ﻻ يوجد ملخص باللغة العربية
PURPOSE: Among the current practices for keratoconus recognition using biomechanical parameters from Corvis ST, matching intra-ocular pressure (IOP) is often required to eliminate the biasing influence; as a result, the combined biomechanical parameters determined from IOP-unmatched scenario possibly bring in confounding influence. This paper was therefore designed to introduce a novel compatible parameter set (CPS) determined from IOP-matched scenario, hopefully could show its compatibility and superiority for recognizing keratoconus in both IOP-matched and not scenarios. METHODS: A total of 335 eyes were included. Among them, 70 eyes were used to determined CPS by forward logistics regression, 62 eyes were used to validate CPS in IOP-matched scenario, and resting 203 eyes were used to validate CPS in IOP-unmatched scenario. To analyze its superiority, CPS was also compared with other two reported Biomechanical Indexes (aCBI and DCR) in both scenarios. Receiver operating characteristic curves (ROC), accuracy, FI, sensitivity and specificity were used to access and compare the performance of these three parameter sets in both scenarios. RESULTS: The resulting CPS was comprised of only 3 biomechanical parameters: DA Ratio Max 1mm (DRM1), the first applanation time (AT1) and an energy loading parameter (Eload). In the IOP-matched validation, the area under ROC (AUC) reached 95.73%, with an accuracy of 95.2%, sensitivity of 93.5% and specificity of 96.8% (leave one out cross-validation). All these indicators reached 96.54%, 95.1%, 95.6% and 94.6% respectively, in the IOP-unmatched validation (leave one out cross-validation). Surprisingly, CPS performed better than other two parameter sets on a whole. CONCLUSIONS: The parameter set determined from IOP-matched scenario indeed exhibit its superiority for differentiation of keratoconus and normal corneas, regardless of IOP-matched or not.
Purpose: This study aimed to investigate the actual changes of central corneal thickness (CCT) in keratoconus and normal corneas during air puff indentation, by using corneal visualization Scheimpflug technology (Corvis ST). Methods: A total of 32 ke
We present two sets of 12 integers that have the same sets of 4-sums. The proof of the fact that a set of 12 numbers is uniquely determined by the set of its 4-sums published 50 years ago is wrong, and we demonstrate an incorrect calculation in it.
Face recognition has been one of the most relevant and explored fields of Biometrics. In real-world applications, face recognition methods usually must deal with scenarios where not all probe individuals were seen during the training phase (open-set
Over the past few decades, researchers have developed several approaches such as the Reference Phantom Method (RPM) to estimate ultrasound attenuation coefficient (AC) and backscatter coefficient (BSC). AC and BSC can help to discriminate pathology f
We generalize the quantum Fisher information flow proposed by Lu textit{et al}. [Phys. Rev. A textbf{82}, 042103 (2010)] to the multi-parameter scenario from the information geometry perspective. A measure named the textit{intrinsic density flow} (ID