ترغب بنشر مسار تعليمي؟ اضغط هنا

A Liquid Hydrogen Target for the MUSE Experiment at PSI

65   0   0.0 ( 0 )
 نشر من قبل Wolfgang Lorenzon
 تاريخ النشر 2019
  مجال البحث فيزياء
والبحث باللغة English
 تأليف P. Roy




اسأل ChatGPT حول البحث

A 280 ml liquid hydrogen target has been constructed and tested for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon-proton and elastic electron-proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. The target cell wall is made of $120,mu$m-thick Kapton, while the beam entrance and exit windows are made of $125,mu$m-thick aluminized Kapton. The side exit windows are made of Mylar laminated on aramid fabric with an areal density of $368,$g/m$^2$. The target system was successfully operated during a commissioning run at PSI at the end of 2018. The target temperature was stable at the 0.01 K level. This suggests a density stability at the $0.02,$% level, which is about a factor of ten better than required.



قيم البحث

اقرأ أيضاً

The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timin g detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of the scattering target, counts the beam flux and precisely times beam particles both to identify species and provide a starting time for time-of-flight measurements. The Beam Monitor, downstream of the scattering target, counts the unscattered beam flux, helps identify background in scattering events, and precisely times beam particles for time-of-flight measurements. The Beam Focus Monitor, mounted on the target ladder under the liquid hydrogen target inside the target vacuum chamber, is used in dedicated runs to sample the beam spot at three points near the target center, where the beam should be focused.
Experiments aiming at measuring the neutron electric dipole moment (nEDM) are at the forefront of precision measurements and demand instrumentation of increasing sensitivity and reliability. In this paper, we report on the development of a dedicated acquisition and control electronics board for the nEDM experiment at the Paul Scherrer Institute (PSI) in Switzerland. This multifunction module is based on a FPGA (Field-programmable gate array) which allows an optimal combination of versatility and evolution capacities.
We present a new powerful liquid hydrogen target developed for the precise study of parity violating electron scattering on hydrogen and deuterium. This target has been designed to have minimal target density fluctuations under the heat load of a 20$ mu$A CW 854.3 MeV electron beam without rastering the electron beam. The target cell has a wide aperture for scattered electrons and is axially symmetric around the beam axis. The construction is optimized to intensify heat exchange by a transverse turbulent mixing in the hydrogen stream, which is directed along the electron beam. The target is constructed as a closed loop circulating system cooled by a helium refrigerator. It is operated by a tangential mechanical pump with an optional natural convection mode. The cooling system supports up to 250 watts of the beam heating removal. Deeply subcooled liquid hydrogen is used for keeping the in-beam temperature below the boiling point. The target density fluctuations are found to be at the level 10$^{-3}$ at a beam current of 20 $mu$A.
The current deuteron beam polarimetry at Nuclotron is provided by the Internal Target polarimeter based on the use of the asymmetry in dp- elastic scattering at large angles in the cms at 270 MeV. The upgraded deuteron beam polarimeter has been used obtain the vector and tensor polarization during 2016/2017 runs for the DSS experimental program. The polarimeter has been used also for tuning of the polarized ion source parameters for 6 different spin modes.
151 - X. G. Cao , X. Chen , Y. H. Chen 2014
PandaX is a large upgradable liquid-xenon detector system that can be used for both direct dark-matter detection and $^{136}$Xe double-beta decay search. It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The detector operate s in dual-phase mode, allowing detection of both prompt scintillation, and ionization charge through proportional scintillation. The central time projection chamber will be staged, with the first stage accommodating a target mass of about 120,kg. In stage II, the target mass will be increased to about 0.5,ton. In the final stage, the detector can be upgraded to a multi-ton target mass. In this paper a detailed description of the stage-I detector design and performance results established during the commissioning phase is presented.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا