ترغب بنشر مسار تعليمي؟ اضغط هنا

Heat radiation reduction in the cryostat with multilayer insulation technique

52   0   0.0 ( 0 )
 نشر من قبل Venktesh Singh Dr
 تاريخ النشر 2020
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

Multilayer insulation (MLI) is an important technique for the reduction of radiation heat load in cryostats. The present work is focused on investigation for the selection of suitable reflective layer and spacer material in MLI systems. In our analysis, we have selected perforated double-Aluminized Mylar (DAM) with Dacron, unperforated DAM with Silk-net and perforated DAM with Glass-tissue for their evaluation as the reflective layer as well as spacer materials in MLI technique. Current work would discuss the calculation of the effect of layer density and the number of layers on the heat load. Knowing the key parameters of MLI, we have compared the heat load generation in spherical as well as cylindrical cryostats and the effect of layering near and outer surface on the heat load.

قيم البحث

اقرأ أيضاً

Providing thermal insulation to systems at very low temperature from surroundings, involves blocking the transport of thermal energy regular or enhanced, taking place through radiative, conductive and convective processes. For instance, the enhanceme nt of radiative heat transport that takes place by infra red or far infra red light at low temperature is due to diffractive propagation. The wavelength of light in this part of the spectrum usually lie in the range of mm to cms. Hence it can get bent across an obstacle while propagating forward. Apart from radiative, the convective and conductive processes also get affected due to appearance of non linearities in the modes of lattice vibrations and anomalies in material transport due to the appearance of vorticity and turbulence in the intervening media. The Multilayer insulation technique has offered a robust thermal protective mechanism to provide proper insulation to the cold walls of the cryostats from the heat of the surroundings. This work is focused on the estimation of performance and efficiency of the MLI technique as well as exploration of its versatile applicability. Three different spacer materials such as Dacron, Glass tissue, and Silk net with radiation shields are selected for the intervening medium in the present study. This article explores the thermal performance of MLI system by changing the physical parameters, varying the geometry of the radiation shields perforation styles of radiation shields and by analyzing the effect of arrangement of radiation shields on the conduction heat load. This analysis is concluded by studying the possibility of using MLI technique in the health sector by reducing the evaporation rate of liquid Oxygen during pandemic situations e.g. in COVID19.
The external shell of the CUORE cryostat is a large cryogen-free system designed to host the dilution refrigerator and the bolometers of the CUORE experiment in a low radioactivity environment. The three vessels that form the outer shell were produce d and delivered to the Gran Sasso underground Laboratories in July 2012. In this paper, we describe the production techniques and the validation tests done at the production site in 2012.
High pressure gas time projection chambers (HPGTPCs) are made with a variety of materials, many of which have not been well characterized in high pressure noble gas environments. As HPGTPCs are scaled up in size toward ton-scale detectors, assemblies become larger and more complex, creating a need for detailed understanding of how structural supports and high voltage insulators behave. This includes the identification of materials with predictable mechanical properties and without surface charge accumulation that may lead to field deformation or sparking. This paper explores the mechanical and electrical effects of high pressure gas environments on insulating polymers PTFE, HDPE, PEEK, POM and UHMW in Argon and Xenon, including studying absorption, swelling and high voltage insulation strength.
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much o f the unexplored neutrino mass range with $mathcal{O}({rm eV})$ resolution. A lower bound of $m( u_e) gtrsim 9(0.1), {rm meV}$ is set by observations of neutrino oscillations, while the KATRIN Experiment - the current-generation tritium beta-decay experiment that is based on Magnetic Adiabatic Collimation with an Electrostatic (MAC-E) filter - will achieve a sensitivity of $m( u_e) lesssim 0.2,{rm eV}$. The CRES technique aims to avoid the difficulties in scaling up a MAC-E filter-based experiment to achieve a lower mass sensitivity. In this paper we review the current status of the CRES technique and describe Project 8, a phased absolute neutrino mass experiment that has the potential to reach sensitivities down to $m( u_e) lesssim 40,{rm meV}$ using an atomic tritium source.
In this work we study the performance of silicon photomultiplier (SiPM) light sensors after exposure to the JULIC cyclotron proton beam, of energy $sim$ 39 MeV, relative to their performance before exposure. The SiPM devices used in this study show a significant change in their behavior and downward shift of their breakdown voltage by as much as $sim$ 0.4$pm$0.1 V. Single photon measurements appear to be no longer possible for the SiPMs under study after exposure to a dose of $sim$ 0.2 Gy (corresponding to an integrated proton flux of $sim$$phi_{p}$=1.06x10$^{8}$ p/cm$^{2}$). No visible damage to the surface of the devices was caused by the exposure.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا