Do you want to publish a course? Click here

XUV frequency comb operation in an astigmatism-compensated enhancement cavity

288   0   0.0 ( 0 )
 Added by Janko Nauta
 Publication date 2020
  fields Physics
and research's language is English




Ask ChatGPT about the research

We have developed an extreme ultraviolet (XUV) frequency comb for performing ultra-high precision spectroscopy on the many XUV transitions found in highly charged ions (HCI). Femtosecond pulses from a 100 MHz phase-stabilized near-infrared frequency comb are amplified and then fed into a femtosecond enhancement cavity (fsEC) inside an ultra-high vacuum chamber. The low-dispersion fsEC coherently superposes several hundred incident pulses and, with a single cylindrical optical element, fully compensates astigmatism at the $w_0=15mu$m waist cavity focus. With a gas jet installed there, intensities reaching $sim10^{14}$ W/cm$^2$ generate coherent high harmonics with a comb spectrum at 100 MHz rate. We couple out of the fsEC harmonics from the 7th up to the 35th (42 eV; 30 nm) to be used in upcoming experiments on HCI frequency metrology.



rate research

Read More

125 - Bruno Chanteau 2012
We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an ultrastable 1.55 $mu$m frequency reference signal, transferred from LNE-SYRTE to LPL through an optical link. We are now progressing towards the stabilization of the mid-IR laser via the frequency comb and the extension of this technique to quantum cascade lasers. Such a development is very challenging for ultrahigh resolution molecular spectroscopy and fundamental tests of physics with molecules.
Direct frequency comb spectroscopy of trapped ions is demonstated for the first time. It is shown that the 4s^2S_(1/2)-4p^2P_(3/2) transition in calcium ions can be excited directly with a frequency comb laser that is upconverted to 393 nm. Detection of the transition is performed using a shelving scheme to suppress background signal from non-resonant comb modes. The measured transition frequency of f=761 905 012.7(0.5) MHz presents an improvement in accuracy of more than two orders of magnitude.
We propose and demonstrate a scheme to enable Doppler compensation within optical cavities for atom interferometry at significantly increased mode diameters. This has the potential to overcome the primary limitations in cavity enhancement for atom interferometry, circumventing the cavity linewidth limit and enabling mode filtering, power enhancement, and a large beam diameter simultaneously. This approach combines a magnified linear cavity with an intracavity Pockels cell. The Pockels cell introduces a voltage tunable birefringence allowing the cavity mode frequencies to track the Raman lasers as they scan to compensate for gravitationally induced Doppler shifts, removing the dominant limitation of current cavity enhanced systems. A cavity is built to this geometry and shown to simultaneously realize the capability required for Doppler compensation, with a 5.04~mm $1/e^{2}$ diameter beam waist and an enhancement factor of $>$5x at a finesse of 35. Furthermore, this has a tunable Gouy phase, allowing the suppression of higher order spatial modes and the avoidance of regions of instability. This approach can therefore enable enhanced contrast and longer atom interferometry times while also enabling the key features of cavity enhanced atom interferometry, power enhancement and the reduction of aberrations. This is relevant to future reductions in the optical power requirement of quantum technology, or in providing enhanced performance for atom interferometers targeting fundamental science.
We demonstrate a femtosecond enhancement cavity with a crossed-beam geometry for efficient generation and extraction of extreme-ultraviolet (XUV) frequency combs at a 154 MHz repetition rate. We achieve a record-high out-coupled power of 600 {mu}W, directly usable for spectroscopy, at a wavelength of 97 nm. This corresponds to a >60% out-coupling efficiency. The XUV power scaling and generation efficiency are similar to that achieved with a single Gaussian-mode fundamental beam inside a collinear enhancement cavity. The noncollinear geometry also opens the door for the generation of isolated attosecond pulses at >100 MHz repetition rate.
We describe a coherent mid-infrared continuum source with 700 cm-1 usable bandwidth, readily tuned within 600 - 2500 cm-1 (4 - 17 mum) and thus covering much of the infrared fingerprint molecular vibration region. It is based on nonlinear frequency conversion in GaSe using a compact commercial 100-fs-pulsed Er fiber laser system providing two amplified near-infrared beams, one of them broadened by a nonlinear optical fiber. The resulting collimated mid-infrared continuum beam of 1 mW quasi-cw power represents a coherent infrared frequency comb with zero carrier-envelope phase, containing about 500,000 modes that are exact multiples of the pulse repetition rate of 40 MHz. The beams diffraction-limited performance enables long-distance spectroscopic probing as well as maximal focusability for classical and ultraresolving near-field microscopies. Applications are foreseen also in studies of transient chemical phenomena even at ultrafast pump-probe scale, and in high-resolution gas spectroscopy for e.g. breath analysis.
comments
Fetching comments Fetching comments
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا