We discuss the results of a multi-wavelength differential imaging lab experiment with the High Contrast Imaging Testbed (HCIT) at the Jet Propulsion Laboratory. The HCIT combines a Lyot coronagraph with a Xinetics deformable mirror in a vacuum environment to simulate a space telescope in order to test technologies and algorithms for a future exoplanet coronagraph mission. At present, ground based telescopes have achieved significant attenuation of speckle noise using the technique of spectral differential imaging (SDI). We test whether ground-based SDI can be generalized to a non-simultaneous spectral differential imaging technique (NSDI) for a space mission. In our lab experiment, a series of 5 filter images centered around the O2(A) absorption feature at 0.762 um were acquired at nominal contrast values of 10^-6, 10^-7, 10^-8, and 10^-9. Outside the dark hole, single differences of images improve contrast by a factor of ~6. Inside the dark hole, we found significant speckle chromatism as a function of wavelength offset from the nulling wavelength, leading to a contrast degradation by a factor of 7.2 across the entire ~80 nm bandwidth. This effect likely stems from the chromatic behavior of the current occulter. New, less chromatic occulters are currently in development; we expect that these new occulters will resolve the speckle chromatism issue.

قيم البحث

اقرأ أيضاً

Future high-contrast imagers on ground-based extremely large telescopes will have to deal with the segmentation of the primary mirrors. Residual phase errors coming from the phase steps at the edges of the segments will have to be minimized in order to reach the highest possible wavefront correction and thus the best contrast performance. To study these effects, we have developed the MITHIC high-contrast testbed, which is designed to test various strategies for wavefront sensing, including the Zernike sensor for Extremely accurate measurements of Low-level Differential Aberrations (ZELDA) and COronagraphic Focal-plane wave-Front Estimation for Exoplanet detection (COFFEE). We recently equipped the bench with a new atmospheric turbulence simulation module that offers both static phase patterns representing segmented primary mirrors and continuous phase strips representing atmospheric turbulence filtered by an AO or an XAO system. We present a characterisation of the module using different instruments and wavefront sensors, and the first coronagraphic measurements obtained on MITHIC.
In Spring 2013, the LEECH (LBTI Exozodi Exoplanet Common Hunt) survey began its $sim$130-night campaign from the Large Binocular Telescope (LBT) atop Mt Graham, Arizona. This survey benefits from the many technological achievements of the LBT, includ ing two 8.4-meter mirrors on a single fixed mount, dual adaptive secondary mirrors for high Strehl performance, and a cold beam combiner to dramatically reduce the telescopes overall background emissivity. LEECH neatly complements other high-contrast planet imaging efforts by observing stars at L (3.8 $mu$m), as opposed to the shorter wavelength near-infrared bands (1-2.4 $mu$m) of other surveys. This portion of the spectrum offers deep mass sensitivity, especially around nearby adolescent ($sim$0.1-1 Gyr) stars. LEECHs contrast is competitive with other extreme adaptive optics systems, while providing an alternative survey strategy. Additionally, LEECH is characterizing known exoplanetary systems with observations from 3-5$mu$m in preparation for JWST.
The objective of the SPHERE Data Center is to optimize the scientific return of SPHERE at the VLT, by providing optimized reduction procedures, services to users and publicly available reduced data. This paper describes our motivation, the implementa tion of the service (partners, infrastructure and developments), services, description of the on-line data, and future developments. The SPHERE Data Center is operational and has already provided reduced data with a good reactivity to many observers. The first public reduced data have been made available in 2017. The SPHERE Data Center is gathering a strong expertise on SPHERE data and is in a very good position to propose new reduced data in the future, as well as improved reduction procedures.
Specific high contrast imaging instruments are mandatory to characterize circumstellar disks and exoplanets around nearby stars. Coronagraphs are commonly used in these facilities to reject the diffracted light of an observed star and enable the dire ct imaging and spectroscopy of its circumstellar environment. One important property of the coronagraph is to be able to work in broadband light. Among several proposed coronagraphs, the dual-zone phase mask coronagraph is a promising solution for starlight rejection in broadband light. In this paper, we perform the first validation of this concept in laboratory. First, we recall the principle of the dual-zone phase mask coronagraph. Then, we describe the high-contrast imaging THD testbed, the manufacturing of the components and the quality-control procedures. Finally, we study the sensitivity of our coronagraph to low-order aberrations (inner working angle and defocus) and estimate its contrast performance. Our experimental broadband light results are compared with numerical simulations to check agreement with the performance predictions. With the manufactured prototype and using a dark hole technique based on the self-coherent camera, we obtain contrast levels down to $2,10^{-8}$ between 5 and 17$,lambda_0/D$ in monochromatic light (640 nm). We also reach contrast levels of $4,10^{-8}$ between 7 and 17$lambda_0/D$ in broadband ($lambda_0=675$ nm, $Deltalambda=250$ nm and $Deltalambda / lambda_0 = 40$ %), which demonstrates the excellent chromatic performance of the dual-zone phase mask coronagraph. The performance reached by the dual-zone phase mask coronagraph is promising for future high-contrast imaging instruments that aim at detecting and spectrally characterizing old or light gaseous planets.
As planning for the next generation of high contrast imaging instruments (e.g. WFIRST, HabEx, and LUVOIR, TMT-PFI, EELT-EPICS) matures, and second-generation ground-based extreme adaptive optics facilities (e.g. VLT-SPHERE, Gemini-GPI) are halfway th rough their principal surveys, it is imperative that the performance of different designs, post-processing algorithms, observing strategies, and survey results be compared in a consistent, statistically robust framework. In this paper, we argue that the current industry standard for such comparisons -- the contrast curve -- falls short of this mandate. We propose a new figure of merit, the performance map, that incorporates three fundamental concepts in signal detection theory: the true positive fraction (TPF), false positive fraction (FPF), and detection threshold. By supplying a theoretical basis and recipe for generating the performance map, we hope to encourage the widespread adoption of this new metric across subfields in exoplanet imaging.