The performance of IHEP-NDL LGAD sensors after neutron irradiation

281   0   0.0 ( 0 )
 Added by Yunyun Fan
 Publication date 2021
  fields Physics
and research's language is English




Ask ChatGPT about the research

The performances of Low Gain Avalanche diode (LGAD) sensors from a neutron irradiation campaign with fluences of 0.8 x 10^15, 15 x 10^15 and 2.5 x 10^15 neq/cm2 are reported in this article. These LGAD sensors are developed by the Institute of High Energy Physics, Chinese Academy of Sciences and the Novel Device Laboratory for the High Granularity Timing Detector of the High Luminosity Large Hadron Collider. The timing resolution and collected charge of the LGAD sensors were measured with electrons from a beta source. After irradiation with a fluence of 2.5 x 10^15 neq/cm2, the collected charge decreases from 40 fC to 7 fC, the signal-to-noise ratio deteriorates from 48 to 12, and the timing resolution increases from 29 ps to 39 ps.



rate research

Read More

146 - Yuhang Tan , Tao Yang , Suyu Xiao 2020
We study the radiation effects of the Low Gain Avalanche Detector (LGAD) sensors developed by the Institute of High Energy Physics (IHEP) and the Novel Device Laboratory (NDL) of Beijing Normal University in China. These new sensors have been irradiated at the China Institute of Atomic Energy (CIAE) using 100 MeV proton beam with five different fluences from 7$times10^{14}$ $n_{eq}/cm^2$ up to 4.5$times10^{15}$ $n_{eq}/cm^2$. The result shows the effective doping concentration in the gain layer decreases with the increase of irradiation fluence, as expected by the acceptor removal mechanism. By comparing data and model gives the acceptor removal coefficient $c_{A}$ = $(6.07pm0.70)times10^{-16}~cm^2$, which indicates the NDL sensor has fairly good radiation resistance.
The timing measurement of charged particles using silicon detector is widely used in synchrotron source as X-ray detectors, in time-of-flight mass spectrometer and especially in large collider experiment. To reduce the drastically event pile-up of high-luminosity large hadron collider (HL-LHC), a new concept of 4-dimension detector including timing and positon has been proposed. One of the candidates for the 4-dimension detector is a new kind of silicon detector called Low Gain Avalanche Diode (LGAD). In China, Institute of High Energy Physics (IHEP) Chinese Academic Science cooperated with Novel Device Laboratory (NDL) at Beijing Normal University have fabricated a series of LGAD sensors. The characterization of the first prototype of IHEP-NDL sensors is presented including leakage current and sensor capacitance measurement. A test system for the time resolution of jitter term using pico-second laser and fast sampling rate oscilloscope is also setup, and the time resolution of 10 ps can be achieved with these sensors.
To meet the timing resolution requirement of up-coming High Luminosity LHC (HL-LHC), a new detector based on the Low-Gain Avalanche Detector(LGAD), High-Granularity Timing Detector (HGTD), is under intensive research in ATLAS. Two types of IHEP-NDL LGADs(BV60 and BV170) for this update is being developed by Institute of High Energy Physics (IHEP) of Chinese Academic of Sciences (CAS) cooperated with Novel Device Laboratory (NDL) of Beijing Normal University and they are now under detailed study. These detectors are tested with $5GeV$ electron beam at DESY. A SiPM detector is chosen as a reference detector to get the timing resolution of LGADs. The fluctuation of time difference between LGAD and SiPM is extracted by fitting with a Gaussian function. Constant fraction discriminator (CFD) method is used to mitigate the effect of time walk. The timing resolution of $41 pm 1 ps$ and $63 pm 1 ps$ are obtained for BV60 and BV170 respectively.
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|eta|<4.0$ with two end caps on each side and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the vario
221 - C. Agapopoulou , S. Blin , A. Blot 2020
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the performance of the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2$times$2 LGAD array of 1.1$times$1.1 mm$^2$ pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect that arises from the different response of the preamplifier for various injected charges can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.