ترغب بنشر مسار تعليمي؟ اضغط هنا

Effective velocity distribution in an atom gravimeter: effect of the convolution with the response of the detection

221   0   0.0 ( 0 )
 نشر من قبل Franck Pereira Dos Santos
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English
 تأليف Tristan Farah




اسأل ChatGPT حول البحث

We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms free fall, we characterize the effective velocity distribution, ie the velocity distribution of the detected atom, as a function of the laser cooling and trapping parameters. In particular, we show that the response of the detection induces a pronounced asymetry of this effective velocity distribution that depends not only on the imbalance between molasses beams but also on the initial position of the displaced atomic sample. This convolution with the detection has a strong influence on the averaging of the bias due to Coriolis acceleration. The present study allows a fairly good understanding of results previously published in {it Louchet-Chauvet et al., NJP 13, 065025 (2011)}, where the mean phase shift due to Coriolis acceleration was found to have a sign different from expected.

قيم البحث

اقرأ أيضاً

44 - B. Cheng , P. Gillot , S. Merlet 2015
We present here an analysis of the influence of the frequency dependence of the Raman laser light shifts on the phase of a Raman-type atom gravimeter. Frequency chirps are applied to the Raman lasers in order to compensate gravity and ensure the reso nance of the Raman pulses during the interferometer. We show that the change in the Raman light shift when this chirp is applied only to one of the two Raman lasers is enough to bias the gravity measurement by a fraction of $mu$Gal ($1~mu$Gal~=~$10^{-8}$~m/s$^2$). We also show that this effect is not compensated when averaging over the two directions of the Raman wavevector $k$. This thus constitutes a limit to the rejection efficiency of the $k$-reversal technique. Our analysis allows us to separate this effect from the effect of the finite speed of light, which we find in perfect agreement with expected values. This study highlights the benefit of chirping symmetrically the two Raman lasers.
We characterize the performance of a gravimeter and a gravity gradiometer based on the $^{1}$S$_{0}$-$^3$P$_0$ clock transition of strontium atoms. We use this new quantum sensor to measure the gravitational acceleration with a relative sensitivity o f $1.7times10^{-5}$, representing the first realisation of an atomic interferometry gravimeter based on a single-photon transition. Various noise contributions to the gravimeter are measured and characterized, with the current primary limitation to sensitivity seen to be the intrinsic noise of the interferometry laser itself. In a gravity gradiometer configuration, a differential phase sensitivity of 1.53~rad/$sqrt{Hz}$ was achieved at an artificially introduced differential phase of $pi/2$~rad. We experimentally investigated the effects of the contrast and visibility based on various parameters and achieve a total interferometry time of 30~ms, which is longer than previously reported for such interferometers. The characterization and determined limitations of the present apparatus employing $^{88}$Sr atoms provides a guidance for the future development of large-scale clock-transition gravimeters and gravity gradiometers with alkali-earth and alkali-earth-like atoms (e.g., $^{87}$Sr, Ca, Yb).
Precisely evaluating the systematic error induced by the quadratic Zeeman effect is important for developing atom interferometer gravimeters aiming at an accuracy in the regime ( ). This paper reports on the experimental investigation of Raman spectr oscopy-based magnetic field measurements and the evaluation of the systematic error in the Gravimetric Atom Interferometer (GAIN) due to quadratic Zeeman effect. We discuss Raman duration and frequency step size dependent magnetic field measurement uncertainty, present vector light shift (VLS) and tensor light shift (TLS) induced magnetic field measurement offset, and map the absolute magnetic field inside the interferometer chamber of GAIN with an uncertainty of 0.72 nT and a spatial resolution of 12.8 mm. We evaluate the quadratic Zeeman effect induced gravity measurement error in GAIN as . The methods shown in this paper are important for precisely mapping the absolute magnetic field in vacuum and reducing the quadratic Zeeman effect induced systematic error in Raman transition-based precision measurements, such as atomic interferometer gravimeters.
We study theoretically and experimentally the influence of temporally shaping the light pulses in an atom interferometer, with a focus on the phase response of the interferometer. We show that smooth light pulse shapes allow rejecting high frequency phase fluctuations (above the Rabi frequency) and thus relax the requirements on the phase noise or frequency noise of the interrogation lasers driving the interferometer. The light pulse shape is also shown to modify the scale factor of the interferometer, which has to be taken into account in the evaluation of its accuracy budget. We discuss the trade-offs to operate when choosing a particular pulse shape, by taking into account phase noise rejection, velocity selectivity, and applicability to large momentum transfer atom interferometry.
74 - Nicola Malossi 2009
We demonstrate the realization of a new scheme for cold atom gravimetry based on the use of double diffraction beamsplitters recently demonstrated in cite{Leveque}, where the use of two retro-reflected Raman beams allows symmetric diffraction in $pm hbar k_{eff}$ momenta. Though in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneously resonant, we demonstrate that such diffraction pulses can remain efficient on atoms with non zero velocity, such as in a gravimeter, when modulating the frequency of one of the two Raman laser sources. We use such pulses to realize an interferometer insensitive to laser phase noise and some of the dominant systematics. This reduces the technical requirements and would allow the realization of a simple atomic gravimeter. We demonstrate a sensitivity of $1.2times10^{-7}g$ per shot.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا