ترغب بنشر مسار تعليمي؟ اضغط هنا

Coherent X-ray Diffractive Imaging; applications and limitations

187   0   0.0 ( 0 )
 نشر من قبل Stefano Marchesini
 تاريخ النشر 2003
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The inversion of a diffraction pattern offers aberration-free diffraction-limited 3D images without the resolution and depth-of-field limitations of lens-based tomographic systems, the only limitation being radiation damage. We review our experimental results, discuss the fundamental limits of this technique and future plans.



قيم البحث

اقرأ أيضاً

Attosecond science has been transforming our understanding of electron dynamics in atoms, molecules and solids. However, to date almost all of the attoscience experiments have been based on spectroscopic measurements because attosecond pulses have in trinsically very broad spectra due to the uncertainty principle and are incompatible with conventional imaging systems. Here we report an important advance towards achieving attosecond coherent diffractive imaging. Using simulated attosecond pulses, we simultaneously reconstruct the spectrum, 17 probes and 17 spectral images of extended objects from a set of ptychographic diffraction patterns. We further confirm the principle and feasibility of this method by successfully performing a ptychographic coherent diffractive imaging experiment using a light-emitting diode with a broad spectrum. We believe this work clear the way to an unexplored domain of attosecond imaging science, which could have a far-reaching impact across different disciplines.
We present the experimental reconstruction of sub-wavelength features from the far-field intensity of sparse optical objects: sparsity-based sub-wavelength imaging combined with phase-retrieval. As examples, we demonstrate the recovery of random and ordered arrangements of 100 nm features with the resolution of 30 nm, with an illuminating wavelength of 532 nm. Our algorithmic technique relies on minimizing the number of degrees of freedom; it works in real-time, requires no scanning, and can be implemented in all existing microscopes - optical and non-optical.
The Fourier inversion of phased coherent diffraction patterns offers images without the resolution and depth-of-focus limitations of lens-based tomographic systems. We report on our recent experimental images inverted using recent developments in pha se retrieval algorithms, and summarize efforts that led to these accomplishments. These include ab-initio reconstruction of a two-dimensional test pattern, infinite depth of focus image of a thick object, and its high-resolution (~10 nm resolution) three-dimensional image. Developments on the structural imaging of low density aerogel samples are discussed.
By using phase retrieval, Bragg Coherent Diffractive Imaging (BCDI) allows tracking of three-dimensional displacement fields inside individual nanocrystals. Nevertheless, in the presence of significant (1% and higher) strains, such as in the process of a structural phase transformation, fails due to the Bragg peak distortions. Here we present an advanced BCDI algorithm enabling imaging three-dimensional strain fields in highly strained crystals. We test the algorithm on particles simulated to undergo a structural phase transformation. While the conventional algorithm fails in unambiguously reconstructing the phase morphology, our algorithm correctly retrieves the morphology of coexistent phases with a strain difference of 1%. The key novelty is the simultaneous reconstruction of multiple scans of the same nanoparticle at snapshots through the phase transformations. The algorithm enables visualizing phase transformations in nanoparticles of lithium-ion, sodium-ion nanoparticles, and other nanoparticulate materials in working conditions (operando).
Coherent diffractive imaging (CDI) has been widely applied in the physical and biological sciences using synchrotron radiation, XFELs, high harmonic generation, electrons and optical lasers. One of CDIs important applications is to probe dynamic phen omena with high spatio-temporal resolution. Here, we report the development of a general in situ CDI method for real-time imaging of dynamic processes in solution. By introducing a time-invariant overlapping region as a real-space constraint, we show that in situ CDI can simultaneously reconstruct a time series of the complex exit wave of dynamic processes with robust and fast convergence. We validate this method using numerical simulations with coherent X-rays and performing experiments on a materials science and a biological specimen in solution with an optical laser. Our numerical simulations further indicate that in situ CDI can potentially reduce the radiation dose by more than an order of magnitude relative to conventional CDI. As coherent X-rays are under rapid development worldwide, we expect in situ CDI could be applied to probe dynamic phenomena ranging from electrochemistry, structural phase transitions, charge transfer, transport, crystal nucleation, melting and fluid dynamics to biological imaging.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا