POLICAN: A Near-infrared Imaging Polarimeter at the 2.1m OAGH Telescope

61   0   0.0 ( 0 )
 نشر من قبل Devaraj Rangaswamy
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

POLICAN is a near-infrared imaging linear polarimeter developed for the Cananea Near-infrared Camera (CANICA) at the 2.1m telescope of the Guillermo Haro Astrophysical Observatory (OAGH) located in Cananea, Sonora, Mexico. POLICAN is mounted ahead of CANICA and consist of a rotating super-achromatic 1-2.7 micron half-wave plate (HWP) as the modulator and a fixed wire-grid polarizer as the analyzer. CANICA has a 1024 x 1024 HgCdTe detector with a plate scale of 0.32 arcsec/pixel and provides a field of view of 5.5 x 5.5 arcmin^2. The polarimetric observations are carried out by modulating the incoming light through different steps of half-wave plate angles 0, 22.5, 45, 67.5 deg, to establish linear Stokes parameters (I, Q, and U). Image reduction consists of dark subtraction, polarimetric flat fielding, and sky subtraction. The astrometry and photometric calibrations are performed using the publicly available data from the Two Micron All Sky Survey. Polarimetric calibration includes observations of globular clusters and polarization standards available in the literature. Analysis of multiple observations of globular clusters yielded an instrumental polarization of 0.51%. Uncertainties in polarization range from 0.1% to 10% from the brightest 7 mag to faintest 16 mag stars. The polarimetric accuracy achieved is better than 0.5% and the position angle errors less than 5 deg for stars brighter than 13 mag in H-band. POLICAN is mainly being used to study the scattered polarization and magnetic fields in and around star-forming regions of the interstellar medium.



قيم البحث

اقرأ أيضاً

A polarimeter has been built for use with the Submillimetre Common-User Bolometer Array (SCUBA), on the James Clerk Maxwell Telescope (JCMT) in Hawaii. SCUBA is the first of a new generation of highly sensitive submillimetre cameras, and the UK/Japan Polarimeter adds a polarimetric imaging/photometry capability in the wavelength range 350 to 2000 microns. Early science results range from measuring the synchrotron polarization of the black hole candidate Sgr A* to mapping magnetic fields inferred from polarized dust emission in Galactic star-forming clouds. We describe the instrument design, performance, observing techniques and data reduction processes, along with an assessment of the current and future scientific capability.
125 - T. Baug , D.K. Ojha , S.K. Ghosh 2018
TIFR Near Infrared Imaging Camera-II is a closed-cycle Helium cryo-cooled imaging camera equipped with a Raytheon 512 x 512 pixels InSb Aladdin III Quadrant focal plane array having sensitivity to photons in the 1-5 microns wavelength band. In this p aper, we present the performance of the camera on the newly installed 3.6-m Devasthal Optical Telescope (DOT) based on the calibration observations carried out during 2017 May 11-14 and 2017 October 7-31. After the preliminary characterization, the camera has been released to the Indian and Belgian astronomical community for science observations since 2017 May. The camera offers a field-of-view of ~86.5 arcsec x 86.5 arcsec on the DOT with a pixel scale of 0.169 arcsec. The seeing at the telescope site in the near-infrared bands is typically sub-arcsecond with the best seeing of ~0.45 arcsec realized in the near-infrared K-band on 2017 October 16. The camera is found to be capable of deep observations in the J, H and K bands comparable to other 4-m class telescopes available world-wide. Another highlight of this camera is the observational capability for sources up to Wide-field Infrared Survey Explorer (WISE) W1-band (3.4 microns) magnitudes of 9.2 in the narrow L-band (nbL; lambda_{cen} ~3.59 microns). Hence, the camera could be a good complementary instrument to observe the bright nbL-band sources that are saturated in the Spitzer-Infrared Array Camera ([3.6] <= 7.92 mag) and the WISE W1-band ([3.4] <= 8.1 mag). Sources with strong polycyclic aromatic hydrocarbon (PAH) emission at 3.3 microns are also detected. Details of the observations and estimated parameters are presented in this paper.
Near-infrared Imager Spectrometer and Polarimeter (NISP) is a camera, an intermediate resolution spectrograph and an imaging polarimeter being developed for upcoming 2.5m telescope of Physical Research Laboratory at Mount Abu, India. NISP is designed to work in the Near-IR (0.8-2.5 micron) using a H2RG detector. Collimator and camera lenses would transfer the image from the focal plane of the telescope to the detector plane. The entire optics, mechanical support structures, detector-SIDECAR assembly will be cooled to cryo-temperatures using an open cycle Liquid Nitrogen tank inside a vacuum Dewar. GFRP support structures would be used to isolate cryogenic system from the Dewar. Two layer thermal shielding would be used to reduce the radiative heat transfer. Molecular sieve (getter) would be used to enhance the vacuum level inside Dewar. Magnet-reedswitch combination are used for absolute positioning of filterwheels. Here we describe the mechanical aspects in detail.
58 - Archita Rai 2020
As a Near-IR instrument to PRLs upcoming 2.5 m telescope, NISP is designed indigeniously at PRL to serve as a multifaceted instrument. Optical, Mechanical and Electronics subsystems are being designed and developed in-house at PRL. It will consist of imaging, spectroscopy and imaging-polarimetry mode in the wavelength bands Y, J, H, Ks i.e. 0.8 - 2.5 micron. The detector is an 2K x 2K H2RG (MCT) array detector from Teledyne, which will give a large FOV of 10 x 10 in the imaging mode. Spectroscopic modes with resolving power of R ~ 3000, will be achieved using grisms. Spectroscopy will be available in single order and a cross-dispersed mode shall be planned for simultaneous spectra. The instrument enables multi-wavelength imaging-polarimetry using Wedged-Double Wollaston (WeDoWo) prisms to get single shot Stokes parameters (I, Q, U) for linear polarisation simultaneously, thus increasing the efficiency of polarisation measurements and reducing observation time.
NISP, a multifaceted near-infrared instrument for the upcoming 2.5m IR telescope at MIRO Gurushikhar, Mount Abu, Rajasthan, India is being developed at PRL, Ahmedabad. NISP will have wide (FOV = 10 x 10) field imaging, moderate (R=3000) spectroscopy and imaging polarimetry operating modes. It is designed based on 0.8 to 2.5 micron sensitive, 2048 X 2048 HgCdTe (MCT) array detector from Teledyne. Optical, Mechanical and Electronics subsystems are being designed and developed in-house at PRL. HAWAII-2RG (H2RG) detector will be mounted along with controlling SIDECAR ASIC inside LN2 filled cryogenic cooled Dewar. FPGA based controller for H2RG and ASIC will be mounted outside the Dewar at room temperature. Smart stepper motors will facilitate motion of filter wheels and optical components to realize different operating modes. Detector and ASIC temperatures are servo controlled using Lakeshores Temperature Controller (TC) 336. Also, several cryogenic temperatures will be monitored by TC for health checking of the instrument. Detector, Motion and Temperature controllers onboard telescope will be interfaced to USB Hub and fiber-optic trans-receiver. Remote Host computer interface to remote end trans-receiver will be equipped with in-house developed GUI software to control all functionalities of NISP. Design and development aspects of NISP Electronics will be presented in this conference.