ترغب بنشر مسار تعليمي؟ اضغط هنا

Energy measurement and fragment identification using digital signals from partially depleted Si detectors

78   0   0.0 ( 0 )
 نشر من قبل Alessandro Olmi
 تاريخ النشر 2014
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the DE-E technique or Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the DE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector whose doping uniformity is not good enough for isotopic identification at full depletion.

قيم البحث

اقرأ أيضاً

A new generation of cryogenic light detectors exploiting Neganov-Luke effect to enhance the thermal signal has been used to detect the Cherenkov light emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism a high significance event-by-event discrimination between alpha and beta/gamma interactions at the $^{130}$Te neutrino-less double beta decay Q-value - (2527.515 $pm$ 0.013) keV - has been demonstrated. This measurement opens the possibility of drastically reducing the background in cryogenic experiments based on TeO$_{2}$.
A series of test experiments on three different Si-based neutron detectors, namely a 1-d 128 channel, 0.5 mm space resolution Si microstrip sensor coupled to natural Gd converter, a medium size ? 1 cm2 PIN diode coupled to nGd2O3 or 157Gd2O3 converte rs, and a SiPM photomultiplier coupled to neutron scintillators, are presented to show the performances of this class of devices for thermal neutron detection. A pulse shape analysis method, designed to improve the performance of these devices by an optimized discrimination of the neutron signals from noise and background radiation, is proposed, described and tested. This study is aimed to real time applications and single event storage of the neutron information in time of flight instrumentation.
225Ac is a valuable medical radionuclide for targeted alpha therapy, but 227Ac is an undesirable byproduct of an accelerator-based synthesis method under investigation. Sufficient detector sensitivity is critical for quantifying the trace impurity of 227Ac, with the 227Ac/225Ac activity ratio predicted to be approximately 0.15% by end-of-bombardment (EOB). Superconducting transition edge sensor (TES) microcalorimeters offer high resolution energy spectroscopy using the normal-to-superconducting phase transition to measure small change in temperature. By embedding 225Ac production samples in a gold foil thermally coupled to a TES microcalorimeter we can measure the decay energies of the radionuclides embedded with high resolution and efficiency. This technique, known as decay energy spectroscopy (DES), collapses several peaks from alpha decays into single Q-value peaks. In practice there are more complex factors in the interpretation of data using DES, which we will discuss herein. Using this technique we measured the EOB 227Ac impurity to be (0.142 +/- 0.005)% for a single production sample. This demonstration has shown that DES can distinguish closely related isotopic features and is a useful tool for quantitative measures.
Next generation calorimetric experiments for the search of rare events rely on the detection of tiny amounts of light (of the order of 20 optical photons) to discriminate and reduce background sources and improve sensitivity. Calorimetric detectors a re the simplest solution for photon detection at cryogenic (mK) temperatures. The development of silicon based light detectors with enhanced performance thanks to the use of the Neganov-Luke effect is described. The aim of this research line is the production of high performance detectors with industrial-grade reproducibility and reliability.
This paper presents an absolute X-ray photon energy measurement method that uses a Bond diffractometer. The proposed system enables the prompt and rapid in-situ measurement of photon energies in a wide energy range. The diffractometer uses a referenc e silicon single crystal plate and a highly accurate angle encoder called SelfA. We evaluate the performance of the system by repeatedly measuring the energy of the first excited state of the potassium-40 nuclide. The excitation energy is determined as 29829.39(6) eV. It is one order of magnitude more precise than the previous measurement. The estimated uncertainty of the photon energy measurement was 0.7 ppm as a standard deviation and the maximum observed deviation was 2 ppm.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا