This experiment demonstrates to engineering students that control system and power system theory are not orthogonal, but highly interrelated. It introduces a real-world power system problem to enhance time domain State Space Modelling (SSM) skills of students. It also shows how power quality is affected with real-world scenarios. Power system was modeled in State Space by following its circuit topology in a bottom-up fashion. At two different time instances of the power generator sinusoidal wave, the transmission line was switched on. Fourier transform was used to analyze resulting line currents. It validated the harmonic components, as expected, from power system theory. Students understood the effects of switching transients at various times on supply voltage sinusoid within control theory and learned time domain analysis. They were surveyed to gauge their perception of the project. Results from a before/after assessment analyzed using T-Tests showed a statistically significant enhanced learning in SSM.
Increasing penetration of renewable energy introduces significant uncertainty into power systems. Traditional simulation-based verification methods may not be applicable due to the unknown-but-bounded feature of the uncertainty sets. Emerging set-theoretic methods have been intensively investigated to tackle this challenge. The paper comprehensively reviews these methods categorized by underlying mathematical principles, that is, set operation-based methods and passivity-based methods. Set operation-based methods are more computationally efficient, while passivity-based methods provide semi-analytical expression of reachable sets, which can be readily employed for control. Other features between different methods are also discussed and illustrated by numerical examples. A benchmark example is presented and solved by different methods to verify consistency.
We employ a novel data-enabled predictive control (DeePC) algorithm in voltage source converter (VSC) based high-voltage DC (HVDC) stations to perform safe and optimal wide-area control for power system oscillation damping. Conventional optimal wide-area control is model-based. However, in practice detailed and accurate parametric power system models are rarely available. In contrast, the DeePC algorithm uses only input/output data measured from the unknown system to predict the future trajectories and calculate the optimal control policy. We showcase that the DeePC algorithm can effectively attenuate inter-area oscillations even in the presence of measurement noise, communication delays, nonlinear loads and uncertain load fluctuations. We investigate the performance under different matrix structures as data-driven predictors. Furthermore, we derive a novel Min-Max DeePC algorithm to be applied independently in multiple VSC-HVDC stations to mitigate inter-area oscillations, which enables decentralized and robust optimal wide-area control. Further, we discuss how to relieve the computational burden of the Min-Max DeePC by reducing the dimension of prediction uncertainty and how to leverage disturbance feedback to reduce the conservativeness of robustification. We illustrate our results with high-fidelity, nonlinear, and noisy simulations of a four-area test system.
The need for Enhanced Frequency Response (EFR) is expected to increase significantly in future low-carbon Great Britain (GB) power system. One way to provide EFR is to use power electronic compensators (PECs) for point-of-load voltage control (PVC) to exploit the voltage dependence of loads. This paper investigates the techno-economic feasibility of such technology in future GB power system by quantifying the total EFR obtainable through deploying PVC in the urban domestic sector, the investment cost of the installment and the economic and environmental benefits of using PVC. The quantification is based on a stochastic domestic demand model and generic medium and low-voltage distribution networks for the urban areas of GB and a stochastic unit commitment (SUC) model with constraints for secure post-fault frequency evolution is used for the value assessment. Two future energy scenarios in the backdrop of 2030 with `smart and `non-smart control of electric vehicles and heat pumps, under different levels of penetration of battery energy storage system (BESS) are considered to assess the value of PEC, as well as the associated payback period. It is demonstrated that PVC could effectively complement BESS towards EFR provision in future GB power system.
Data-driven control that circumvents the process of system identification by providing optimal control inputs directly from system data has attracted renewed attention in recent years. In this paper, we focus on understanding the effects of the regularization on the data-enabled predictive control (DeePC) algorithm. We provide theoretical motivation and interpretation for including a quadratic regularization term. Our analysis shows that the quadratic regularization term leads to robust and optimal solutions with regards to disturbances affecting the data. Moreover, when the input/output constraints are inactive, the quadratic regularization leads to a closed-form solution of the DeePC algorithm and thus enables fast calculations. On this basis, we propose a framework for data-driven synchronization and power regulations of power converters, which is tested by high-fidelity simulations and experiments.
We present an omnidirectional wireless power transfer (WPT) system capable of automatic power flow control using three orthogonal transmitter (Tx)-repeater (Rp) pairs. The power drawn from each transmitter is automatically adjusted depending on the mutual inductance between the receiver and the Tx-Rp pair. The proposed approach enables the receiver to harvest almost uniform power with high efficiency (90%) regardless of its position.