Fixed bed adsorption columns packed with natural zeolite were used to study the
kinetics of heavy metals removal from the single component solutions of Vanadium, Nikle,
Zinc, and Lead. The system parameters studied include solution flow rate and be
d height.
The effect of competing cations was also studied to establish the effectiveness of natural
zeolite in treating Industrial wastewater under continuous conditions using fixed bed
columns. The metal loaded natural zeolite was regenerated using NaCl . The results from
column studies showed that the Slower flow rates gave better removal efficiencies
compared to faster ones, Longer bed heights also resulted in greater adsorption
efficiencies. The bed depth service time (BDST) model was successfully used to simulate
experimental results at 30 % breakthrough. This model provides the necessary parameters
needed for fixed bed column design, the factor R2 ranged between 0.91 – 0.95. Natural
zeolite was exposed to 3 cycles of adsorption and desorption. The efficiency of the column
in removing heavy metals was high, The results indicate that natural zeolite can be
regenerated and re-used in removing heavy metals from solution.