Do you want to publish a course? Click here

Modern and future optical networks rely on wavelength divisional multiplexing technology, it was necessary to developed the whole network elements to keep up with the increasing need to offer a wide band and a very short time delay and high reliabi lity, and replacement of electro optic equipment with optical equipment. Optical amplifiers have taken an important part in this evolution, and the Raman amplifier (RAMAN) had a great deal of attention, for its high gain and flattened gain. In this paper, we have examined the effect of both fiber parameters and pump parameters on the performance of Raman optical amplifier in terms of gain and bandwidth and the used pump power. This research demonstrated the effect of multi pump on this amplifier performance and its flattening and bandwidth, and we reached a flattening gain on a wide bandwidth. The simulation was done by using MATLAB and OPTISYSTEM program based on the mathematical equations that describe the amplifier model for 1450nm-1650nm bandwidth.
The research study scenarios water hammer problem that may cause the destruction of the irrigation pipes, pumping stations and equipmen and part of the irrigation project in terms Ain Beida and its environs in the north-eastern city of Latakia, whe re the project seeks to quench 5,000 hectares of land with water pumped from Lake Dam November 16 occurrence . It consists of four pumping stations in addition to major irrigation systems and irrigation systems subsidiary. Used in these stations pipes made of steel (Steel) , The reservoir project's main reservoir is two. Bently and Water CAD V8 XM Edition we have in this research with the help of the CD-networking program Modeling of these stations to save time and effort in the study, are HAMMER V8 XM Edition Determine Adhamiya pressures and velocities in the case of runoff stable, identifying pressures Adhamiya in the case of the flow is stable through the development scenario of a water hammer caused by the sudden closure of the valve irreversibility thus leading larger than the carrying capacity of pipes and fittings have a high pressure values, and put another scenario shows the effect of non-use non-return valve in the water hammer occurs, and its role as a good protection of them Thus leading to high pressures and dangerous far greater than the carrying capacity of the pipe fittings values, and also used the compressed air reservoir in the third scenario means other protection from water hammer, and we found through Adhamiya pressures resulting values that the compressed air tank means better protection; it has to prevent any increase in pressure values Adhamiya when water hammer occurs, and kept her on the values that were in the case of steady flow.
The research includes an analytical study of long term pumping test with observation wells to get the optimum determination of the most important hydrogeological parameters of confined aquifer in Banyas, by pumping from a well with average pumping rate 10104m3/day for 36 hours and only 5 hours of complete recovery groundwater level. This test is accompanied by measuring the variations of the groundwater levels in the monitoring wells. Analytical methods of steady- unsteady of groundwater flow are used to evaluate the long term pumping test, and then to determine the optimum evaluation. The Transmissivity of the confined aquifer is about 5000 m2/day (very high potential), and the storage coefficient is 1,8.10-4. Then they used to predict the groundwater drawdown during one day. So, we can get 20000 m3/day from the aquifer and the drawdown not more than 1,75 m as quasi-steady drawdown at distance 500 m from the pumping well.
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا