Do you want to publish a course? Click here

Development of Single- and Double-sided Ladders for the ILD Vertex Detectors

180   0   0.0 ( 0 )
 Added by Jerome Baudot
 Publication date 2012
  fields Physics
and research's language is English




Ask ChatGPT about the research

We discuss two projects exploring the integration of thin CMOS pixel sensors in order to prototype ladders matching the geometry needed for the ILD vertex detector. The PLUME project has designed and fabricated full-size and fully functional double- sided layers which currently reach 0.6 % X0 and aim for 0.3 % X0 in mid-2012. Another approach, SERNWIETE, consists in wrapping the sensors in a polyimide-based micro-cable to obtain a supportless single-sided ladder with a material budget around 0.15 % X0. First promising samples have been produced and the full-size prototype is expected in spring 2012.



rate research

Read More

CMOS Pixel Sensors are making steady progress towards the specifications of the ILD vertex detector. Recent developments are summarised, which show that these devices are close to comply with all major requirements, in particular the read-out speed needed to cope with the beam related background. This achievement is grounded on the double- sided ladder concept, which allows combining signals generated by a single particle in two different sensors, one devoted to spatial resolution and the other to time stamp, both assembled on the same mechanical support. The status of the development is overviewed as well as the plans to finalise it using an advanced CMOS process.
168 - N. Chon-Sen , J. Baudot , G. Claus 2010
The development of ultra-light pixelated ladders is motivated by the requirements of the ILD vertex detector at ILC. This paper summarizes three projects related to system integration. The PLUME project tackles the issue of assembling double-sided ladders. The SERWIETE project deals with a more innovative concept and consists in making single-sided unsupported ladders embedded in an extra thin plastic enveloppe. AIDA, the last project, aims at building a framework reproducing the experimental running conditions where sets of ladders could be tested.
197 - Arantza Oyanguren 2012
The vertex detectors are crucial detectors for future linear e+e- colliders since they must give the most accurate location of any outgoing charged particles originating from the interaction point. The DEPFET collaboration is developing a new type of pixel sensors which provide very low noise and high spatial resolution. In order to precisely determine the track and vertex positions, multiple scattering in the detector has to be reduced by minimizing the material in the sensors, cooling, and support structures. A new method of cooling by blowing air over the sensors has been developed and tested. It is applied in the design and construction of the Belle-II detector and may be used in the new generation of vertex detectors for linear colliders.
187 - Rita De Masi , Marc Winter 2009
The impact of the incoherent electron-positron pairs from beamstrahlung on the occupancy of the vertex detector (VXD) for the International Large Detector concept (ILD) has been studied, based on the standard ILD simulation tools. The occupancy was evaluated for two substantially different sensor technology in order to estimate the importance of the latter. The influence of an anti-DID field removing backscattered electrons has also been studied.
112 - Y. P. Zhang , J. C. Liu , C. Guo 2017
The radioactive noble gas $^{222}$Rn, which can be dissolved in water, is an important background source for JUNO. In this paper, based on the water system of JUNO prototype, two kinds of high sensitivity radon detectors have been proposed and developed. The sensitivity of Si-PIN Rn detector, which uses a Si-PIN photodiode to detect the $alpha$ from $^{214}$Po decay, is $sim$9.0~mBq/m$^3$. The sensitivity of LS Rn detector, which uses liquid scintillator to detect the coincident signals of $beta$ from $^{214}$Bi decay and $alpha$ from $^{214}$Po decay, is $sim$64.0~mBq/m$^3$. Both of the two kinds of Rn detector have the potential to be developed as an online Rn concentration monitoring equipment for JUNO veto detector.
comments
Fetching comments Fetching comments
Sign in to be able to follow your search criteria
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا