ﻻ يوجد ملخص باللغة العربية
Alpha emissivity measurements are important in the semiconductor industry for assessing the suitability of materials for use in production processes. A recently published round-robin study that circulated the same samples to several alpha counting centers showed wide center-to-center variations in measured alpha emissivity. A separate analysis of these results hypothesized that much of the variation might arise from differences in sample-to-entrance window separations. XIA recently introduced an ultra low background counter, the UltraLo-1800 (UltraLo), that operates in a fundamentally different manner from the proportional counters used at most of the centers in the original study. In particular, by placing the sample within the counting volume, it eliminates the sample-to-entrance window separation issue noted above, and so offers an opportunity to test this hypothesis. In this work we briefly review how the UltraLo operates and describe a new round-robin study conducted entirely on UltraLo instruments using a set of standard samples that included two samples used in the original study. This study shows that, for LA (Low Alpha between 2 and 50 alpha/khr-cm$^2$) sample measurements, the only remaining site-to-site variations were due to counting statistics. Variations in ULA (Ultra-Low Alpha < 2 alpha/khr-cm$^2$) sample measurements were reduced three-fold, compared to the earlier study, with the measurements suggesting that residual activity variations now primarily arise from site-to-site differences in the cosmogenic background.
In the described device, the thermal emissivity or absorptivity of the sample is measured by substitution of the radiative heat flow between two parallel surfaces by thermal output of a heater. Fast measurements of the mutual emissivity for the range
In this paper we present the temperature-dependent emissivity of a silicon sample, estimated from its cool-down curve in a constant low temperature environment ($approx$ 82K). The emissivity value follow a linear dependency in the 120-260 K temperatu
At the n_TOF experiment at CERN a dedicated single-crystal chemical vapor deposition (sCVD) Diamond Mosaic-Detector has been developed for (n,$alpha$) cross-section measurements. The detector, characterized by an excellent time and energy resolution,
The discovery of argon from underground sources with significantly less 39Ar than atmospheric argon was an important step in the development of direct-detection dark matter experiments using argon as the active target. We report on the design and ope
During the era of the High Luminosity LHC (HL-LHC) the devices in its experiments will be subjected to increased radiation levels with high fluxes of neutrons and charged hadrons, especially in the inner detectors. A systematic program of radiation t