ترغب بنشر مسار تعليمي؟ اضغط هنا

Multiple intrabeam scattering in X-Y coupled focusing systrems

59   0   0.0 ( 0 )
 نشر من قبل Sergei Nagaitsev
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

This paper describes an analytical theory to calculate the emittance growth rates due to intrabeam scattering in focusing systems with arbitrary x-y coupling. The presented results are based on calculations of average emittance growth rates for an initially Gaussian distribution.



قيم البحث

اقرأ أيضاً

120 - K.L.F. Bane 2001
At the Accelerator Test Facility (ATF) at KEK intrabeam scattering (IBS) is a strong effect for an electron machine. It is an effect that couples all dimensions of the beam, and in April 2000, over a short period of time, all dimensions were measured as functions of current. In this report we derive a simple relation for the growth rates of emittances due to IBS. We apply the theories of Bjorken-Mtingwa, Piwinski, and a formula due to Raubenheimer to the ATF parameters, and find that the results all agree (if in Piwinskis formalism we replace the dispersion squared over beta by the dispersion invariant). Finally, we compare theory, including the effect of potential well bunch lengthening, with the April 2000 measurements, and find reasonably good agreement in the energy spread and horizontal emittance dependence on current. The vertical emittance measurement, however, implies that either: there is error in the measurement (equivalent to an introduction of 0.6% x-y coupling error), or the effect of intrabeam scattering is stronger than predicted (35% stronger in growth rates).
62 - K. Bane , H. Hayano , K. Kubo 2000
In April 2000 the single bunch energy spread, bunch length, horizontal emittance, and vertical emittance were measured as functions of current in KEKs ATF damping ring. In this report the measurement results are analyzed in light of intrabeam scatter ing theory. The measurements are found to be relatively consistent with theory, although the measured effects appear to be stronger than theory. In addition, the factor of 3 growth in vertical emittance at a current of 3 mA does not seem to be supported.
229 - K.L.F. Bane 2002
We derive a simple relation for estimating the relative emittance growth in x and y due to intrabeam scattering (IBS) in electron storage rings. We show that IBS calculations for the ATF damping ring, when using the formalism of Bjorken-Mtingwa, a mo dified formalism of Piwinski (where eta squared divided by beta has been replaced by the dispersion invariant), or a simple high-energy approximate formula all give results that agree well. Comparing theory, including the effect of potential well bunch lengthening, with a complete set of ATF steady-state beam size vs. current measurements we find reasonably good agreement for energy spread and horizontal emittance. The measured vertical emittance, however, is larger than theory in both offset (zero current emittance) and slope (emittance change with current). The slope error indicates measurement error and/or additional current-dependent physics at the ATF; the offset error, that the assumed Coulomb log is correct to within a factor of 1.75.
We observed reduction of multiple Coulomb scattering of 855 MeV electrons within a Si crystalline plate w.r.t. an amorphous plate with the same mass thickness. The reduction owed to complete or partial suppression of the coherent part of multiple sca ttering in a crystal vs crystal orientation with the beam. Experimental data were collected at Mainz Mikrotron and critically compared to theoretical predictions and Monte Carlo simulations. Our results highlighted maximal 7 % reduction of the r.m.s. scattering angle at certain beam alignment with the [100] crystal axes. However, partial reduction was recorded over a wide range of alignment of the electron beam with the crystal up to 15 deg. This evidence may be relevant to refine the modelling of multiple scattering in crystals for currently used software, which is interesting for detectors in nuclear, medical, high energy physics.
115 - I. Agapov 2013
In present work we investigate the potential of a longitudinally focusing device to compress bunches passing an undulator for a synchrotron storage ring. If integrated into a storage ring similar to PETRAIII such device could potentially produce cont inuous $sim$1ps pulses of photons in the $nm$ range with peak pulse powers of tens of GW. Even without operating in FEL saturation mode the longitudinal focusing can provide means to increase the brightness and shorten the photon pulse length.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا