ترغب بنشر مسار تعليمي؟ اضغط هنا

The Miniature X-ray Solar Spectrometer (MinXSS) CubeSats: spectrometer characterization techniques, spectrometer capabilities, and solar science objectives

155   0   0.0 ( 0 )
 نشر من قبل Amir Caspi
 تاريخ النشر 2016
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Miniature X-ray Solar Spectrometer (MinXSS) are twin 3U CubeSats. The first of the twin CubeSats (MinXSS-1) launched in December 2015 to the International Space Station for deployment in mid-2016. Both MinXSS CubeSats utilize a commercial off the shelf (COTS) X-ray spectrometer from Amptek to measure the solar irradiance from 0.5 to 30 keV with a nominal 0.15 keV FWHM spectral resolution at 5.9 keV, and a LASP-developed X-ray broadband photometer with similar spectral sensitivity. MinXSS design and development has involved over 40 graduate students supervised by professors and professionals at the University of Colorado at Boulder. The majority of previous solar soft X-ray measurements have been either at high spectral resolution with a narrow bandpass or spectrally integrating (broadband) photometers. MinXSS will conduct unique soft X-ray measurements with moderate spectral resolution over a relatively large energy range to study solar active region evolution, solar flares, and the effects of solar soft X-ray emission on Earths ionosphere. This paper focuses on the X-ray spectrometer instrument characterization techniques involving radioactive X-ray sources and the National Institute for Standards and Technology (NIST) Synchrotron Ultraviolet Radiation Facility (SURF). Spectrometer spectral response, spectral resolution, response linearity are discussed as well as future solar science objectives.

قيم البحث

اقرأ أيضاً

The Spectrometer/Telescope for Imaging X-rays (STIX) will look at solar flares across the hard X-ray window provided by the Solar Orbiter cluster. Similarly to the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), STIX is a visibility-ba sed imaging instrument, which will ask for Fourier-based image reconstruction methods. However, in this paper we show that, as for RHESSI, also for STIX count-based imaging is possible. Specifically, here we introduce and illustrate a mathematical model that mimics the STIX data formation process as a projection from the incoming photon flux into a vector made of 120 count components. Then we test the reliability of Expectation Maximization for image reconstruction in the case of several simulated configurations typical of flare morphology.
The MESSENGER spacecraft conducted its first flyby of Mercury on 14th January 2008, followed by two subsequent encounters on 6th October 2008 and 29th September 2009, prior to Mercury orbit insertion on 18th March 2011. We have reviewed MESSENGER fli ght telemetry and X-ray Spectrometer observations from the first two encounters, and correlate several prominent features in the data with the presence of astrophysical X-ray sources in the instrument field of view. We find that two X-ray peaks attributed in earlier work to the detection of suprathermal electrons from the Mercury magnetosphere, are likely to contain a significant number of events that are of astrophysical origin. The intensities of these two peaks cannot be explained entirely on the basis of astrophysical sources, and we support the previous suprathermal explanation but suggest that the electron fluxes derived in those studies be revised to correct for a significant astrophysical signal.
In this Astro2020 APC White Paper, we describe a Small Explorer (SMEX) mission concept called the Compton Spectrometer and Imager. COSI is a Compton telescope that covers the bandpass often referred to as the MeV Gap because it is the least explored region of the whole electromagnetic spectrum. COSI provides a significant improvement in sensitivity along with high-resolution spectroscopy, enabling studies of 511 keV electron-positron annihilation emission and measurements of several radioactive elements that trace the Galactic history of supernovae. COSI also measures polarization of gamma-ray bursts (GRBs), accreting black holes, and pulsars as well as detecting and localizing multimessenger sources. In the following, we describe the COSI science, the instrument, and its capabilities. We highlight many Astro2020 science WPs that describe the COSI science in depth.
The Spectral Imaging of the Coronal Environment (SPICE) instrument is a high-resolution imaging spectrometer operating at extreme ultraviolet (EUV) wavelengths. In this paper, we present the concept, design, and pre-launch performance of this facilit y instrument on the ESA/NASA Solar Orbiter mission. The goal of this paper is to give prospective users a better understanding of the possible types of observations, the data acquisition, and the sources that contribute to the instruments signal. The paper discusses the science objectives, with a focus on the SPICE-specific aspects, before presenting the instruments design, including optical, mechanical, thermal, and electronics aspects. This is followed by a characterisation and calibration of the instruments performance. The paper concludes with descriptions of the operations concept and data processing. The performance measurements of the various instrument parameters meet the requirements derived from the missions science objectives. The SPICE instrument is ready to perform measurements that will provide vital contributions to the scientific success of the Solar Orbiter mission.
We present the result of the in-flight calibration of the effective area of the Soft X-ray Spectrometer (SXS) onboard the Hitomi X-ray satellite using an observation of the Crab nebula. We corrected for the artifacts when observing high count rate so urces with the X-ray microcalorimeter. We then constructed a spectrum in the 0.5-20 keV band, which we modeled with a single power-law continuum attenuated by an interstellar extinction. We evaluated the systematic uncertainty upon the spectral parameters by various calibration items. In the 2-12 keV band, the SXS result is consistent with the literature values in flux (2.20 $pm$ 0.08) $times$10$^{-8}$ erg s$^{-1}$ cm$^{-2}$ with a 1$sigma$ statistical uncertainty) but is softer in the power-law index (2.19 $pm$ 0.11). The discrepancy is attributable to the systematic uncertainty of about $+$6/$-$7% and $+$2/$-$5% respectively for the flux and the power-law index. The softer spectrum is affected primarily by the systematic uncertainty of the Dewar gate valve transmission and the event screening.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا