Integral neutronics experiments have been investigated at Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS) in order to validate evaluated nuclear data related to the design of Chinese Initiative Accelerator Driven Systems (CIADS). In present paper, the accuracy of evaluated nuclear data for Tungsten has been examined by comparing measured leakage neutron spectra with calculated ones. Leakage neutron spectra from the irradiation of D-T neutrons on Tungsten slab sample were experimentally measured at 60$^{circ}$ and 120$^{circ}$ by using a time-of-flight method. Theoretical calculations are carried out by Monte Carlo neutron transport code MCNP-4C with evaluated nuclear data of the ADS-2.0, ENDF/B-VII.0, ENDF/B-VII.1, JENDL-4.0 and CENDL-3.1 libraries. From the comparisons, it is found that the calculations with ADS-2.0 and ENDF/B-VII.1 give good agreements with the experiments in the whole energy regions at 60$^{circ}$, while a large discrepancy is observed at 120$^{circ}$ in the elastic scattering peak, caused by a slight difference in the oscillation pattern of the elastic angular distribution at angles larger than 20$^{circ}$. However, the calculated spectra using data from ENDF/B-VII.0, JENDL-4.0 and CENDL-3.1 libraries showed larger discrepancies with the measured ones, especially around 8.5-13.5 MeV. Further studies are presented for these disagreements.



قيم البحث

اقرأ أيضاً

An accurate description of interactions between thermal neutrons (below 4 eV) and materials is key to simulate the transport of neutrons in a wide range of applications such as criticality-safety, reactor physics, compact accelerator-driven neutron s ources, radiological shielding or nuclear instrumentation, just to name a few. While the Monte Carlo transport code Geant4 was initially developed to simulate particle physics experiments, %-with a large emphasis given on modeled cross-sections for all known particles at all conceivable energies-, its use has spread to neutronics applications, requiring evaluated cross-sections for neutrons and gammas between $0$ and $20$ MeV (the so-called neutron High Precision -HP- package), as well as a proper offline or on-the-flight treatment of these cross-sections. In this paper we will point out limitations affecting Geant4 (version 10.07.p01) thermal neutron treatment and associated nuclear data libraries, by using comparisons with the reference Monte Carlo neutron transport code tripoli, version 11, and we will present the results of various modifications of the Geant4 neutron-HP package, required to overcome these limitations. Also, in order to broaden the support of nuclear data libraries compatible with Geant4, a nuclear processing tool has been developed and validated allowing the use of the code together with ENDF-BVIII.0 and JEFF-3.3 libraries for example. These changes should be taken into account in an upcoming Geant4 release.
Diamonds are very promising candidates for the neutron diagnostics in harsh environments such as fusion reactor. In the first place this is because of their radiation hardness, exceeding that of Silicon by an order of magnitude. Also, in comparison t o the standard on-line neutron diagnostics (fission chambers, silicon based detectors, scintillators), diamonds are less sensitive to $gamma$ rays, which represent a huge background in fusion devices. Finally, their low leakage current at high temperature suppresses the detector intrinsic noise. In this talk a CVD diamond based detector has been proposed for the measurement of the 14 MeV neutrons from D-T fusion reaction. The detector was arranged in a proton recoil telescope configuration, featuring a plastic converter in front of the sensitive volume in order to induce the (n,p) reaction. The segmentation of the sensitive volume, achieved by using two crystals, allowed to perform measurements in coincidence, which suppressed the neutron elastic scattering background. A preliminary prototype was assembled and tested at FNG (Frascati Neutron Generator, ENEA), showing promising results regarding efficiency and energy resolution.
A dominant contribution to ECal resolution at high energy (eg. 100 GeV) comes from leakage beyond the containment of the calorimeter. We have studied the leakage energy for the SiD silicon-tungsten ECal and developed a neural network algorithm for es timating the leakage energy and correcting the energy measurement. The SiD TDR design calls for 20 thin 2.5 mm tungsten layers followed by 10 thick 5.0 mm tungsten layers. We have investigated the impact on the leakage energy of a reduced number of layers, and the ability of an optimized neutral network analysis to correct for the leakage with a reduced number of layers, and reduced material thickness. Reducing layer numbers is motivated by cost containment.
We analyze the spin flip loss for ultracold neutrons in magnetic bottles of the type used in experiments aiming at a precise measurement of the neutron lifetime, extending the one-dimensional field model used previously by Steyerl $textit{et al.}$ [P hys.Rev.C $mathbf{86}$, 065501 (2012)] to two dimensions for cylindrical multipole fields. We also develop a general analysis applicable to three dimensions. Here we apply it to multipole fields and to the bowl-type field configuration used for the Los Alamos UCN$tau$ experiment. In all cases considered the spin flip loss calculated exceeds the Majorana estimate by many orders of magnitude but can be suppressed sufficiently by applying a holding field of appropriate magnitude to allow high-precision neutron lifetime measurements, provided other possible sources of systematic error are under control.
We present the results of neutron detection in a laser plasma experiment with a CD$_2$ nanowire target. A hybrid semiconductor pixel detector Timepix3 covered with neutron converters was used for the detection of neutrons. D-D fusion neutrons were de tected in a polyethylene converter through recoiled protons. Both the energy of recoiled protons and the time-of-flight of neutrons (and thus their energy) were determined. We report $(2.4 pm 1.8) times 10^7$ neutrons generated for 1~J of incoming laser energy. Furthermore, we proved that Timepix3 is suitable for difficult operational conditions in laser experiments.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا