ترغب بنشر مسار تعليمي؟ اضغط هنا

Strong reduction of the effective radiation length in an axially oriented scintillator crystal

53   0   0.0 ( 0 )
 نشر من قبل Laura Bandiera
 تاريخ النشر 2018
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We measured a considerable increase of the emitted radiation by 120 GeV/c electrons in an axially oriented lead tungstate scintillator crystal, if compared to the case in which the sample was not aligned with the beam direction. This enhancement resulted from the interaction of particles with the strong crystalline electromagnetic field. The data collected at the external lines of CERN SPS were critically compared to Monte Carlo simulations based on the Baier Katkov quasiclassical method, highlighting a reduction of the scintillator radiation length by a factor of five in case of beam alignment with the [001] crystal axes. The observed effect opens the way to the realization of compact electromagnetic calorimeters/detectors based on oriented scintillator crystals in which the amount of material can be strongly reduced with respect to the state of the art. These devices could have relevant applications in fixed-target experiments as well as in satellite-borne gamma-telescopes.

قيم البحث

اقرأ أيضاً

We present new results on the radiopurity of a 3.4-kg NaI(Tl) crystal scintillator operated in the SABRE proof-of-principle detector setup. The amount of potassium contamination, determined by the direct counting of radioactive $^{40}$K, is found to be $2.2pm1.5$ ppb, lowest ever achieved for NaI(Tl) crystals. With the active veto, the average background rate in the crystal in the 1-6 keV energy region-of-interest (ROI) is $1.20pm0.05$ counts/day/kg/keV, which is a breakthrough since the DAMA/LIBRA experiment. Our background model indicates that the rate is dominated by $^{210}$Pb and that about half of this contamination is located in the PTFE reflector. We discuss ongoing developments of the crystal manufacture aimed at the further reduction of the background, including data from purification by zone refining. A projected background rate lower than $sim$0.2 counts/day/kg/keV in the ROI is within reach. These results represent a benchmark for the development of next-generation NaI(Tl) detector arrays for the direct detection of dark matter particles.
Multilayer insulation (MLI) is an important technique for the reduction of radiation heat load in cryostats. The present work is focused on investigation for the selection of suitable reflective layer and spacer material in MLI systems. In our analys is, we have selected perforated double-Aluminized Mylar (DAM) with Dacron, unperforated DAM with Silk-net and perforated DAM with Glass-tissue for their evaluation as the reflective layer as well as spacer materials in MLI technique. Current work would discuss the calculation of the effect of layer density and the number of layers on the heat load. Knowing the key parameters of MLI, we have compared the heat load generation in spherical as well as cylindrical cryostats and the effect of layering near and outer surface on the heat load.
329 - H.S. Kim , S.Y. Kim , J.H. Choi 2016
We present an in-situ method of measuring the relative attenuation length of gadolinium-loaded liquid scintillator in the RENO detectors using radioactive source calibration data without requiring any PMT performance model. We observed the degradatio n of the attenuation length of the gadolinium-loaded liquid scintillator in the RENO detectors by ~50% over a period of about 4 years.
This paper discusses the effects of radiation damage to SiPMs on the performances of plastic scintillator counters with series-connected SiPM readout, focusing on timing measurements. The performances of a counter composed of a $120 times 40 times5~m athrm{mm}^3$ scintillator tile read out by two sets of six SiPMs from AdvanSiD connected in series attached on the short sides are presented, for different combinations of SiPMs at various levels of irradiation. Firstly, six SiPMs were equally irradiated with electrons from $^{90}$Sr sources up to a fluence of $Phi_mathrm{e^-}approx 3 times 10^{12}~mathrm{cm}^{-2}$. The timing resolution of the counter gradually deteriorated by the increase in dark current. The dark current and the deterioration were reduced when the counter was cooled from 30$^circ$C to 10$^circ$C. Secondly, 33 SiPMs were irradiated with reactor neutrons. The characteristics of counters read out by series-connected SiPMs with non-uniform damage levels, were investigated. The signal pulse height, the time response, and the timing resolution depend on the hit position in the counter, when SiPMs irradiation is not uniform.
428 - P. Belli 2011
A strontium iodide crystal doped by europium (SrI2(Eu)) was produced by using the Stockbarger growth technique. The crystal was subjected to a characterization that includes relative photoelectron output and energy resolution for gamma quanta. The in trinsic radioactivity of the SrI2(Eu) crystal scintillator was tested both by using it as scintillator at sea level and by ultra-low background HPGe gamma spectrometry deep underground. The response of the SrI2(Eu) detector to alpha particles (alpha/beta ratio and pulse shape) was estimated by analysing the 226Ra internal trace contamination of the crystal. We have measured: alpha/beta=0.55 at E_alpha=7.7 MeV, and no difference in the time decay of the scintillation pulses induced by alpha particles and gamma quanta. The application of the obtained results in the search for the double electron capture and electron capture with positron emission in 84Sr has been investigated at a level of sensitivity: T_1/2 sim 10^{15}-10^{16} yr. The results of these studies demonstrate the potentiality of this material for a variety of scintillation applications, including low-level counting experiments.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا