ترغب بنشر مسار تعليمي؟ اضغط هنا

Study of a Large NaI(Tl) Crystal

354   0   0.0 ( 0 )
 نشر من قبل Luca Doria
 تاريخ النشر 2010
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Using a narrow band positron beam, the response of a large high-resolution NaI(Tl) crystal to an incident positron beam was measured. It was found that nuclear interactions cause the appearance of additional peaks in the low energy tail of the deposited energy spectrum.

قيم البحث

اقرأ أيضاً

72 - H.W.Joo , H.S.Park , J.H.Kim 2018
Scintillation crystals are commonly used for direct detection of weakly interacting massive particles (WIMPs), which are suitable candidates for a particle dark matter. It is well known that the scintillation light yields are different for electron r ecoil and nuclear recoil. To calibrate the energies of WIMP-induced nuclear recoil signals, the quenching factor (QF) needs to be measured, which is the light yield ratio of the nuclear recoil to electron recoil. Measurements of the QFs for Na and I recoils in a small (2 cm x 2 cm x 1.5 cm) NaI(Tl) crystal are performed with 2.43-MeV mono-energetic neutrons generated by deuteron-deuteron fusion. Depending on the scattering angle of the neutrons, the energies of the recoiled ions vary in the range of 9 - 152 keV for Na and 19 - 75 keV for I. The QFs of Na are measured at 9 points with values in the range of 10 - 23 % while those of I are measured at 4 points with values in the range of 4 - 6 %.
72 - J.J. Choi , B.J. Park , C. Ha 2020
NaI(Tl) crystals are used as particle detectors in a variety of rare-event search experiments because of their superb light-emission quality. The crystal light yield is generally high, above 10 photoelectrons per keV, and its emission spectrum is pea ked around 400 nm, which matches well to the sensitive region of bialkali photocathode photomultiplier tubes. However, since NaI(Tl) crystals are hygroscopic, a sophisticated method of encapsulation has to be applied that prevents moisture from chemically attacking the crystal and thereby degrading the emission. In addition, operation with low energy thresholds, which is essential for a number of new phenomenon searches, is usually limited by the crystal light yield; in these cases higher light yields can translate into lower thresholds that improve the experimental sensitivity. Here we describe the development of an encapsulation technique that simplifies the overall design by attaching the photo sensors directly to the crystal so that light losses are minimized. The light yield of a NaI(Tl) crystal encapsulated with this technique was improved by more than 30%, and as many as 22 photoelectrons per keV have been measured. Consequently, the energy threshold can be lowered and the energy resolution improved. Detectors with this higher light yield are sensitive to events with sub-keV energies and well suited for low-mass dark matter particle searches and measurements of neutrino-nucleus coherent scattering.
We present new results on the radiopurity of a 3.4-kg NaI(Tl) crystal scintillator operated in the SABRE proof-of-principle detector setup. The amount of potassium contamination, determined by the direct counting of radioactive $^{40}$K, is found to be $2.2pm1.5$ ppb, lowest ever achieved for NaI(Tl) crystals. With the active veto, the average background rate in the crystal in the 1-6 keV energy region-of-interest (ROI) is $1.20pm0.05$ counts/day/kg/keV, which is a breakthrough since the DAMA/LIBRA experiment. Our background model indicates that the rate is dominated by $^{210}$Pb and that about half of this contamination is located in the PTFE reflector. We discuss ongoing developments of the crystal manufacture aimed at the further reduction of the background, including data from purification by zone refining. A projected background rate lower than $sim$0.2 counts/day/kg/keV in the ROI is within reach. These results represent a benchmark for the development of next-generation NaI(Tl) detector arrays for the direct detection of dark matter particles.
The scintillation light output of a pure and a Thallium doped Sodium Iodide (NaI) crystal under irradiation with 5.486MeV alpha -particles has been measured over a temperature range from 1.7K to 300K. Estimates of the decay time constant at three sel ected temperatures are given. For pure NaI an increase in light yield towards low temperatures could be confirmed and measured at higher precision. For NaI(Tl) below 60K an increase in light output has been found.
We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball detector obtained from a study of single p0 photoproduction on deuterium using the tagged photon beam at the Mainz Microtron. The results were obtained up to a neutron energy of 400 MeV. They are compared to previous measurements made more than 15 years ago at the pion beam at the BNL AGS.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا