ترغب بنشر مسار تعليمي؟ اضغط هنا

New Design Study and Related Experimental Program for the LCLS RF Photoinjector

108   0   0.0 ( 0 )
 نشر من قبل J. E. Clendenin
 تاريخ النشر 2000
  مجال البحث فيزياء
والبحث باللغة English
 تأليف M. Ferrario




اسأل ChatGPT حول البحث

We report the results of a recent beam dynamics study, motivated by the need to redesign the LCLS photoinjector, that lead to the discovery of a new effective working point for a split RF photoinjector. We consider the emittance compensation regime of a space charge beam: by increasing the solenoid strength, the emittance evolution shows a double minimum behavior in the drifting region. If the booster is located where the relative emittance maximum and the envelope waist occur, the second emittance minimum can be shifted to the booster exit and frozen at a very low level (0.3 mm-mrad for a 1 nC flat top bunch), to the extent that the invariant envelope matching conditions are satisfied. Standing Wave Structures or alternatively Traveling Wave Structures embedded in a Long Solenoid are both candidates as booster linac. A careful measurement of the emittance evolution as a function of position in the drifting region is necessary to verify the computation and to determine experimentally the proper position of the booster cavities. The new design study and supporting experimental program under way at the SLAC Gun Test Facility are discussed.

قيم البحث

اقرأ أيضاً

The design of the Linac Coherent Light Source assumes that a low-emittance, 1-nC, 10-ps beam will be available for injection into the 15-GeV linac. The proposed rf photocathode injector that will provide a 150-MeV beam with rms normalized emittances of 1 mm in both the transverse and longitudinal dimensions is based on a 1.6-cell S-band rf gun that is equipped with an emittance compensating solenoid. The booster accelerator is positioned at the beam waist coinciding with the first emittance maximum and is provided with an accelerating gradient of ~25 MeV/m, i.e., the new working point. The uv pulses required for cathode excitation will be generated by tripling the output of a Ti:sapphire laser system consisting of a highly stable cw mode-locked oscillator and two bow-tie amplifiers pumped by a pair of Q-switched Nd:YAG lasers. The large bandwidth of the Ti:sapphire system accommodates the desired temporal pulse shaping. Details of the design and the supporting simulations are presented.
72 - R. Akre , V. Bharadwaj , P. Emma 2000
The Linac Coherent Light Source (LCLS) project at SLAC uses a dense 15 GeV electron beam passing through a long undulator to generate extremely bright x-rays at 1.5 angstroms. The project requires electron bunches with a nominal peak current of 3.5kA and bunch lengths of 0.020mm (70fs). The bunch compression techniques used to achieve the high brightness impose challenging tolerances on the accelerator RF phase and amplitude. The results of measurements on the existing SLAC linac RF phase and amplitude stability are summarised and improvements needed to meet the LCLS tolerances are discussed.
Polarized electron beams are now in routine use in particle accelerators for nuclear and high energy physics experiments. These beams are presently produced by dc-biased photoelectron sources combined with rf chopping and bunching systems with inhere ntly high transverse emittances. Low emittances can be produced with an rf gun, but the vacuum environment has until now been considered too harsh to support a negative electron affinity GaAs photocathode. We propose to significantly improve the vacuum conditions by adapting a PWT rf photoinjector to achieve reasonable cathode emission rates and lifetimes. This adaptation can also be combined with special optics that will result in a flat beam with a normalized rms emittance in the narrow dimension that may be as low as 10-8 m.
76 - O. Mete , K. Hanahoe , G. Xia 2015
PARS (Plasma Acceleration Research Station) is an electron beam driven plasma wakefield acceleration test stand proposed for VELA/CLARA facility in Daresbury Laboratory. In order to optimise various operational configurations, 2D numerical studies we re performed by using VSIM for a range of parameters such as bunch length, radius, plasma density and positioning of the bunches with respect to each other for the two-beam acceleration scheme. In this paper, some of these numerical studies and considered measurement methods are presented.
Proposed fourth generation light sources using SASE FELs to generate short pulse, coherent, X-rays require demonstration of high brightness electron sources. The Gun Test Facility (GTF) at SLAC was built to test high brightness sources for the propos ed Linac Coherent Light Source at SLAC. The transverse emittance measurements are made at nearly 30 MeV by measuring the spot size on a YAG screen using the quadrupole scan technique. The emittance was measured to vary from 1 to 3.5 mm-mrad as the charge is increased from 50 to 350 pC using a laser pulse width of 2 ps FWHM. The measurements are in good agreement with simulation results using the LANL version of PARMELA.