ﻻ يوجد ملخص باللغة العربية
We develop a lower critical field (Hc1) measurement system using the third-harmonic response of an applied AC magnetic field from a solenoid coil positioned above a superconducting sample. Parameter Hc1 is measured via detection of the third-harmonic component, which drastically changes when a vortex begins to penetrate the superconductor with temperature increase. The magnetic field locally applied to one side of the sample mimics the magnetic field within superconducting radio-frequency (SRF) cavities and prevents edge effects of the superconducting sample. With this approach, our measurement system can potentially characterize surface-engineered SRF materials such as Superconductor-Insulator-Superconductor multilayer structure (S-I-S structure). As a validation test, we measure the temperature dependence of Hc1 of two high-RRR bulk Nb samples and obtain results consistent with the literature. We also confirm that our system can apply magnetic fields of at least 120 mT at 4-5 K without any problem of heat generation of the coil. This field value is higher than those reported in previous works and makes it possible to more accurately estimate Hc1 at lower temperatures.
The multilayer thin film structure of the superconductor has been proposed by A. Gurevich to enhance the maximum gradient of SRF cavities. The lower critical field Hc1 at which the vortex starts penetrating the superconducting material will be improv
A comment to the authors SRF Conference pre-print [1] was submitted by A. Gurevich to the arXiv [2]. In this response, we show that the arguments used in the comment are not valid. [1] arXiv:1309.3239 [2] arXiv:1309.5626
Q0 determinations based on RF power measurements are subject to at least three potentially large systematic effects that have not been previously appreciated. Instrumental factors that can systematically bias RF based measurements of Q0 are quantifie
We report a strong effect of the cooling dynamics through $T_mathrm{c}$ on the amount of trapped external magnetic flux in superconducting niobium cavities. The effect is similar for fine grain and single crystal niobium and all surface treatments in
The temperature behaviour of the first critical field ($B_{C1}$) of superconducting thin film samples can be determined with high accuracy using an inductive and contactless method. Driving a sinusoidal current in a single coil placed in front of the