ترغب بنشر مسار تعليمي؟ اضغط هنا

PAOLO: a Polarimeter Add-On for the LRS Optics at a Nasmyth focus of the TNG

56   0   0.0 ( 0 )
 نشر من قبل Stefano Covino
 تاريخ النشر 2013
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

We describe a new polarimetric facility available at the Istituto Nazionale di AstroFisica / Telescopio Nazionale Galileo at La Palma, Canary islands. This facility, PAOLO (Polarimetric Add-On for the LRS Optics), is located at a Nasmyth focus of an alt-az telescope and requires a specific modeling in order to remove the time- and pointing position-dependent instrumental polarization. We also describe the opto-mechanical structure of the instrument and its calibration and present early examples of applications.

قيم البحث

اقرأ أيضاً

POLICAN is a near-infrared imaging linear polarimeter developed for the Cananea Near-infrared Camera (CANICA) at the 2.1m telescope of the Guillermo Haro Astrophysical Observatory (OAGH) located in Cananea, Sonora, Mexico. POLICAN is mounted ahead of CANICA and consist of a rotating super-achromatic 1-2.7 micron half-wave plate (HWP) as the modulator and a fixed wire-grid polarizer as the analyzer. CANICA has a 1024 x 1024 HgCdTe detector with a plate scale of 0.32 arcsec/pixel and provides a field of view of 5.5 x 5.5 arcmin^2. The polarimetric observations are carried out by modulating the incoming light through different steps of half-wave plate angles 0, 22.5, 45, 67.5 deg, to establish linear Stokes parameters (I, Q, and U). Image reduction consists of dark subtraction, polarimetric flat fielding, and sky subtraction. The astrometry and photometric calibrations are performed using the publicly available data from the Two Micron All Sky Survey. Polarimetric calibration includes observations of globular clusters and polarization standards available in the literature. Analysis of multiple observations of globular clusters yielded an instrumental polarization of 0.51%. Uncertainties in polarization range from 0.1% to 10% from the brightest 7 mag to faintest 16 mag stars. The polarimetric accuracy achieved is better than 0.5% and the position angle errors less than 5 deg for stars brighter than 13 mag in H-band. POLICAN is mainly being used to study the scattered polarization and magnetic fields in and around star-forming regions of the interstellar medium.
A detection of curl-type ($B$-mode) polarization of the primary CMB would be direct evidence for the inflationary paradigm of the origin of the Universe. The BICEP/Keck Array (BK) program targets the degree angular scales, where the power from primor dial $B$-mode polarization is expected to peak, with ever-increasing sensitivity and has published the most stringent constraints on inflation to date. BICEP Array (BA) is the Stage-3 instrument of the BK program and will comprise four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz with a combined 32,000+ detectors; such wide frequency coverage is necessary for control of the Galactic foregrounds, which also produce degree-scale $B$-mode signal. The 30/40 GHz receiver is designed to constrain the synchrotron foreground and has begun observing at the South Pole in early 2020. By the end of a 3-year observing campaign, the full BICEP Array instrument is projected to reach $sigma_r$ between 0.002 and 0.004, depending on foreground complexity and degree of removal of $B$-modes due to gravitational lensing (delensing). This paper presents an overview of the design, measured on-sky performance and calibration of the first BA receiver. We also give a preview of the added complexity in the time-domain multiplexed readout of the 7,776-detector 150 GHz receiver.
We describe the conceptual design of the spectrograph opto-mechanical concept for the SuMIRe Prime Focus Spectrograph (PFS) being developed for the SUBARU telescope. The SuMIRe PFS will consist of four identical spectrographs, each receiving 600 fibe rs from a 2400 fiber robotic positioner at the prime focus. Each spectrograph will have three channels covering in total, a wavelength range from 380 nm to 1300 nm. The requirements for the instrument are summarized in Section 1. We present the optical design and the optical performance and analysis in Section 2. Section 3 introduces the mechanical design, its requirements and the proposed concepts. Finally, the AIT phases for the Spectrograph System are described in Section 5.
Observing at the VLT Coude focus can boost the collecting area by combining light from multiple VLT unit telescopes (UTs; albeit with some losses in the light train). An instrument at the Coude enjoys significant operational flexibility advantage: it can be attached to any available UT and the extra instrument can help to match better the observing constraints with the current conditions. With modifications to the existing train it can even observe in parallel with ESPRESSO with different UTs. Here we consider a general purpose VLT Coude fiber-fed low-resolution facility spectrograph - provisionally named Cappuccino - suitable for rapid follow up and characterization of faint transients, for late-stage monitoring of transients and for rapid classification under poor conditions or during twilight. Like any instrument of its class, Cappuccino can be used to address diverse set of science questions. The building cost can be reduced greatly if it is based - with modest changes - on existing hardware.
The balloon-borne LSPE mission is optimized to measure the linear polarization of the Cosmic Microwave Background at large angular scales. The Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed of 3 arrays of multi-mode bol ometers cooled at 0.3K, with optical components and filters cryogenically cooled below 4K to reduce the background on the detectors. Polarimetry is achieved by means of large rotating half-wave plates and wire-grid polarizers in front of the arrays. The polarization modulator is the first component of the optical chain, reducing significantly the effect of instrumental polarization. In SWIPE we trade angular resolution for sensitivity. The diameter of the entrance pupil of the refractive telescope is 45 cm, while the field optics is optimized to collect tens of modes for each detector, thus boosting the absorbed power. This approach results in a FWHM resolution of 1.8, 1.5, 1.2 degrees at 95, 145, 245 GHz respectively. The expected performance of the three channels is limited by photon noise, resulting in a final sensitivity around 0.1-0.2 uK per beam, for a 13 days survey covering 25% of the sky.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا