For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at |z| = 3.5 m and covering the region 2.4 < |{eta}| < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 {mu}m thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3x1.3 mm2 and arrays with 2x2 pads with a surface area of 2x2 mm^2 or 3x3 mm^2 each and different implant doses of the p+ multiplication layer. They are obtained from data collected during a beam test campaign in Autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few {mu}m. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3x1.3 mm^2 have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfill the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.



قيم البحث

اقرأ أيضاً

84 - M. Jadhav 2020
This paper presents results that take a critical step toward proving 10 ps timing resolutions feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 micro-m and 50 micro-m are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 micro-m thick LGADs at -30 degree celsius with a precision of 14.3 ps (uncertainty 1.5 ps).
266 - Tao Yang , Kewei Wu , Mei Zhao 2021
We report a precise TCAD simulation for low gain avalanche detector (LGAD) with calibration by secondary ion mass spectroscopy (SIMS). The radiation model - LGAD Radiation Damage Model (LRDM) combines local acceptor degeneration with global deep ener gy levels is proposed. The LRDM could predict the leakage current level and the behavior of capacitance for irradiated LGAD sensor at -30 $^{circ}$C after irradiation fluence $rm Phi_{eq}=2.5 times 10^{15} ~n_{eq}/cm^{2}$.
The High-Granularity Timing Detector is a detector proposed for the ATLAS Phase II upgrade. The detector, based on the Low-Gain Avalanche Detector (LGAD) technology will cover the pseudo-rapidity region of $2.4<|eta|<4.0$ with two end caps on each si de and a total area of 6.4 $m^2$. The timing performance can be improved by implanting an internal gain layer that can produce signal with a fast rising edge, which improve significantly the signal-to-noise ratio. The required average timing resolution per track for a minimum-ionising particle is 30 ps at the start and 50 ps at the end of the HL-LHC operation. This is achieved with several layers of LGAD. The innermost region of the detector would accumulate a 1 MeV-neutron equivalent fluence up to $2.5 times 10^{15} cm^{-2}$ before being replaced during the scheduled shutdowns. The addition of this new detector is expected to play an important role in the mitigation of high pile-up at the HL-LHC. The layout and performance of the vario
Low Gain Avalanche Detector (LGAD) technology has been used to design and construct prototypes of time-zero detector for experiments utilizing proton and pion beams with High Acceptance Di-Electron Spectrometer (HADES) at GSI Darmstadt, Germany. LGAD properties have been studied with proton beams at the COoler SYnchrotron (COSY) facility in Julich, Germany. We have demonstrated that systems based on a prototype LGAD operated at room temperature and equipped with leading-edge discriminators reach a time precision below 50 ps. The application in the HADES, experimental conditions, as well as the test results obtained with proton beams are presented.
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95pm0.05,%$, while the intrinsic spatial resolutions are $4.80pm0.25,mu mathrm{m}$ and $7.99pm0.21,mu mathrm{m}$ along the $100,mu mathrm{m}$ and $150,mu mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.