ترغب بنشر مسار تعليمي؟ اضغط هنا

Status of COLDDIAG: A Cold Vacuum Chamber for Diagnostics

40   0   0.0 ( 0 )
 نشر من قبل Roger M. Jones
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

One of the still open issues for the development of superconducting insertion devices is the understanding of the beam heat load. With the aim of measuring the beam heat load to a cold bore and the hope to gain a deeper understanding in the beam heat load mechanisms, a cold vacuum chamber for diagnostics is under construction. The following diagnostics will be implemented: i) retarding field analyzers to measure the electron energy and flux, ii) temperature sensors to measure the total heat load, iii) pressure gauges, iv) and mass spectrometers to measure the gas content. The inner vacuum chamber will be removable in order to test different geometries and materials. This will allow the installation of the cryostat in different synchrotron light sources. COLDDIAG will be built to fit in a short straight section at ANKA. A first installation at the synchrotron light source Diamond is foreseen in June 2011. Here we describe the technical design report of this device and the planned measurements with beam.

قيم البحث

اقرأ أيضاً

This paper describes the development progress of high current superconducting RF linacs in Los Alamos, performed to support a design of the linac for the APT (Accelerator Production of Tritium) Project. The APT linac design includes a CW superconduct ing RF high energy section, spanning an energy range of 211 to 1030 MeV, and operating at a frequency of 700 MHz with two constant beta sections (beta of 0.64 and 0.82). In the last two years, we have progressed towards build a cryomodule with beta of 0.64. We completed the designs of the 5 cell superconducting cavities and the 210 kW power couplers. We are scheduled to begin assembly of the cryomodule in September 2000. In this paper, we present an overview of the status of our development efforts and a report on the results of the cavity and coupler test program.
A design study of the diagnostics of a high brightness linac, based on X-band structures, and a plasma accelerator stage, has been delivered in the framework of the EuPRAXIA@SPARC_LAB project. In this paper, we present a conceptual design of the prop osed diagnostics, using state of the art systems and new and under development devices. Single shot measurements are preferable for plasma accelerated beams, including emittance, while $mu$m level and fs scale beam size and bunch length respectively are requested. The needed to separate the driver pulse (both laser or beam) from the witness accelerated bunch imposes additional constrains for the diagnostics. We plan to use betatron radiation for the emittance measurement just at the end of the plasma booster, while other single-shot methods must be proven before to be implemented. Longitudinal measurements, being in any case not trivial for the fs level bunch length, seem to have already a wider range of possibilities.
CEA is committed to the design, construction and commissioning of a Medium Energy Beam Transfer line and a superconducting linac (SCL) for SARAF accelerator in order to accelerate 5mA beam of either protons from 1.3 MeV to 35 MeV or deuterons from 2. 6 MeV to 40 MeV. The Low Level RF (LLRF) is a subsystem of the CEA control domain for the SARAF-LINAC instrumentation. The top level requirement of the LLRF system has been presented in the last LLRF conference. The paper shows a simulink model to analyse and determinate the LLRF technical specification. The public bidding for SARAF LLRF is in the last phase: discussion with the selected company. The first prototype test will be performed at the start of 2020.
65 - M. Yadav , C. Hansel , Y. Zhuang 2021
The E-310 experiment at the Facility for Advanced Accelerator Experimental Tests II (FACET-II) at SLAC National Accelerator Laboratory aims to demonstrate the creation of high brightness beams from a plasma photocathode. Betatron radiation will be me asured by a Compton spectrometer, currently under development at UCLA, to provide single-shot, nondestructive beam diagnostics. We give a brief overview of this spectrometer as well as double differential spectrum reconstruction from the spectrometer image and beam parameter reconstruction from this double differential spectrum. We discuss three models for betatron radiation: an idealized particle tracking code which computes radiation from Lienard-Wiechert potentials, a quasi-static particle-in-cell (PIC) code which computes radiation from Lienard-Wiechert potentials, and a full PIC code which computes radiation using a Monte Carlo QED method. Spectra computed by the three models for a simple case are compared.
The Time-of-Flight (ToF) technique coupled with semiconductor-like detectors, as silicon carbide and diamond, is one of the most promising diagnostic methods for high-energy, high repetition rate, laser-accelerated ions allowing a full on-line beam s pectral characterization. A new analysis method for reconstructing the energy spectrum of high-energy laser-driven ion beams from TOF signals is hereby presented and discussed. The proposed method takes into account the detectors working principle, through the accurate calculation of the energy loss in the detector active layer, using Monte Carlo simulations. The analysis method was validated against well-established diagnostics, such as the Thomson Parabola Spectrometer, during an experimental campaign carried out at the Rutherford Appleton Laboratory (RAL, UK) with the high-energy laser-driven protons accelerated by the VULCAN Petawatt laser.