ترغب بنشر مسار تعليمي؟ اضغط هنا

The sub-millimetre non-uniformity measurement of residual and coil-generated field in the magnetic shield using atomic vapor cell

95   0   0.0 ( 0 )
 نشر من قبل Chen Liu
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Magnetic field source localization and imaging happen at different scales. The sensing baseline ranges from meter scale such as magnetic anomaly detection, centimeter scale such as brain field imaging to nanometer scale such as the imaging of magnetic skyrmion and single cell. Here we show how atomic vapor cell can be used to realize a baseline of 109.6 {mu}m with a magnetic sensitivity of 10pT/sqrt(Hz)@0.6-100Hz and a dynamic range of 2062-4124nT.We use free induction decay (FID) scheme to suppress low-frequency noise and avoid scale factor variation for different domains due to light non-uniformity. The measurement domains are scanned by digital micro-mirror device (DMD). The currents of 22mA, 30mA, 38mA and 44mA are applied in the coils to generate different fields along the pumping axis which are measured respectively by fitting the FID signals of the probe light. The residual fields of every domain are obtained from the intercept of linearly-fitting of the measurement data corresponding to these four currents. The coil-generated fields are calculated by deducting the residual fields from the total fields. The results demonstrate that the hole of shield affects both the residual and the coil-generated field distribution. The potential impact of field distribution measurement with an outstanding comprehensive properties of spatial resolution, sensitivity and dynamic range is far-reaching. It could lead to capability of 3D magnetography for small stuffs and/or organs in millimeter or even smaller scale.



قيم البحث

اقرأ أيضاً

We use an atomic vapor cell as a frequency tunable microwave field detector operating at frequencies from GHz to tens of GHz. We detect microwave magnetic fields from 2.3 GHz to 26.4 GHz, and measure the amplitude of the sigma+ component of an 18 GHz microwave field. Our proof-of-principle demonstration represents a four orders of magnitude extension of the frequency tunable range of atomic magnetometers from their previous dc to several MHz range. When integrated with a high resolution microwave imaging system, this will allow for the complete reconstruction of the vector components of a microwave magnetic field and the relative phase between them. Potential applications include near-field characterisation of microwave circuitry and devices, and medical microwave sensing and imaging.
We have implemented the so-called $lambda$-Zeeman technique (LZT) to investigate individual hyperfine transitions between Zeeman sublevels of the Rb atoms in a strong external magnetic field $B$ in the range of $2500 - 5000$ G (recently it was establ ished that LZT is very convenient for the range of $10 - 2500$ G). Atoms are confined in a nanometric thin cell (NTC) with the thickness $L = lambda$, where $lambda$ is the resonant wavelength 794 nm for Rb $D_1$ line. Narrow velocity selective optical pumping (VSOP) resonances in the transmission spectrum of the NTC are split into several components in a magnetic field with the frequency positions and transition probabilities depending on the $B$-field. Possible applications are described, such as magnetometers with nanometric local spatial resolution and tunable atomic frequency references.
The sub-natural-width $N$-type resonance in {Lambda}-system, on the $D_2$ line of Cs atoms is studied for the first time in the presence of a buffer gas (neon) and the radiations of two continuous narrow band diode lasers. $L$ = 1 cm long cell is use d to investigate $N$-type process. The $N$-type resonance in a magnetic field for $^{133}$Cs atoms is shown to split into seven or eight components, depending on the magnetic field and laser radiation directions. The results obtained indicate that levels $F_g$ = 3, 4 are initial and final in the N resonance formation. The experimental results with magnetic field agree well with the theoretical curves.
The design and performance of a compact heated vapor cell unit for realizing a dichroic atomic vapor laser lock (DAVLL) for the D2 transitions in atomic rubidium is described. A 5 cm-long vapor cell is placed in a double-solenoid arrangement to produ ce the required magnetic field; the heat from the solenoid is used to increase the vapor pressure and correspondingly the DAVLL signal. We have characterized experimentally the dependence of important features of the DAVLL signal on magnetic field and cell temperature. For the weaker transitions both the amplitude and gradient of the signal are increased by an order of magnitude.
We demonstrate a high-performance coherent-population-trapping (CPT) Cs vapor cell atomic clock using the push-pull optical pumping technique (PPOP) in the pulsed regime, allowing the detection of high-contrast and narrow Ramsey-CPT fringes. The impa ct of several experimental parameters onto the clock resonance and short-term fractional frequency stability, including the laser power, the cell temperature and the Ramsey sequence parameters, has been investigated. We observe and explain the existence of a slight dependence on laser power of the central Ramsey-CPT fringe line-width in the pulsed regime. We report also that the central fringe line-width is commonly narrower than the expected Ramsey line-width given by $1/(2T_R)$, with $T_R$ the free-evolution time, for short values of $T_R$. The clock demonstrates a short-term fractional frequency stability at the level of $2.3 times 10^{-13}~tau^{-1/2}$ up to 100 seconds averaging time, mainly limited by the laser AM noise. Comparable performances are obtained in the conventional continuous (CW) regime, if use of an additional laser power stabilization setup. The pulsed interaction allows to reduce significantly the clock frequency sensitivity to laser power variations, especially for high values of $T_R$. This pulsed CPT clock, ranking among the best microwave vapor cell atomic frequency standards, could find applications in telecommunication, instrumentation, defense or satellite-based navigation systems.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا