ترغب بنشر مسار تعليمي؟ اضغط هنا

Characterization of SiPM Optical Crosstalk and its Dependence on the Protection-Window Thickness

71   0   0.0 ( 0 )
 نشر من قبل Akira Okumura
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Owing to their high photon detection efficiency, compactness, and low operating voltage, silicon photomultipliers (SiPMs) have found widespread application in many fields, including medical imaging, particle physics, and high-energy astrophysics. However, the so-called optical crosstalk (OCT) phenomenon of SiPMs is a major drawback to their adoption. Secondary infrared photons are emitted inside the silicon substrate spontaneously after the avalanche process caused by the primary incident photons, and they can be detected by the surrounding photodiodes. As a result large output pulses that are equivalent to multiple photoelectrons are observed with a certain probability (OCT rate), even for single-photon events, making the charge resolution worse and increasing the rate of accidental triggers by single-photon events in applications such as atmospheric Cherenkov telescopes. In our previous study, we found that the OCT rates of single-channel SiPMs was dependent on the thickness of their protection resin window, which may be explained by photon propagation inside the resin. In the present study, we measured the OCT rate of a multichannel SiPM and those of neighboring channels caused by photon propagation. Both OCT rates were found to be dependent on the protection-window thickness. We report our OCT measurements of a multichannel SiPM and comparisons with a ray-tracing simulation.

قيم البحث

اقرأ أيضاً

The FemtoDAQ is a low-cost two channel data acquisition system which we have used to investigate the signal characteristics of silicon photomultipliers (SiPMs) coupled to fast scintillators. The FemtoDAQ system can also be used to instrument low cost moderate performance passive detectors, and is suitable for use in harsh environments (e.g., high altitude). The FemtoDAQ is being used as a SiPM test bench for the High Altitude Water Cherenkov (HAWC) Observatory, a TeV gamma ray detector located 4100 m above sea level. Planned upgrades to the HAWC array can benefit greatly from SiPMs, a robust, low-voltage, low-cost alternative to traditional vacuum photomultipliers. The FemtoDAQ is used to power the SiPM detector front end, bias the SiPM, and digitize the photosensor output in a single compact unit.
110 - L.Wang , M.Y.Guan , H.J.Qin 2021
Particle detectors based on liquid argon are now recognised as an attractive technology for dark matter direct detection and coherent elastic neutrino-nucleus scattering measurement. A program using a dual-phase liquid argon detector with a fiducial mass of 200~kg to detect coherent elastic neutrino-nucleus scattering at Taishan Nuclear Power Plant has been proposed. SiPMs will be used as the photon sensor because of their high radio-purity and high photon detection efficiency. S13370-6050CN SiPM, made by Hamamatsu, is a candidate for the detector. In this paper, the characterisation of S13370-6050CN SiPM, including the cross talk and after pulse probabilities at liquid argon temperature and the temperature dependence of break down voltage, dark counting rate and relative quantum efficiency were presented.
This paper describes a comparison of photon detection efficiency and optical crosstalk measurements performed by three partners: Geneva University, Catania Observatory and Nagoya University. The measurements were compared for three different SiPM dev ices with different active areas: from 9 $mm^2$ up to 93.6 $mm^2$ produced by Hamamatsu. The objective of this work is to establish the measurements and analysis procedures for calculating the main SiPM parameters and their precision. This work was done in the scope of SENSE project which aims to build roadmap for the last developments in field of sensors for low light level detection.
70 - E.M. George , P. Ade , K.A. Aird 2012
In January 2012, the 10m South Pole Telescope (SPT) was equipped with a polarization-sensitive camera, SPTpol, in order to measure the polarization anisotropy of the cosmic microwave background (CMB). Measurements of the polarization of the CMB at sm all angular scales (~several arcminutes) can detect the gravitational lensing of the CMB by large scale structure and constrain the sum of the neutrino masses. At large angular scales (~few degrees) CMB measurements can constrain the energy scale of Inflation. SPTpol is a two-color mm-wave camera that consists of 180 polarimeters at 90 GHz and 588 polarimeters at 150 GHz, with each polarimeter consisting of a dual transition edge sensor (TES) bolometers. The full complement of 150 GHz detectors consists of 7 arrays of 84 ortho-mode transducers (OMTs) that are stripline coupled to two TES detectors per OMT, developed by the TRUCE collaboration and fabricated at NIST. Each 90 GHz pixel consists of two antenna-coupled absorbers coupled to two TES detectors, developed with Argonne National Labs. The 1536 total detectors are read out with digital frequency-domain multiplexing (DfMUX). The SPTpol deployment represents the first on-sky tests of both of these detector technologies, and is one of the first deployed instruments using DfMUX readout technology. We present the details of the design, commissioning, deployment, on-sky optical characterization and detector performance of the complete SPTpol focal plane.
We investigate the dependence on length of optical fibres used in astronomy, especially the focal ratio degradation (FRD) which places constraints on the performance of fibre-fed spectrographs used for multiplexed spectroscopy. To this end we present a modified version of the FRD model proposed by Carrasco and Parry cite{Carrasco1994} to quantify the the number of scattering defects within an optical fibre using a single parameter. The model predicts many trends which are seen experimentally, for example, a decrease in FRD as core diameter increases, and also as wavelength increases. However the model also predicts a strong dependence on FRD with length that is not seen experimentally. By adapting the single fibre model to include a second fibre, we can quantify the amount of FRD due to stress caused by the method of termination. By fitting the model to experimental data we find that polishing the fibre causes more stress to be induced in the end of the fibre compared to a simple cleave technique. We estimate that the number of scattering defects caused by polishing is approximately double that produced by cleaving. By placing limits on the end-effect, the model can be used to estimate the residual-length dependence in very long fibres, such as those required for Extremely Large Telescopes (ELTs), without having to carry out costly experiments. We also use our data to compare different methods of fibre termination.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا