, is a proposed ultra-sensitive (and nondestructive) screener for alpha- and beta-emitting surface contaminants to which existing screening facilities are insufficiently sensitive. Sensitivity goals are 0.1 betas per keV-m$^2$-day and 0.1 alphas per m$^2$-day, with the former limited by Compton scattering of photons in the screening samples and (thanks to tracking) the latter expected to be signal-limited; radioassays and simulations indicate backgrounds from detector materials and radon daughters should be subdominant. We report on details of the background simulations and detector design that provide the discrimination, shielding, and radiopurity necessary to reach our sensitivity goals for a chamber with a 95$times$95 cm$^2$ sample area positioned below a 40 cm drift region and monitored by crisscrossed anode and cathode planes consisting of 151 wires each.
Ring laser gyroscopes are top sensitivity inertial sensors used in the measurement of angular rotation rates. It is well known that the response of such remarkable instruments can in principle access the very low frequency band, but the occurrence of nonlinear effects in the laser dynamics imposes severe limitations in terms of sensitivity and stability. We report here general relationships aimed at evaluating corrections able to effectively account for nonlinear laser dynamics. The so-derived corrections are applied to analyse thirty days of continuous operation of the large area ring laser gyroscope GINGERINO leading to duly reconstruct the Sagnac frequency $omega_S$. The analysis shows that, on the average, the evaluated corrections affect the measurement of the Earth rotation rate $Omega_E$ at the level of 1 part in $1.5times10^{3}$. Among the identified corrections, the null shift term $omega_{NS}$ is the dominant one. It turns out proportional to the optical losses $mu$ of the ring cavity, which are changing in time at the level of $10%$ within the considered period of thirty days. The time behaviour is reconstructed based on available signals (interferogram and mono-beam intensities), and the Allan deviation of the estimated $Omega_E$ shows a remarkable long term stability, leading to a sensitivity better than $10^{-10}$rad/s with more than $10$s of integration time, and approaching $(8.5pm 0.5)times 10^{-12}$rad/s with $4.5times10^{5}$s of integration time.
Due to the inverse Primakoff effect it has been shown that when axions interact with a DC magnetic B-field the resulting electrical action will produce an AC electromotive force which oscillates at the Compton frequency of the axion, and may be model ed as an oscillating effective impressed magnetic current boundary source. We use this result to calculate the sensitivity of new experiments to low-mass axions using the quasi-static technique. First, we calculate the current induced in an electric dipole antenna (straight conducting wire) when the DC B-field is spatially constant and show that it has a sensitivity proportional to the axion mass. Following this we extend the topology by making use of the full extent of the spatially varying DC B-field. This extension is achieved by transforming the 1D conducting wire to a 2D winding, to fully link the effective magnetic current boundary source and thus couple to the full axion induced electrical action. In this case the conductor becomes a coil winding where the voltage induced across the winding increases proportionally to the number of windings. We investigate two different topologies: The 1st uses a single winding, and couples to the effective short circuit current generated in the winding, which is read out using a sensitive low impedance SQUID amplifier: The 2nd uses multiple windings, with every turn effectively increasing the the voltage output proportional to the winding number. The read out of this configuration is optimised by implementing a cryogenic low-noise high input impedance voltage amplifier. The end result is a new Broadband Electrical Action Sensing Techniques with orders of magnitude improved sensitivity, which is linearly proportional to the axion photon coupling and capable of detecting QCD dark matter axions.
97 - T. Akutsu , M. Ando , K. Arai 2019
Modern ground-based gravitational wave (GW) detectors require a complex interferometer configuration with multiple coupled optical cavities. Since achieving the resonances of the arm cavities is the most challenging among the lock acquisition process es, the scheme called arm length stabilization (ALS) had been employed for lock acquisition of the arm cavities. We designed a new type of the ALS, which is compatible with the interferometers having long arms like the next generation GW detectors. The features of the new ALS are that the control configuration is simpler than those of previous ones and that it is not necessary to lay optical fibers for the ALS along the kilometer-long arms of the detector. Along with simulations of its noise performance, an experimental test of the new ALS was performed utilizing a single arm cavity of KAGRA. This paper presents the first results of the test where we demonstrated that lock acquisition of the arm cavity was achieved using the new ALS and residual noise was measured to be $8.2,mathrm{Hz}$ in units of frequency, which is smaller than the linewidth of the arm cavity and thus low enough to lock the full interferometer of KAGRA in a repeatable and reliable manner.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا