ترغب بنشر مسار تعليمي؟ اضغط هنا

Implementation of the readout system in the UFFO Slewing Mirror Telescope

295   0   0.0 ( 0 )
 نشر من قبل Jieun Kim
 تاريخ النشر 2011
  مجال البحث فيزياء
والبحث باللغة English




اسأل ChatGPT حول البحث

The Ultra-Fast Flash Observatory (UFFO) is a new space-based experiment to observe Gamma-Ray Bursts (GRBs). GRBs are the most luminous electromagnetic events in the universe and occur randomly in any direction. Therefore the UFFO consists of two telescopes; UFFO Burst Alert & Trigger Telescope (UBAT) to detect GRBs using a wide field-of-view (FOV), and a Slewing Mirror Telescope (SMT) to observe UV/optical events rapidly within the narrow, targeted FOV. The SMT is a Ritchey-Chretien telescope that uses a motorized mirror system and an Intensified Charge-Coupled Device (ICCD). When the GRB is triggered by the UBAT, the SMT receives the position information and rapidly tilts the mirror to the target. The ICCD start to take the data within a second after GRB is triggered. Here we give the details about the SMT readout electronics that deliver the data.



قيم البحث

اقرأ أيضاً

119 - S. Jeong , K. -B. Ahn , J. W. Nam 2011
The Ultra-Fast Flash Observatory-Pathfinder (UFFO-P) is to be launched onboard Lomonosov spacecraft in November 2011. It is to measure early UV/Optical photons from Gamma Ray Bursts (GRBs). Slewing Mirror Telescope (SMT) is one of two instruments des igned for detection of UV/Optical images of the GRBs. SMT is a Ritchey-Chretien telescope of 100 mm in diameter with a motorized slewing mirror at the entrance providing 17times17 arcmin2 in Field of View (FOV) and 4 arcsec in pixel resolution. Its sky coverage can be further expanded up to 35 degrees in FOV by tilting a motorized slewing mirror. All mirrors were fabricated to about RMS 0.02 waves in wave front error (WFE) and 84.7% (in average reflectivity) over 200nm~650nm range. SMT was aligned to RMS 0.05 waves in WFE (test wavelength 632.8nm). From the static gravity test result, SMT optics system is expected to survive during launch. The technical details of SMT assembly and laboratory performance test results are reported.
249 - G. W. Na , K. -B. Ahn , H. S. Choi 2011
The Ultra-Fast Flash Observatory (UFFO) Pathfinder is a payload on the Russian Lomonosov satellite, scheduled to be launched in November 2011. The Observatory is designed to detect early UV/Optical photons from Gamma-Ray Bursts (GRBs). There are two telescopes and one main data acquisition system: the UFFO Burst Alert & Trigger Telescope (UBAT), the Slewing Mirror Telescope (SMT), and the UFFO Data Acquisition (UDAQ) system. The UDAQ controls and manages the operation and communication of each telescope, and is also in charge of the interface with the satellite. It will write the data taken by each telescope to the NOR flash memory and sends them to the satellite via the Bus-Interface system (BI). It also receives data from the satellite including the coordinates and time of an external trigger from another payload, and distributes them to two telescopes. These functions are implemented in field programmable gates arrays (FPGA) for low power consumption and fast processing without a microprocessor. The UDAQ architecture, control of the system, and data flow will be presented.
This paper describes the design, implementation, and verification of a test-bed for determining the noise temperature of radio antennas operating between 400-800MHz. The requirements for this test-bed were driven by the HIRAX experiment, which uses a ntennas with embedded amplification, making system noise characterization difficult in the laboratory. The test-bed consists of two large cylindrical cavities, each containing radio-frequency (RF) absorber held at different temperatures (300K and 77K), allowing a measurement of system noise temperature through the well-known Y-factor method. The apparatus has been constructed at Yale, and over the course of the past year has undergone detailed verification measurements. To date, three preliminary noise temperature measurement sets have been conducted using the system, putting us on track to make the first noise temperature measurements of the HIRAX feed and perform the first analysis of feed repeatability.
In this contribution we describe the hardware, firmware and software components of the readout system of the MAGIC-II Cherenkov telescope on the Canary island La Palma. The PMT analog signals are transmitted by means of optical fibers from the MAGIC- II camera to the 80 m away counting house where they are routed to the new high bandwidth and fully programmable receiver boards (MONSTER), which convert back the signals from optical to electrical ones. Then the signals are split, one half provide the input signals for the level ONE trigger system while the other half is sent to the digitizing units. The fast Cherenkov pulses are sampled by low-power Domino Ring Sampler chips (DRS2) and temporarily stored in an array of 1024 capacitors. Signals are sampled at the ultra-fast speed of 2 GSample/s, which allows a very precise measurement of the signal arrival times in all pixels. They are then digitized with 12-bit resolution by an external ADC readout at 40 MHz speed. The Domino samplers are integrated in the newly designed mezzanines which equip a set of fourteen multi-purpose PULSAR boards. Finally, the data are sent through an S-LINK optical interface to a single computer. The entire DAQ hardware is controlled through a VME interface and steered by the slow control software program (MIR). The Data AcQuisition software program (DAQ) proceeds finally to the event building and data storage.
A continuously rotating half-wave plate (CRHWP) is a promising tool to improve the sensitivity to large angular scales in cosmic microwave background (CMB) polarization measurements. With a CRHWP, single detectors can measure three of the Stokes para meters, $I$, $Q$ and $U$, thereby avoiding the set of systematic errors that can be introduced by mismatches in the properties of orthogonal detector pairs. We focus on the implementation of CRHWPs in large aperture telescopes (i.e. the primary mirror is larger than the current maximum half-wave plate diameter of $sim$0.5 m), where the CRHWP can be placed between the primary mirror and focal plane. In this configuration, one needs to address the intensity to polarization ($I{rightarrow}P$) leakage of the optics, which becomes a source of 1/f noise and also causes differential gain systematics that arise from CMB temperature fluctuations. In this paper, we present the performance of a CRHWP installed in the POLARBEAR experiment, which employs a Gregorian telescope with a 2.5 m primary illumination pattern. The CRHWP is placed near the prime focus between the primary and secondary mirrors. We find that the $I{rightarrow}P$ leakage is larger than the expectation from the physical properties of our primary mirror, resulting in a 1/f knee of 100 mHz. The excess leakage could be due to imperfections in the detector system, i.e. detector non-linearity in the responsivity and time-constant. We demonstrate, however, that by subtracting the leakage correlated with the intensity signal, the 1/f noise knee frequency is reduced to 32 mHz ($ell sim$39 for our scan strategy), which is very promising to probe the primordial B-mode signal. We also discuss methods for further noise subtraction in future projects where the precise temperature control of instrumental components and the leakage reduction will play a key role.
التعليقات
جاري جلب التعليقات جاري جلب التعليقات
سجل دخول لتتمكن من متابعة معايير البحث التي قمت باختيارها
mircosoft-partner

هل ترغب بارسال اشعارات عن اخر التحديثات في شمرا-اكاديميا