ترغب بنشر مسار تعليمي؟ اضغط هنا

Stability Transfer between Two Clock Lasers Operating at Different Wavelengths for Absolute Frequency Measurement of Clock Transition in 87Sr

151   0   0.0 ( 0 )
 نشر من قبل Tetsuya Ido
 تاريخ النشر 2012
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We demonstrated transferring the stability of one highly stable clock laser operating at 729 nm to another less stable laser operating at 698 nm. The two different wavelengths were bridged using an optical frequency comb. The improved stability of the clock laser at 698 nm enabled us to evaluate the systematic frequency shifts of the Sr optical lattice clock with shorter averaging time. We determined the absolute frequency of the clock transition 1S0 - 3P0 in 87Sr to be 429 228 004 229 873.9 (1.4) Hz referenced to the SI second on the geoid via International Atomic Time (TAI).

قيم البحث

اقرأ أيضاً

We present the first characterization of the spectral properties of superradiant light emitted from the ultra-narrow, 1 mHz linewidth optical clock transition in an ensemble of cold $^{87}$Sr atoms. Such a light source has been proposed as a next-gen eration active atomic frequency reference, with the potential to enable high-precision optical frequency references to be used outside laboratory environments. By comparing the frequency of our superradiant source to that of a state-of-the-art cavity-stabilized laser and optical lattice clock, we observe a fractional Allan deviation of $6.7(1)times 10^{-16}$ at 1 second of averaging, establish absolute accuracy at the 2 Hz ($4times 10^{-15}$ fractional frequency) level, and demonstrate insensitivity to key environmental perturbations.
The absolute frequency of the In$^{+}$ $5s^{2 1}S_{0}$ - $5s5p^{3}P_{0}$ clock transition at 237 nm was measured with an accuracy of 1.8 parts in $10^{13}$. Using a phase-coherent frequency chain, we compared the $^{1}S_{0}$ - $^{3}P_{0}$ transition with a methane-stabilized He-Ne laser at 3.39 $mu$m which was calibrated against an atomic cesium fountain clock. A frequency gap of 37 THz at the fourth harmonic of the He-Ne standard was bridged by a frequency comb generated by a mode-locked femtosecond laser. The frequency of the In$^{+}$ clock transition was found to be $1 267 402 452 899.92 (0.23)$ kHz, the accuracy being limited by the uncertainty of the He-Ne laser reference. This represents an improvement in accuracy of more than 2 orders of magnitude on previous measurements of the line and now stands as the most accurate measurement of an optical transition in a single ion.
We report a measurement of the absolute frequency of the 1S0-3P0 transition in the 171Yb optical lattice clock at KRISS (KRISS-Yb1) for 14 months, which was referenced to the SI second by primary and secondary standards worldwide via TAI (Internation al Atomic Time). The determined absolute frequency is 518 295 836 590 863.75(14) Hz with the relative frequency uncertainty of 2.6x10^-16, which agrees well with other reports. This result is expected to contribute to the future update of the CIPM recommendation frequency of the secondary frequency standards.
With the uncertainty of the optical clocks improving to the order of 10-18, the probe light used to detect the clock transition has demonstrated nonnegligible Stark shift, provoking to precisely evaluate this shift. Here, we demonstrate a frequency m odulation technique to realize a large measurement lever arm of the probe Stark shift with no cost of the measurement accuracy of the interleaved stabilization method. This frequency-modulated spectrum is theoretical described and experimental verified. The probe Stark shift coefficient of the 87Sr optical lattice clock is experimentally determined as -(45.97+/-3.51) Hz/(W/cm2) using this frequency modulation spectroscopy.
We report a frequency measurement of the 1S0-3P0 transition of 87Sr atoms in an optical lattice clock. The frequency is determined to be 429 228 004 229 879 (5) Hz with a fractional uncertainty that is comparable to state-of-the-art optical clocks wi th neutral atoms in free fall. Two previous measurements of this transition were found to disagree by about 2x10^{-13}, i.e. almost four times the combined error bar, instilling doubt on the potential of optical lattice clocks to perform at a high accuracy level. In perfect agreement with one of these two values, our measurement essentially dissipates this doubt.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا