ترغب بنشر مسار تعليمي؟ اضغط هنا

Single Harmonic-based Narrowband Magnetic Particle Imaging

238   0   0.0 ( 0 )
 نشر من قبل Jing Zhong
 تاريخ النشر 2021
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Visualization of the in vivo spatial distribution of superparamagnetic iron oxide nanoparticles (SPIONs) is crucial to biomedicine. Magnetic particle imaging (MPI) is one of the most promising approaches for direct measurements of the SPION distribution. In this paper, we systematically investigate a single-harmonic-based narrowband MPI approach. Herein, only the 3rd harmonic at 15 kHz of the SPION signal induced in an excitation magnetic field of 5 kHz is measured via a narrowband detection system for imaging during scanning a field-free-point in a field of view. Experiments on spot and line phantoms are performed to evaluate the spatial distribution by the assessment of the full width at half maximum and modulation transfer function at different excitation magnetic fields from 4 to 10 mT. Experimental results demonstrate that reconstructed images have a spatial resolution of 1.6 and 1.5 mm for a gradient field of 2.2 T/m and 4.4 T/m in x- and z-direction, respectively, at an excitation magnetic field of 4 mT. In terms of line gap, two lines with a gap of 0.5 mm are resolved. With increasing the excitation magnetic field to 10 mT, the spatial resolution gets worse to 2.4 and 2.0 mm in x- and z-direction, respectively. Moreover, the custom-built MPI scanner allows a limit of detection of 53 microgram (Fe)/mL (500 ng Fe weight) using perimag SPIONs. In addition, the excellent performance is demonstrated by imaging experiments on an emg logo phantom. We believe that the proposed narrowband MPI approach is a promising approach for SPION imaging.

قيم البحث

اقرأ أيضاً

An extensive comparison of the path uncertainty in single particle tracking systems for ion imaging was carried out based on Monte Carlo simulations. The spatial resolution as function of system parameters such as geometry, detector properties and th e energy of proton and helium beams was investigated to serve as a guideline for hardware developments. Primary particle paths were sampled within a water volume and compared to the most likely path estimate obtained from detector measurements, yielding a depth-dependent uncertainty envelope. The maximum uncertainty along this curve was converted to a conservative estimate of the minimal radiographic pixel spacing for a single set of parameter values. Simulations with various parameter settings were analysed to obtain an overview of the reachable pixel spacing as function of system parameters. The results were used to determine intervals of detector material budget and position resolution that yield a pixel spacing small enough for clinical dose calculation. To ensure a pixel spacing below 2 mm, the material budget of a detector should remain below 0.25 % for a position resolution of 200 $mathrm{mu m}$ or below 0.75 % for a resolution of 10 $mathrm{mu m}$. Using protons, a sub-millimetre pixel size could not be achieved for a phantom size of 300 mm or at a large clearance. With helium ions, a sub-millimetre pixel spacing could be achieved even for a large phantom size and clearance, provided the position resolution was less than 100 $mathrm{mu m}$ and material budget was below 0.75 %.
The use of engineered nanoscale magnetic materials in healthcare and biomedical technologies is rapidly growing. Two examples which have recently attracted significant attention are magnetic particle imaging (MPI) for biological monitoring, and magne tic field hyperthermia (MFH) for cancer therapy. Here for the first time, the capability of a Lissajous scanning MPI device to act as a standalone platform to support the application of MFH cancer treatment is presented. The platform is shown to offer functionalities for nanoparticle localization, focused hyperthermia therapy application, and non-invasive tissue thermometry in one device. Combined, these capabilities have the potential to significantly enhance the accuracy, effectiveness and safety of MFH therapy. Measurements of nanoparticle hyperthermia during protracted exposure to the MPI scanners 3D imaging field sequence revealed spatially focused heating, with a maximum that is significantly enhanced compared with a simple 1-dimensional sinusoidal excitation. The observed spatial heating behavior is qualitatively described based on a phenomenological model considering torques exerted in the Brownian regime. In-vitro cell studies using a human acute monocytic leukemia cell line (THP-1) demonstrated strong suppression of both structural integrity and metabolic activity within 24 h following a 40 min MFH treatment actuated within the Lissajous MPI scanner. Furthermore, reconstructed MPI images of the nanoparticles distributed among the cells, and the temperature-sensitivity of the MPI imaging signal obtained during treatment are demonstrated. In summary, combined Lissajous MPI and MFH technologies are presented; demonstrating for the first time their potential for cancer treatment with maximum effectiveness, and minimal collateral damage to surrounding tissues.
Over the past few decades, researchers have developed several approaches such as the Reference Phantom Method (RPM) to estimate ultrasound attenuation coefficient (AC) and backscatter coefficient (BSC). AC and BSC can help to discriminate pathology f rom normal tissue during in-vivo imaging. In this paper, we propose a new RPM model to simultaneously compute AC and BSC for harmonic imaging and a normalized score that combines the two parameters as a measure of disease progression. The model utilizes the spectral difference between two regions of interest, the first, a proximal, close to the probe and second, a distal, away from the probe. We have implemented an algorithm based on the model and shown that it provides accurate and stable estimates to within 5% of AC and BSC for simulated received echo from post-focal depths of a homogeneous liver-like medium. For practical applications with time gain and time frequency compensated in-phase and quadrature (IQ) data from ultrasound scanner, the method has been approximated and generalized to estimate AC and BSC for tissue layer underlying a more attenuative subcutaneous layer. The angular spectrum approach for ultrasound propagation in biological tissue is employed as a virtual Reference Phantom (VRP). The VRP is calibrated with a fixed probe and scanning protocol for application to liver tissue. In a feasibility study with 16 subjects, the method is able to separate 9/11 cases of progressive non-alcoholic fatty liver disease from 5 normal. In particular, it is able to separate 4/5 cases of non-alcoholic steato-hepatitis and early fibrosis (F<=2) from normal tissue. More extensive clinical studies are needed to assess the full capability of this model for screening and monitoring disease progression in liver and other tissues.
The thick GEM (THGEM) [1] is an expanded GEM, economically produced in the PCB industry by simple drilling and etching in G-10 or other insulating materials (fig. 1). Similar to GEM, its operation is based on electron gas avalanche multiplication in sub-mm holes, resulting in very high gain and fast signals. Due to its large hole size, the THGEM is particularly efficient in transporting the electrons into and from the holes, leading to efficient single-electron detection and effective cascaded operation. The THGEM provides true pixilated radiation localization, ns signals, high gain and high rate capability. For a comprehensive summary of the THGEM properties, the reader is referred to [2, 3]. In this article we present a summary of our recent study on THGEM-based imaging, carried out with a 10x10 cm^2 double-THGEM detector.
83 - H. Yan , K. Liao , Z. Deng 2014
Lights wave-particle duality is at the heart of quantum mechanics and can be well illustrated by Wheelers delayed-choice experiment. The choice of inserting or removing the second classical (quantum) beam splitter in a Mach-Zehnder interferometer det ermines the classical (quantum) wave-particle behaviors of a photon. In this paper, we report our experiment using the classical beam splitter to observe the simultaneous wave-particle behaviors in the wave-packet of a narrowband single photon. This observation suggests that it is necessary to generalize the current quantum wave-particle duality theory. Our experiment demonstrates that the produced wave-particle state can be considered an additional degree of freedom and can be utilized in encoding quantum information.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا