ترغب بنشر مسار تعليمي؟ اضغط هنا

Near Infrared Angular Diameters of a few AGB variables by Lunar Occultations

60   0   0.0 ( 0 )
 نشر من قبل Tapas Baug
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The uniform disk (UD) angular diameter measurements of two oxygen-rich Mira variables (AW Aur and BS Aur) and three semiregular (SRb) variables (GP Tau, RS Cap, RT Cap), in near Infrared K-band (2.2 micron) by lunar occultation observations are reported. UD angular diameters of the two Miras and one SRV are first time measurements. In addition a method of predicting angular diameters from (V-K) colour is discussed and applied to the five sources. The effect of mass-loss enhancing measured K-band diameters is examined for Miras using (K-[12]) colour excess as an index. In our sample the measured angular diameter of one of the Miras (BS Aur) is found enhanced by nearly 40% compared to its expected value, possibly due to mass loss effects leading to formation of a circumstellar shell.

قيم البحث

اقرأ أيضاً

We report the first-time use of the Aqueye+ and Iqueye instruments to record lunar occultation events. High-time resolution recordings in different filters have been acquired for several occultations taken from January 2016 through January 2018 with Aqueye+ at the Copernicus telescope and Iqueye at the Galileo telescope in Asiago, Italy. Light curves with different time bins were calculated in post-processing and analyzed using a least-square model-dependent method. A total of nine occultation light curves were recorded, including one star for which we could measure for the first time the size of the chromosphere ($mu$ Psc) and one binary star for which discrepant previous determinations existed in the literature (SAO 92922). A disappearance of Alf Tau shows an angular diameter in good agreement with literature values. The other stars were found to be unresolved, at the milliarcsecond level. We discuss the unique properties of Aqueye+ and Iqueye for this kind of observations, namely the simultaneous measurement in up to four different filters thanks to pupil splitting, and the unprecedented time resolution well exceeding the microsecond level. This latter makes Aqueye+ and Iqueye suitable to observe not just occultations by the Moon, but also much faster events such as e.g. occultations by artificial screens in low orbits. We provide an outlook of future possible observations in this context.
75 - W. Benbow , R. Bird , A. Brill 2019
The angular size of a star is a critical factor in determining its basic properties. Direct measurement of stellar angular diameters is difficult: at interstellar distances stars are generally too small to resolve by any individual imaging telescope. This fundamental limitation can be overcome by studying the diffraction pattern in the shadow cast when an asteroid occults a star, but only when the photometric uncertainty is smaller than the noise added by atmospheric scintillation. Atmospheric Cherenkov telescopes used for particle astrophysics observations have not generally been exploited for optical astronomy due to the modest optical quality of the mirror surface. However, their large mirror area makes them well suited for such high-time-resolution precision photometry measurements. Here we report two occultations of stars observed by the VERITAS Cherenkov telescopes with millisecond sampling, from which we are able to provide a direct measurement of the occulted stars angular diameter at the $leq0.1$ milliarcsecond scale. This is a resolution never achieved before with optical measurements and represents an order of magnitude improvement over the equivalent lunar occultation method. We compare the resulting stellar radius with empirically derived estimates from temperature and brightness measurements, confirming the latter can be biased for stars with ambiguous stellar classifications.
We present the Mid-infrared stellar Diameters and Fluxes compilation Catalogue (MDFC) dedicated to long-baseline interferometry at mid-infrared wavelengths (3-13 mum). It gathers data for half a million stars, i.e. nearly all the stars of the Hipparc os-Tycho catalogue whose spectral type is reported in the SIMBAD database. We cross-match 26 databases to provide basic information, binarity elements, angular diameter, magnitude and flux in the near and mid-infrared, as well as flags that allow us to identify the potential calibrators. The catalogue covers the entire sky with 465 857 stars, mainly dwarfs and giants from B to M spectral types closer than 18 kpc. The smallest reported values reach 0.16 muJy in L and 0.1 muJy in N for the flux, and 2 microarcsec for the angular diameter. We build 4 lists of calibrator candidates for the L- and N-bands suitable with the Very Large Telescope Interferometer (VLTI) sub- and main arrays using the MATISSE instrument. We identify 1 621 candidates for L and 44 candidates for N with the Auxiliary Telescopes (ATs), 375 candidates for both bands with the ATs, and 259 candidates for both bands with the Unit Telescopes (UTs). Predominantly cool giants, these sources are small and bright enough to belong to the primary lists of calibrator candidates. In the near future, we plan to measure their angular diameter with 1% accuracy.
In the current era of Gaia and large, high signal to noise stellar spectroscopic surveys, there is an unmet need for a reliable library of fundamentally calibrated stellar effective temperatures based on accurate stellar diameters. Here we present a set of precision diameters and temperatures for a sample of 6 dwarf, 5 sub-giant, and 5 giant stars observed with the PIONIER beam combiner at the VLTI. Science targets were observed in at least two sequences with five unique calibration stars each for accurate visibility calibration and to reduce the impact of bad calibrators. We use the standard PIONIER data reduction pipeline, but bootstrap over interferograms, in addition to employing a Monte-Carlo approach to account for correlated errors by sampling stellar parameters, limb darkening coefficients, and fluxes, as well as predicted calibrator angular diameters. The resulting diameters were then combined with bolometric fluxes derived from broadband Hipparcos-Tycho photometry and MARCS model bolometric corrections, plus parallaxes from Gaia to produce effective temperatures, physical radii, and luminosities for each star observed. Our stars have mean angular diameter and temperatures uncertainties of 0.8% and 0.9% respectively, with our sample including diameters for 10 stars with no pre-existing interferometric measurements. The remaining stars are consistent with previous measurements, with the exception of a single star which we observe here with PIONIER at both higher resolution and greater sensitivity than was achieved in earlier work.
81 - V.F. Braga 2018
We provide homogeneous optical (UBVRI) and near-infrared (JHK) time series photometry for 254 cluster (omega Cen, M4) and field RR Lyrae (RRL) variables. We ended up with more than 551,000 measurements. For 94 fundamental (RRab) and 51 first overtone s (RRc) we provide a complete optical/NIR characterization (mean magnitudes, luminosity amplitudes, epoch of the anchor point). The NIR light curves of these variables were adopted to provide new and accurate light-curve templates for both RRc (single period bin) and RRab (three period bins) variables. The templates for the J and the H band are newly introduced, together with the use of the pulsation period to discriminate among the different RRab templates. To overcome subtle uncertainties in the fit of secondary features of the light curves we provide two independent sets of analytical functions (Fourier series, Periodic Gaussian functions). The new templates were validated by using 26 omega Cen and Bulge RRLs covering the four period bins. We found that the difference between the measured mean magnitude along the light curve and the mean magnitude estimated by using the template on a single randomly extracted phase point is better than 0.01 mag (sigma=0.04 mag). We also validated the template on variables for which at least three phase points were available, but without information on the phase of the anchor point. The accuracy of the mean magnitudes is ~0.01 mag (sigma=0.04 mag). The new templates were applied to the Large Magellanic Cloud (LMC) globular Reticulum and by using literature data and predicted PLZ relations we found true distance moduli of 18.47+-0.10+-0.03 mag (J) and 18.49+-0.09+-0.05 mag (K). We also used literature optical and mid-infrared data and we found a mean true distance modulus of 18.47+-0.02+-0.06 mag, suggesting that Reticulum is ~1 kpc closer than the LMC.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا