Sources of Variability in Alpha Emissivity Measurements at LA and ULA Levels, a Multicenter Study

83   0   0.0 ( 0 )
 نشر من قبل Brendan McNally
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English
 تأليف B.D. McNally




اسأل ChatGPT حول البحث

Alpha emissivity measurements are important in the semiconductor industry for assessing the suitability of materials for use in production processes. A recently published round-robin study that circulated the same samples to several alpha counting centers showed wide center-to-center variations in measured alpha emissivity. A separate analysis of these results hypothesized that much of the variation might arise from differences in sample-to-entrance window separations. XIA recently introduced an ultra low background counter, the UltraLo-1800 (UltraLo), that operates in a fundamentally different manner from the proportional counters used at most of the centers in the original study. In particular, by placing the sample within the counting volume, it eliminates the sample-to-entrance window separation issue noted above, and so offers an opportunity to test this hypothesis. In this work we briefly review how the UltraLo operates and describe a new round-robin study conducted entirely on UltraLo instruments using a set of standard samples that included two samples used in the original study. This study shows that, for LA (Low Alpha between 2 and 50 alpha/khr-cm$^2$) sample measurements, the only remaining site-to-site variations were due to counting statistics. Variations in ULA (Ultra-Low Alpha < 2 alpha/khr-cm$^2$) sample measurements were reduced three-fold, compared to the earlier study, with the measurements suggesting that residual activity variations now primarily arise from site-to-site differences in the cosmogenic background.

قيم البحث

اقرأ أيضاً

In the described device, the thermal emissivity or absorptivity of the sample is measured by substitution of the radiative heat flow between two parallel surfaces by thermal output of a heater. Fast measurements of the mutual emissivity for the range of the temperature of the radiating surface 25 K-150 K are possible. The absorbing surface has a temperature between 5 K and 10 K when LHe is used as cryoliquid. The desired measurement sensitivity is 1 mK for temperature and 0.1 {mu}W for heat power, respectively. The diameter of the whole device is 50 mm and so it is possible to use a commercial dewar can for the cooling. The form of the sample is a round plate 40 mm in diameter and 1 mm in thickness with one tested side. The emissivity and its temperature dependency for various surface treatments can be checked immediately before application in a cryogenic system.
In this paper we present the temperature-dependent emissivity of a silicon sample, estimated from its cool-down curve in a constant low temperature environment ($approx$ 82K). The emissivity value follow a linear dependency in the 120-260 K temperatu re range. This result is of great interest to the LIGO Voyager gravitational wave interferometer project since it would mean that no extra high thermal emissivity coating on the test masses would be required in order to cool them down to 123 K. The results presented here indicate that bulk silicon itself can have sufficient thermal emissivity in order to cool the 200 kg LIGO Voyager test masses only by radiation in a reasonable short amount of time (less than a week). However, it is still not clear if the natural emissivity of silicon will be sufficient to maintain the LIGO Voyager test masses at the desired temperature (123 K) while removing power absorbed by the test masses. With the present results, a black coating on the barrel surface of the test masses would be necessary if power in excess of 6 W is delivered. However, the agreement we found between the hemispherical emissivity obtained by a theory of semi-transparent Silicon and the obtained experimental results makes us believe that the LIGO Voyager test masses, because of their dimensions, will have effective emissivities around 0.7, which would be enough to remove about 8.6 W (7.5 W) for a shield at 60 K (80K). This hypothesis may be confirmed in the near future with new measurements.
At the n_TOF experiment at CERN a dedicated single-crystal chemical vapor deposition (sCVD) Diamond Mosaic-Detector has been developed for (n,$alpha$) cross-section measurements. The detector, characterized by an excellent time and energy resolution, consists of an array of 9 sCVD diamond diodes. The detector has been characterized and a cross-section measurement has been performed for the $^{59}$Ni(n,$alpha$)$^{56}$Fe reaction in 2012. The characteristics of the detector, its performance and the promising preliminary results of the experiment are presented.
The discovery of argon from underground sources with significantly less 39Ar than atmospheric argon was an important step in the development of direct-detection dark matter experiments using argon as the active target. We report on the design and ope ration of a low background detector with a single phase liquid argon target that was built to study the 39Ar content of the underground argon. Underground argon from the Kinder Morgan CO2 plant in Cortez, Colorado was determined to have less than 0.65% of the 39Ar activity in atmospheric argon.
During the era of the High Luminosity LHC (HL-LHC) the devices in its experiments will be subjected to increased radiation levels with high fluxes of neutrons and charged hadrons, especially in the inner detectors. A systematic program of radiation t ests with neutrons and charged hadrons is being carried out by the CMS and ATLAS Collaborations in view of the upgrade of the experiments, in order to cope with the higher luminosity at HL-LHC and the associated increase in the pile-up events and radiation fluxes. In this work, results from a complementary radiation study with $^{60}$Co-$gamma$ photons are presented. The doses are equivalent to those that the outer layers of the silicon tracker systems of the two big LHC experiments will be subjected to. The devices in this study are float-zone oxygenated p-type MOS capacitors. The results of CV measurements on these devices are presented as a function of the total absorbed radiation dose following a specific annealing protocol. The measurements are compared with the results of a TCAD simulation.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا