ترغب بنشر مسار تعليمي؟ اضغط هنا

Focused Ion Beam fabrication of Janus bimetallic cylinders acting as drift~tube Zernike phase plates

116   0   0.0 ( 0 )
 نشر من قبل Paolo Rosi
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Modern nanotechnology techniques offer new opportunities for fabricating structures and devices at the micron and sub-micron level. Here, we use focused ion beam techniques to realize drift tube Zernike phase plates for electrons, whose operation is based on the presence of contact potentials in Janus bimetallic cylinders, in a similar manner to the electrostatic Aharonov-Bohm effect in bimetallic wires. We use electron Fraunhofer interference to demonstrate that such bimetallic pillar structures introduce phase shifts that can be tuned to desired values by varying their dimensions, in particular their heights.

قيم البحث

اقرأ أيضاً

This paper reports on the fabrication and characterization of a high purity monocrystalline diamond detector with buried electrodes realized by the selective damage induced by a focused 6 MeV carbon ion beam scanned over a pattern defined at the micr ometric scale. A suitable variable-thickness mask was deposited on the diamond surface in order to modulate the penetration depth of the ions and to shallow the damage profile toward the surface. After the irradiation, the sample was annealed at high temperature in order to promote the conversion to the graphitic phase of the end-of-range regions which experienced an ion-induced damage exceeding the damage threshold, while recovering the sub-threshold damaged regions to the highly resistive diamond phase. This process provided conductive graphitic electrodes embedded in the insulating diamond matrix; the presence of the variable-thickness mask made the terminations of the channels emerging at the diamond surface and available to be connected to an external electronic circuit. In order to evaluate the quality of this novel microfabrication procedure based on direct ion writing, we performed frontal Ion Beam Induced Charge (IBIC) measurements by raster scanning focused MeV ion beams onto the diamond surface. Charge collection efficiency (CCE) maps were measured at different bias voltages. The interpretation of such maps was based on the Shockley-Ramo-Gunn formalism.
107 - C. J. Edgcombe 2013
Analysis of the imaging of some simple distributions of object phase by a phase plate of Zernike type shows that sharp transitions in the object phase are well transmitted. The low-frequency components of the complete object function are attenuated b y the plate. The behaviour can be characterised by a cut-on parameter defined as the product of the cut-on frequency of the plate and a characteristic dimension of the object. When this parameter exceeds a value of the order of unity, a sharp boundary in the object is imaged by a Zernike plate as a dark lining inside the boundary with a white outline or halo outside the boundary, in agreement with reported observations. The maximum diameter of objects that can be imaged accurately is inversely proportional to the diameter of the hole for beam transmission in the phase plate.
Focused-ion-beam milling is used to fabricate nanostencil masks suitable for the fabrication of magnetic nanostructures relevant for spin transfer torque studies. Nanostencil masks are used to define the device dimensions prior to the growth of the t hin film stack. They consist of a wet etch resistant top layer and an insulator on top of a pre-patterned bottom electrode. The insulator supports a hard mask and gives rise to an undercut by its selective etching. The approach is demonstrated by fabricating current perpendicular to the plane Co/Cu/Co nanopillar junctions, which exhibit current-induced magnetization dynamics.
Modern momentum imaging techniques allow for the investigation of complex molecules in the gas phase by detection of several fragment ions in coincidence. For these studies, it is of great importance that the single-particle detection efficiency e is as high as possible, as the overall efficiency scales with e over n, i.e. the power of the number of detected particles. Here we present measured absolute detection efficiencies for protons of several micro-channel plates (MCPs), including efficiency enhanced funnel MCPs. Furthermore, the relative detection efficiency for two-, three-, four-, and five-body fragmentation of CHBrClF has been examined. The funnel MCPs exhibit an efficiency of approx. 90 percent, gaining a factor of 24 (as compared to normal MCPs) in case of a five-fold ion coincidence detection.
386 - T. Mueller , A. Mlynek , O. Biebel 2009
The influence of fast neutrons on the occupancy and the single tube resolution of ATLAS muon drift detectors was investigated by exposing a chamber built out of 3 layers of 3 short standard drift tubes to neutron flux-densities of up to 16 kHz/cm2 at a neutron energy of E=11 MeV. Pulse shape capable NE213 scintillaton detectors and a calibrated BF3 neutron detector provided monitoring of the neutron flux-density and energy. The sensitivity of the drift chamber to the neutrons was measured to be 4*10-4 by comparing data sets with and without neutron background. For the investigation of tracks of cosmic muons two silicon-strip detectors above and underneath the chamber allow to compare measured drift-radii with reference tracks. Alternatively, the single tube resolution was determined using the triple-sum method. The comparison between data with and without neutron irradiation shows only a marginal effect on the resolution and little influence on the muon track reconstruction.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا