ترغب بنشر مسار تعليمي؟ اضغط هنا

Systematic Uncertainties in RF-Based Measurement of Superconducting Cavity Quality Factors

56   0   0.0 ( 0 )
 نشر من قبل Jeremiah Holzbauer
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Q0 determinations based on RF power measurements are subject to at least three potentially large systematic effects that have not been previously appreciated. Instrumental factors that can systematically bias RF based measurements of Q0 are quantified and steps that can be taken to improve the determination of Q0 are discussed.

قيم البحث

اقرأ أيضاً

78 - J.P. Holzbauer 2018
SRF cavity quality factors can be accurately measured using RF-power based techniques only when the cavity is very close to critically coupled. This limitation is from systematic errors driven by non-ideal RF components. When the cavity is not close to critically coupled, these systematic effects limit the accuracy of the measurements. The combination of the complex base-band envelopes of the cavity RF signals in combination with a trombone in the circuit allow the relative calibration of the RF signals to be extracted from the data and systematic effects to be characterized and suppressed. The improved calibration allows accurate measurements to be made over a much wider range of couplings. Demonstration of these techniques during testing of a single-spoke resonator with a coupling factor of near 7 will be presented, along with recommendations for application of these techniques.
Higher-order mode (HOM) based intra-cavity beam diagnostics has been proved effectively and conveniently in superconducting radio-frequency (SRF) accelerators. Our recent research shows that the beam harmonics in the bunch train excited HOM spectrum, which have much higher signal-to-noise ratio than the intrinsic HOM peaks, may also be useful for beam diagnostics. In this paper, we will present our study on bunch train excited HOMs, including the theoretic model and recent experiments carried out based on the DC-SRF photoinjector and SRF linac at Peking University.
We develop a lower critical field (Hc1) measurement system using the third-harmonic response of an applied AC magnetic field from a solenoid coil positioned above a superconducting sample. Parameter Hc1 is measured via detection of the third-harmonic component, which drastically changes when a vortex begins to penetrate the superconductor with temperature increase. The magnetic field locally applied to one side of the sample mimics the magnetic field within superconducting radio-frequency (SRF) cavities and prevents edge effects of the superconducting sample. With this approach, our measurement system can potentially characterize surface-engineered SRF materials such as Superconductor-Insulator-Superconductor multilayer structure (S-I-S structure). As a validation test, we measure the temperature dependence of Hc1 of two high-RRR bulk Nb samples and obtain results consistent with the literature. We also confirm that our system can apply magnetic fields of at least 120 mT at 4-5 K without any problem of heat generation of the coil. This field value is higher than those reported in previous works and makes it possible to more accurately estimate Hc1 at lower temperatures.
A 56 MHz superconducting RF cavity was designed and installed in the Relativistic Heavy Ion Collider (RHIC). It is the first superconducting quarter wave resonator (QWR) operating in a high-energy storage ring. We discuss herein the cavity operation with Au+Au collisions, and with asymmetrical Au+He3 collisions. The cavity is a storage cavity, meaning that it becomes active only at the energy of experiment, after the acceleration cycle is completed. With the cavity at 300 kV, an improvement in luminosity was detected from direct measurements, and the bunch length has been reduced. The uniqueness of the QWR demands an innovative design of the higher order mode dampers with high-pass filters, and a distinctive fundamental mode damper that enables the cavity to be bypassed during the acceleration stage.
Ambient magnetic field, if trapped in the penetration depth, leads to the residual resistance and therefore sets the limit for the achievable quality factors in superconducting niobium resonators for particle accelerators. Here we show that a complet e expulsion of the magnetic flux can be performed and leads to: 1) record quality factors $Q > 2times10^{11}$ up to accelerating gradient of 22 MV/m; 2) $Qsim3times10^{10}$ at 2 K and 16 MV/m in up to 190 mG magnetic fields. This is achieved by large thermal gradients at the normal/superconducting phase front during the cooldown. Our findings open up a way to ultra-high quality factors at low temperatures and show an alternative to the sophisticated magnetic shielding implemented in modern superconducting accelerators.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا