No Arabic abstract
We report on the development of a front-end ASIC for silicon-strip detectors of the J-PARC Muon g-2/EDM experiment. This experiment aims to measure the muon anomalous magnetic moment and electric dipole moment precisely to explore new physics beyond the Standard Model. Since the time and momentum of positrons from muon decay are key information in the experiment, a fast response with high granularity is demanded to silicon-strip detectors as the positron tracker. The readout ASIC is thus required to tolerate a high hit rate of 1.4 MHz per strip and to have deep memory for the period of 40 us with 5 ns time resolution. To satisfy the experimental requirements, an analog prototype ASIC was newly designed with the Silterra 180 nm CMOS technology. In the evaluation test, the time-walk was demonstrated to reach 0.8~ns with a sufficient dynamic range of 6~MIPs and pulse width of 45~ns for 1 MIP event. The design details and performance of the ASIC are discussed in this article.
A new silicon-strip readout chip named SliT has been developed for the measurement of the muon anomalous magnetic moment and electric dipole moment at J-PARC. The SliT is designed in the Silterra 180 nm CMOS technology with mixed-signal integrated circuits. An analog circuit incorporates a conventional charge-sensitive amplifier, shaping amplifiers, and two distinct discriminators for each of 128 identical channels. A digital part includes storage memories, an event building block, a serializer, and LVDS drivers. A distinct feature of the SliT is utilization of the zero-cross architecture, which consists of a CR-RC filter followed by a CR circuit as a voltage differentiator. This architecture enables to generate hit signals with subnanosecond amplitude-independent time walk, which is the primary requirement for the experiment. The test results show the time walk of $0.38 pm 0.16$ ns between 0.5 and 3 MIP signals. The equivalent noise charge is $1547 pm 75 $ $e^{-}$ (rms) at $C_{rm det} = 33$ pF as a strip-sensor capacitance. Other functionalities such as a strip-sensor readout chip have also been proven in the tests. The SliT128C satisfies all requirements of the J-PARC muon $g-2$/EDM experiment.
For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must maintain the performance of the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2$times$2 LGAD array of 1.1$times$1.1 mm$^2$ pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect that arises from the different response of the preamplifier for various injected charges can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.
A new experiment at Fermilab will measure the anomalous magnetic moment of the muon with a precision of 140 parts per billion (ppb). This measurement is motivated by the results of the Brookhaven E821 experiment that were first released more than a decade ago, which reached a precision of 540 ppb. As the corresponding Standard Model predictions have been refined, the experimental and theoretical values have persistently differed by about 3 standard deviations. If the Brookhaven result is confirmed at Fermilab with this improved precision, it will constitute definitive evidence for physics beyond the Standard Model. The experiment observes the muon spin precession frequency in flight in a well-calibrated magnetic field; the improvement in precision will require both 20 times as many recorded muon decay events as in E821 and a reduction by a factor of 3 in the systematic uncertainties. This paper describes the current experimental status as well as the plans for the upgraded magnet, detector and storage ring systems that are being prepared for the start of beam data collection in 2017.
We present our latest ASIC, which is used for the readout of Cadmium Telluride double-sided strip detectors (CdTe DSDs) and high spectroscopic imaging. It is implemented in a 0.35 um CMOS technology (X-Fab XH035), consists of 64 readout channels, and has a function that performs simultaneous AD conversion for each channel. The equivalent noise charge of 54.9 e- +/- 11.3 e- (rms) is measured without connecting the ASIC to any detectors. From the spectroscopy measurements using a CdTe single-sided strip detector, the energy resolution of 1.12 keV (FWHM) is obtained at 13.9 keV, and photons within the energy from 6.4 keV to 122.1 keV are detected. Based on the experimental results, we propose a new low-noise readout architecture making use of a slew-rate limited mode at the shaper followed by a peak detector circuit.
There is a long standing discrepancy between the Standard Model prediction for the muon g-2 and the value measured by the Brookhaven E821 Experiment. At present the discrepancy stands at about three standard deviations, with a comparable accuracy between experiment and theory. Two new proposals -- at Fermilab and J-PARC -- plan to improve the experimental uncertainty by a factor of 4, and it is expected that there will be a significant reduction in the uncertainty of the Standard Model prediction. I will review the status of the planned experiment at Fermilab, E989, which will analyse 21 times more muons than the BNL experiment and discuss how the systematic uncertainty will be reduced by a factor of 3 such that a precision of 0.14 ppm can be achieved.