Purpose: This study aimed to investigate the actual changes of central corneal thickness (CCT) in keratoconus and normal corneas during air puff indentation, by using corneal visualization Scheimpflug technology (Corvis ST). Methods: A total of 32 keratoconic eyes and 46 normal eyes were included in this study. Three parameters of CCTinitial, CCTfinal and CCTpeak were selected to represent the CCT at initial time, final time and highest corneal concavity, respectively, during air puff indentation. Wilcoxon signed rank test (paired sample test) was used to assess the differences between these 3 parameters in both keratoconus and normal groups. Univariate linear regression analysis was performed to determine the effect of CCTinitial on CCTpeak and CCTfinal, as well as the impact of air puff force on CCT in each group. Receiver operating characteristic (ROC) curves were constructed to evaluate the discriminative ability of the 3 parameters. Results: The results demonstrated that CCTpeak and CCTfinal were significantly decreased (p<0.01) compared to CCTinitial in both keratoconus and normal groups. Regression analysis indicated a significant positive correlation between CCTpeak and CCTinitial in normal cornea group (R2=0.337, p<0.01), but not in keratoconus group (R2=0.029, p=0.187). Likewise, regression models of air puff force and CCT revealed the different patterns of CCT changes between keratoconus and normal cornea groups. Furthermore, ROC curves showed that CCTpeak exhibited the greatest AUC (area under ROC curve) of 0.940, with accuracy, sensitivity and specificity of 94.9%, 87.5% and 100%, respectively. Conclusions: CCT may change during air puff indentation, and is significantly different between keratoconus and normal cornea groups. The changing pattern is useful for the diagnosis of keratoconus, and lays the foundation for corneal biomechanics.
PURPOSE: Among the current practices for keratoconus recognition using biomechanical parameters from Corvis ST, matching intra-ocular pressure (IOP) is often required to eliminate the biasing influence; as a result, the combined biomechanical paramet
Corneal thickness (pachymetry) maps can be used to monitor restoration of corneal endothelial function, for example after Descemets membrane endothelial keratoplasty (DMEK). Automated delineation of the corneal interfaces in anterior segment optical
The classical models of Hertz, Sneddon and Boussinesq provide solutions for problems of indentation of a semi-infinite elastic massif by a sphere, a sphere or a cone and a flat punch. Although these models have been widely tested, it appears that at
Dementia disorders are increasingly becoming sources of a broad range of problems, strongly interfering with normal daily tasks of a growing number of individuals. Such neurodegenerative diseases are often accompanied with progressive brain atrophy t
In the COVID-19 period, the number of deaths has increased every day around the world. The pandemic has impacted the life and economy. Especially, there is a shortage in medical including a lack of technology, facility and equipment. One of those, ve